Autosynchronized systolic unloading during left ventricular assist with a centrifugal pump

被引:14
|
作者
Kono, S
Nishimura, K [1 ]
Nishina, T
Yuasa, S
Ueyama, K
Hamada, C
Akamatsu, T
Komeda, M
机构
[1] Kyoto Univ, Grad Sch Med, Dept Cardiovasc Surg, Sakyo Ku, Kyoto 6068507, Japan
[2] Kyoto Univ, Sch Publ Hlth, Dept Pharmacoepidemiol, Kyoto 6068507, Japan
[3] Setsunan Univ, Fac Engn, Dept Mech Engn, Kyoto, Japan
来源
关键词
D O I
10.1067/mtc.2003.100
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The purpose of this study was to investigate how the inflow cannulation site of the left ventricular assist system with a centrifugal pump would influence cardiac function on failing heart models. Methods: In 10 sheep, a left ventricular assist system was instituted by an outflow cannula in the descending aorta, two inflow cannulas in the left atrium and the left ventricle, and connecting those cannulas to a magnetically suspended centrifugal pump. A conductance catheter and a tipped micromanometer for monitoring the pressure-volume loop were also inserted into the left ventricle. Myocardial oxygen consumption was directly measured. Heart failure was induced by injection of microspheres into the left main coronary artery. The assist rate was varied from 0% to 100% at each inflow cannulation site. Results: The pump flow with left ventricular cannulation increased during the systolic phase and decreased during the diastolic phase, whereas it was constant with left atrial cannulation. Ejection fraction with left atrial cannulation decreased as the assist rate increased, whereas that with left ventricular carmulation was maintained up to 75% assist. The external work with left atrial cannulation decreased gradually as the assist rate increased, whereas the external work with left ventricular cannulation did not decrease until the assist rate reached 75%. The myocardial oxygen consumption in both cannulations decreased proportionally as the assist rate increased; they were significantly less with left ventricular cannulation at the 100% assist rate than with left atrial cannulation. Conclusion: Left ventricular cannulation during left ventricular assistance maintains ejection fraction and effectively reduces oxygen consumption.
引用
下载
收藏
页码:353 / 360
页数:8
相关论文
共 50 条
  • [1] Comparing the Effectiveness of an Axial and a Centrifugal Left Ventricular Assist Device in Ventricular Unloading
    Turer, David M.
    Koch, Kelly L.
    Koelling, Todd M.
    Wu, Audrey H.
    Pagani, Francis D.
    Haft, Jonathan W.
    ASAIO JOURNAL, 2016, 62 (06) : 652 - 656
  • [2] Evaluation of cardiac function during left ventricular assist by a centrifugal blood pump
    Kikugawa, D
    ARTIFICIAL ORGANS, 2000, 24 (08) : 632 - 635
  • [3] USE OF A CENTRIFUGAL PUMP FOR TEMPORARY LEFT-VENTRICULAR ASSIST SYSTEM
    GOLDING, LR
    HARASAKI, H
    LOOP, FD
    SUKALAC, R
    REICH, S
    NOSE, Y
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1978, 24 : 93 - 97
  • [4] USE OF A CENTRIFUGAL PUMP WITHOUT ANTICOAGULANTS FOR POSTOPERATIVE LEFT-VENTRICULAR ASSIST
    MAGOVERN, GJ
    PARK, SB
    MAHER, TD
    WORLD JOURNAL OF SURGERY, 1985, 9 (01) : 25 - 36
  • [5] Echocardiographic markers of left ventricular unloading using a centrifugal-flow rotary pump
    Sauer, Andrew J.
    Meehan, Karen
    Gordon, Robert
    Abicht, Travis
    Rich, Jonathan D.
    Anderson, Allen S.
    Yancy, Clyde
    McGee, Edwin C., Jr.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (04): : 449 - 450
  • [6] Cannula and Pump Positions Are Associated With Left Ventricular Unloading and Clinical Outcome in Patients With HeartWare Left Ventricular Assist Device
    Imamura, Teruhiko
    Adatya, Sirtaz
    Chung, Ben
    Nguyen, Ann
    Rodgers, Daniel
    Sayer, Gabriel
    Sarswat, Nitasha
    Kim, Gene
    Raikhelkar, Jayant
    Ota, Takeyoshi
    Song, Tae
    Juricek, Colleen
    Medvedofsky, Diego
    Jeevanandam, Valluvan
    Lang, Roberto
    Estep, Jerry D.
    Burkhoff, Daniel
    Uriel, Nir
    JOURNAL OF CARDIAC FAILURE, 2018, 24 (03) : 159 - 166
  • [7] Slope of the Anterior Mitral Valve Leaflet: A New Measurement of Left Ventricular Unloading for Left Ventricular Assist Devices and Systolic Dysfunction
    Martinez, Sara C.
    Bradley, Elisa A.
    Novak, Eric L.
    Rasalingam, Ravi
    Cedars, Ari M.
    Ewald, Gregory A.
    Silvestry, Scott C.
    Joseph, Susan M.
    TEXAS HEART INSTITUTE JOURNAL, 2014, 41 (03) : 262 - 272
  • [8] Changes of heart rate variability during left ventricular assist: comparison between pulsatile device and centrifugal pump
    Nishinaka, T., 1600, (Lippincott-Raven Publ, Baltimore, MD, United States):
  • [9] Inadequate left ventricular unloading during ramp is associated with hospitalization or death during left ventricular assist device support
    Rosenbaum, Andrew N.
    Stulak, John M.
    Clavell, Alfredo L.
    Behfar, Atta
    ARTIFICIAL ORGANS, 2021, 45 (02) : 115 - 123
  • [10] THE EFFECTS OF A CENTRIFUGAL PUMP AS A LEFT-VENTRICULAR-ASSIST DEVICE IN MYOCARDIAL-INFARCTION
    MATTILA, S
    HARJULA, A
    MATTILA, I
    HARKONEN, M
    MERIKALLIO, E
    TALA, P
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1982, 42 (08): : 637 - 642