Multi-scale X-ray tomography analysis of carbonate porosity

被引:32
|
作者
Hebert, V. [1 ]
Garing, C. [1 ]
Luquot, L. [1 ]
Pezard, P. A. [1 ]
Gouze, P. [1 ]
机构
[1] Univ Montpellier 2, CNRS, INSU, UMR 5243, F-34095 Montpellier, France
关键词
UPPER MIOCENE; TRANSPORT-PROPERTIES; REACTIVE FLUID; PORE STRUCTURE; CLASSIFICATION; PERMEABILITY; ROCKS; HETEROGENEITY; EVOLUTION; LIMESTONE;
D O I
10.1144/SP406.12
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
The porosity (from values of,1% up to more than 50%, with a mean value of 36.5%) and permeability (from very low values to 20.4 D, with a mean value around 800 mD) of 38 plugs, with a diameter 40 mm, have been measured. These plugs were taken approximately every 1.5 m along a 100 m-long core, sampling a series of reefal carbonate platform lithofacies. A non-unique relationship between porosity and permeability is obtained. In addition, the porosity was measured from processing X-ray micro-tomography images with resolutions ranging from 0.42 to 190.0 mm and sampling volumes ranging from less than 1 mm 3 to few cm 3. Depending on the structure of the pore network, the computed porosity is, in some cases, controlled by the X-ray image resolution and the sampled volume. While high resolution is required to image micro-porous material, large samples with lower resolution images are necessary for identifying distributed vugs and millimetre-scale structures. This study shows that multi-resolution X-ray micro-tomography is an effective tool for characterizing the multi-scale pore structure of carbonate rocks and understanding how it may control key petrophysical parameters such as porosity and permeability.
引用
收藏
页码:61 / 79
页数:19
相关论文
共 50 条
  • [31] Structural analysis of composites with porosity defects based on X-ray computed tomography
    Nikishkov, Yuri
    Seon, Guillaume
    Makeev, Andrew
    JOURNAL OF COMPOSITE MATERIALS, 2014, 48 (17) : 2131 - 2144
  • [32] Simple and fast porosity analysis of concrete using X-ray computed tomography
    du Plessis, Anton
    Olawuyi, Babatunde James
    Boshoff, William Peter
    le Roux, Stephan Gerhard
    MATERIALS AND STRUCTURES, 2016, 49 (1-2) : 553 - 562
  • [33] Simple and fast porosity analysis of concrete using X-ray computed tomography
    Anton du Plessis
    Babatunde James Olawuyi
    William Peter Boshoff
    Stephan Gerhard le Roux
    Materials and Structures, 2016, 49 : 553 - 562
  • [34] A multi-scale adaptive method for blood vessel enhancement in X-ray angiography
    Wu, ZY
    Fang, M
    Qian, JZ
    Schramm, H
    IMAGE PERCEPTION: MEDICAL IMAGING 1997, 1997, 3036 : 326 - 335
  • [35] Multi-scale image fusion for X-ray grating-based mammography
    Jiang, Xiaolei
    Zhang, Li
    Wang, Zhentian
    Stampanoni, Marco
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VIII, 2012, 8506
  • [36] Stress Sensitivity of Fractured and Vuggy Carbonate: An X-Ray Computed Tomography Analysis
    Yang, Yongfei
    Tao, Liu
    Yang, Haiyuan
    Iglauer, Stefan
    Wang, Xin
    Askari, Radwin
    Yao, Jun
    Zhang, Kai
    Zhang, Lei
    Sun, Hai
    JOURNAL OF GEOPHYSICAL RESEARCH-SOLID EARTH, 2020, 125 (03)
  • [37] Metal Crack Detection in X-ray Images Based on Local Brightness Variation and Multi-scale Analysis
    Peng, Shao-Hu
    Kim, Han-Seok
    Nam, Hyun-Do
    INFORMATION-AN INTERNATIONAL INTERDISCIPLINARY JOURNAL, 2012, 15 (05): : 1961 - 1972
  • [38] Fourier analysis of multi-scale neural networks implemented for high-resolution X-ray radiography
    Kim, Jinwoo
    Oh, Seokwon
    Kim, Ho Kyung
    NDT & E INTERNATIONAL, 2023, 139
  • [39] Use of X-ray tomography to study the porosity and morphology of granules
    Farber, L
    Tardos, G
    Michaels, JN
    POWDER TECHNOLOGY, 2003, 132 (01) : 57 - 63
  • [40] Analysis of Vesicular Porosity in Soils using High Resolution X-Ray Computed Tomography
    Turk, Judith K.
    Graham, Robert C.
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2014, 78 (03) : 868 - 880