Mapping of the prostate in endorectal coil-based MRI/MRSI and CT: A deformable registration and validation study

被引:60
|
作者
Lian, J
Xing, L
Hunjan, S
Dumoulin, C
Levin, J
Lo, A
Watkins, R
Rohling, K
Giaquinto, R
Kim, D
Spielman, D
Daniel, B
机构
[1] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
[2] GE Co, Ctr Corp Res & Dev, Schenectady, NY 12309 USA
[3] Stanford Univ, Sch Med, Dept Radiol, Stanford, CA 94305 USA
关键词
D O I
10.1118/1.1806292
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The endorectal coil is being increasingly used in magnetic resonance imaging (MRI) and MR spectroscopic imaging (MRSI) to obtain anatomic and metabolic images of the prostate with high signal-to-noise ratio (SNR). In practice, however, the use of endorectal probe inevitably distorts the prostate and other soft tissue organs, making the analysis and the use of the acquired image data in treatment planning difficult. The purpose of this work is to develop a deformable image registration algorithm to map the MRI/MRSI information obtained using an endorectal probe onto CT images and to verify the accuracy of the registration by phantom and patient studies. A mapping procedure involved using a thin plate spline (TPS) transformation was implemented to establish voxel-to-voxel correspondence between a reference image and a floating image with deformation. An elastic phantom with a number of implanted fiducial markers was designed for the validation of the quality of the registration. Radiographic images of the phantom were obtained before and after a series of intentionally introduced distortions. After mapping the distorted phantom to the original one, the displacements of the implanted markers were measured with respect to their ideal positions and the mean error was calculated. In patient studies, CT images of three prostate patients were acquired, followed by 3 Tesla (3 T) MR images with a rigid endorectal coil. Registration quality was estimated by the centroid position displacement and image coincidence index (CI). Phantom and patient studies show that TPS-based registration has achieved significantly higher accuracy than the previously reported method based on a rigid-body transformation and scaling. The technique should be useful to map the MR spectroscopic dataset acquired with ER probe onto the treatment planning CT dataset to guide radiotherapy planning. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:3087 / 3094
页数:8
相关论文
共 50 条
  • [41] Feasibility Study of B-Spline Deformable Registration between CT and MRI Atlas for Trigeminal Neuralgia Application to Radiosurgery
    Peroni, M.
    Stancanello, J.
    Muacevic, A.
    Riboldi, M.
    Spadea, M. F.
    Sharp, G. C.
    Baroni, G.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 1649 - 1652
  • [42] Region-Adaptive Deformable Registration of CT/MRI Pelvic Images via Learning-Based Image Synthesis
    Cao, Xiaohuan
    Yang, Jianhua
    Gao, Yaozong
    Wang, Qian
    Shen, Dinggang
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2018, 27 (07) : 3500 - 3512
  • [43] CREATION OF A RTOG COMPLIANT PROSTATE BED ATLAS ASSISTED BY A CT-BASED DEFORMABLE REGISTRATION CONTOURING SOFTWARE SYSTEM
    Rodrigues, G.
    Hwee, J.
    Louie, A.
    Piper, J.
    Bauman, G.
    Gaede, S.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S45 - S45
  • [44] Creation of a RTOG Compliant Prostate Bed Atlas Assisted by a CT-based Deformable Registration Contouring Software System
    Rodrigues, G.
    Hwee, J.
    Louie, A.
    Piper, J.
    Bauman, G.
    Gaede, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S360 - S360
  • [45] A radio-pathological correlation for prostate cancer detection - A study using DCE-MRI at 3T without an endorectal coil
    Dangle, Pankaj P.
    Samavedi, Srinivas
    Knopp, Michael
    Shah, Zarine
    Jia, Guang
    Takayama, Yukihisa
    Jimenez, Rafael
    Patel, Vipul R.
    JOURNAL OF UROLOGY, 2008, 179 (04): : 401 - 401
  • [46] An adversarial machine learning based approach and biomechanically-guided validation for improving deformable image registration accuracy between a planning CT and cone-beam CT for adaptive prostate radiotherapy applications
    Santhanam, Anand P.
    Lauria, Michael
    Stiehl, Brad
    Elliott, Daniel
    Seshan, Saty
    Hsieh, Scott
    Cao, Minsong
    Low, Daniel
    MEDICAL IMAGING 2020: IMAGE PROCESSING, 2021, 11313
  • [47] Histo-MRI map study protocol: a prospective cohort study mapping MRI to histology for biomarker validation and prediction of prostate cancer
    Singh, Saurabh
    Mathew, Manju
    Mertzanidou, Thomy
    Suman, Shipra
    Clemente, Joey
    Retter, Adam
    Papoutsaki, Marianthi-Vasiliki
    Smith, Lorna
    Grussu, Francesco
    Kasivisvanathan, Veeru
    Grey, Alistair
    Dinneen, Eoin
    Shaw, Greg
    Carter, Martyn
    Patel, Dominic
    Moore, Caroline M.
    Atkinson, David
    Panagiotaki, Eleftheria
    Haider, Aiman
    Freeman, Alex
    Alexander, Daniel
    Punwani, Shonit
    BMJ OPEN, 2022, 12 (04): : e059847
  • [48] Learning-Based MRI-CT Prostate Registration Using Spare Patch-Deformation Dictionary
    Yang, X.
    Jani, A.
    Rossi, P.
    Mao, H.
    Curran, W.
    Liu, T.
    MEDICAL PHYSICS, 2016, 43 (06) : 3884 - 3885
  • [49] Validation of a surface-based deformable MRI-3D ultrasound image registration algorithm toward clinical implementation for interstitial
    Orlando, Nathan
    Edirisinghe, Chandima
    Gyacskov, Igor
    Vickress, Jason
    Sachdeva, Robin
    Gomez, Jose A.
    D'Souza, David
    Velker, Vikram
    Mendez, Lucas C.
    Bauman, Glenn
    Fenster, Aaron
    Hoover, Douglas A.
    BRACHYTHERAPY, 2023, 22 (02) : 199 - 209
  • [50] Improved the Accuracy of Prostate Delineation for Ultrasound-Guided CT-Based Treatment Planning in Prostate HDR Brachytherapy: A Pilot Study with MRI Validation
    Yang, X.
    Rossi, P.
    Ogunleye, T.
    Curran, W.
    Liu, T.
    MEDICAL PHYSICS, 2013, 40 (06)