A Hybrid Calibration Method for Aperture Synthesis Radiometers

被引:9
|
作者
Lu, Hailiang [1 ]
Li, Qingxia [1 ]
Jin, Rong [1 ]
Chen, Ke [1 ]
Li, Yan
Feng, Li [2 ]
Li, Hao [3 ]
Li, Yinan
机构
[1] Huazhong Univ Sci & Technol, Sch Elect Informat & Commun, Wuhan 430074, Peoples R China
[2] Hubei Univ Technol, Sch Elect & Elect Engn, Wuhan 430074, Peoples R China
[3] Xian Inst Space Radio Technol, Xian 710100, Peoples R China
基金
中国国家自然科学基金;
关键词
Amplitude and phase error; aperture synthesis radiometer (ASR); brightness temperature (BT); hybrid calibration; noise injection; redundant baselines; REDUNDANT SPACE CALIBRATION; INTERFEROMETRIC-RADIOMETER;
D O I
10.1109/LGRS.2016.2532966
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
The calibration of aperture synthesis radiometers (ASRs) with large arrays by internal noise injection suffers from high increased mass and volume and is not capable to deal with the out-of-plane distortion of antenna arrays. In this letter, a hybrid calibration method is proposed, which combines the redundant baselines and reduced noise injection. The hybrid method needs only a small noise injection network and can deal with the out-of-plane distortion of antenna arrays. The performance of the hybrid method depends on the noise injection element distribution, which is analyzed and given based on minimizing the root mean square of all residual amplitude and phase errors. Simulation results demonstrate its performance. The proposed hybrid method is particularly helpful to the calibration of ASRs with large arrays in geostationary orbit.
引用
收藏
页码:651 / 655
页数:5
相关论文
共 50 条
  • [41] Multi-Parameter Regularization Method for Synthetic Aperture Imaging Radiometers
    Yang, Xiaocheng
    Yang, Zhenyi
    Yan, Jingye
    Wu, Lin
    Jiang, Mingfeng
    [J]. REMOTE SENSING, 2021, 13 (03) : 1 - 15
  • [42] Initial Results of H-Matrix Reconstruction Method for 1-D Mirrored Aperture Synthesis Radiometers
    Li, Yufang
    Li, Qingxia
    Chen, Ke
    Gui, Liangqi
    Feng, Li
    Lei, Zhenyu
    [J]. IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, 2022, 19
  • [43] Reliability analysis in aperture synthesis interferometric radiometers:: Application to L band Microwave Imaging Radiometer with Aperture Synthesis instrument
    Vall-Ilossera, M
    Duffo, N
    Camps, A
    Corbella, I
    Torres, F
    Bará, J
    [J]. RADIO SCIENCE, 2001, 36 (01) : 107 - 117
  • [44] Calibration Method for Fully Polarimetric Microwave Radiometers Using the Correlated Noise Calibration Standard
    Peng, Jinzheng
    Ruf, Christopher S.
    [J]. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2008, 46 (10): : 3087 - 3097
  • [45] Calibration of shielded net radiometers
    Fritschen, Leo J.
    Fritschen, Charles L.
    [J]. AGRONOMY JOURNAL, 2007, 99 (01) : 297 - 303
  • [46] Inter-Calibration of Microwave Radiometers Using the Vicarious Cold Calibration Double Difference Method
    Kroodsma, Rachael A.
    McKague, Darren S.
    Ruf, Christopher S.
    [J]. IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2012, 5 (03) : 1006 - 1013
  • [47] ARRAY CONFIGURATION OPTIMIZATION FOR ONE-DIMENSIONAL NONUNIFORM APERTURE SYNTHESIS RADIOMETERS
    Feng, Li
    Li, Qingxia
    Wu, Minghu
    Li, Yufang
    Wang, Dongjian
    Gong, Pengcheng
    Li, Jie
    [J]. 2016 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2016, : 850 - 852
  • [48] The Placement of Antenna Elements in Aperture Synthesis Microwave Radiometers for Optimum Radiometric Sensitivity
    Dong, Jian
    Li, Qingxia
    Shi, Ronghua
    Gui, Liangqi
    Guo, Wei
    [J]. IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2011, 59 (11) : 4103 - 4114
  • [49] Means for Calibration of Radiometers.
    Le Calvez, Y.
    [J]. Onde electrique, 1988, 68 (05): : 39 - 41
  • [50] Uncertainty in calibration of ultraviolet radiometers
    Lloyd, JJ