Autosynchronized systolic unloading during left ventricular assist with a centrifugal pump

被引:14
|
作者
Kono, S
Nishimura, K [1 ]
Nishina, T
Yuasa, S
Ueyama, K
Hamada, C
Akamatsu, T
Komeda, M
机构
[1] Kyoto Univ, Grad Sch Med, Dept Cardiovasc Surg, Sakyo Ku, Kyoto 6068507, Japan
[2] Kyoto Univ, Sch Publ Hlth, Dept Pharmacoepidemiol, Kyoto 6068507, Japan
[3] Setsunan Univ, Fac Engn, Dept Mech Engn, Kyoto, Japan
来源
关键词
D O I
10.1067/mtc.2003.100
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The purpose of this study was to investigate how the inflow cannulation site of the left ventricular assist system with a centrifugal pump would influence cardiac function on failing heart models. Methods: In 10 sheep, a left ventricular assist system was instituted by an outflow cannula in the descending aorta, two inflow cannulas in the left atrium and the left ventricle, and connecting those cannulas to a magnetically suspended centrifugal pump. A conductance catheter and a tipped micromanometer for monitoring the pressure-volume loop were also inserted into the left ventricle. Myocardial oxygen consumption was directly measured. Heart failure was induced by injection of microspheres into the left main coronary artery. The assist rate was varied from 0% to 100% at each inflow cannulation site. Results: The pump flow with left ventricular cannulation increased during the systolic phase and decreased during the diastolic phase, whereas it was constant with left atrial cannulation. Ejection fraction with left atrial cannulation decreased as the assist rate increased, whereas that with left ventricular carmulation was maintained up to 75% assist. The external work with left atrial cannulation decreased gradually as the assist rate increased, whereas the external work with left ventricular cannulation did not decrease until the assist rate reached 75%. The myocardial oxygen consumption in both cannulations decreased proportionally as the assist rate increased; they were significantly less with left ventricular cannulation at the 100% assist rate than with left atrial cannulation. Conclusion: Left ventricular cannulation during left ventricular assistance maintains ejection fraction and effectively reduces oxygen consumption.
引用
收藏
页码:353 / 360
页数:8
相关论文
共 50 条
  • [21] Long-term in vivo left ventricular assist device study with a titanium centrifugal pump
    Ohtsuka, Goro
    Nakata, Kin-Ichi
    Yoshikawa, Masaharu
    Mueller, Juergen
    Takano, Tamaki
    Yamane, Shingo
    Gronau, Nicole
    Glueck, Julia
    Takami, Yoshiyuki
    Sueoka, Akinori
    Letsou, George
    Schima, Heinrich
    Schmallegger, Helmut
    Wolner, Ernst
    Koyanagi, Hitoshi
    Fujisawa, Akira
    Baldwin, John C.
    Nosé, Yukihiko
    ASAIO Journal, 44 (05):
  • [22] Augmentation of intracoronary pressure and left ventricular systolic unloading during enhanced external counterpulsation
    Michaels, AD
    Accad, M
    Madden, J
    Dauterman, K
    Ports, TA
    Grossman, W
    CIRCULATION, 2002, 106 (19) : 319 - 320
  • [23] Left ventricular unloading with a microaxial flow-pump
    Sieweke, J. T.
    Berliner, D.
    Zauner, F.
    Flierl, U.
    Kruchten, S.
    Napp, L. C.
    Tongers, J.
    Bauersachs, J.
    Schaefer, A.
    EUROPEAN HEART JOURNAL, 2017, 38 : 604 - 605
  • [24] The pulsatile impeller pump for left ventricular assist
    Wang, SS
    Chu, SH
    Chou, NK
    Qian, KX
    ARTIFICIAL ORGANS, 1996, 20 (12) : 1310 - 1313
  • [25] A calf model for left ventricular centrifugal mechanical assist
    Mann, FA
    WagnerMann, CC
    Curtis, JJ
    Demmy, TL
    Turk, JR
    ARTIFICIAL ORGANS, 1996, 20 (06) : 670 - 677
  • [26] Left ventricular assist using a jet pump
    Rhee, K.
    Blackshear Jr., P.L.
    ASAIO Transactions, 1990, 36 (03):
  • [27] A tale of two centrifugal left ventricular assist devices
    Schroder, Jacob N.
    Milano, Carmelo A.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 154 (03): : 850 - 852
  • [28] Myocardial Recovery by Mechanical Unloading With Left Ventricular Assist System
    Matsumiya, Goro
    Saitoh, Shunsuke
    Sakata, Yasushi
    Sawa, Yoshiki
    CIRCULATION JOURNAL, 2009, 73 (08) : 1386 - 1392
  • [29] SUCCESSFUL POST-BYPASS VENTRICULAR ASSIST WITH A CENTRIFUGAL PUMP
    JAKOB, H
    MAASS, D
    BRANDT, L
    SCHUSTER, S
    MEYER, J
    OELERT, H
    THORACIC AND CARDIOVASCULAR SURGEON, 1987, 35 (02): : 91 - 95
  • [30] CLINICAL-EXPERIENCE WITH A CENTRIFUGAL PUMP VENTRICULAR ASSIST DEVICE
    PENNINGTON, DG
    MERJAVY, JP
    SWARTZ, MT
    WILLMAN, VL
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1982, 28 : 93 - 99