Diagnostic value of 18F-FDG PET in the assessment of myocardial viability in coronary artery disease: A comparative study with 99mTc SPECT and echocardiography

被引:0
|
作者
Al Moudi, Mansour [1 ,2 ]
Sun, Zhong-Hua [2 ]
机构
[1] King Saud Med City, Dept Med Imaging & Nucl Med, Riyadh, Saudi Arabia
[2] Curtin Univ, Discipline Med Imaging, Dept Imaging & Appl Phys, Perth, WA 6845, Australia
关键词
Coronary artery disease; Diagnostic value; Positron emission tomography; Single photon emission computed tomography; Viability; POSITRON-EMISSION-TOMOGRAPHY; GUIDELINES ACC/AHA/ASNC COMMITTEE; ASSOCIATION TASK-FORCE; COMPUTED-TOMOGRAPHY; AMERICAN-COLLEGE; HEART-FAILURE; CLINICAL-USE; MANAGEMENT; REVASCULARIZATION; IMPROVEMENT;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To investigate the diagnostic value of 18F-fluorodeoxyglucose positron emission tomography (F-18-FDG PET) in the assessment of myocardial viability in patients with known coronary artery disease (CAD) when compared to Tc-99m single photon emission computed tomography (SPECT) and echocardiography, with invasive coronary angiography as the gold standard. Methods Thirty patients with diagnosed CAD met the selection criteria, with 10 of them (9 men, mean age 59.5 +/- 10.5 years) undergoing all of these imaging procedures consisting of SPECT and PET, echocardiography and invasive angiography. Diagnostic sensitivity of these less invasive modalities for detection of myocardial viability was compared to invasive coronary angiography. Inter-and intra-observer agreement was assessed for diagnostic performance of SPECT and PET. Results Of all patients with proven CAD, 50% had triple vessel disease. Diagnostic sensitivity of SPECT, PET and echocardiography was 90%, 100% and 80% at patient-based assessment, respectively. Excellent agreement was achieved between inter-observer and intra-observer agreement of the diagnostic value of SPECT and PET in myocardial viability (k = 0.9). Conclusion F-18-FDG PET has high diagnostic value in the assessment of myocardial viability in patients with known CAD when compared to SPECT and echocardiography. Further studies based on a large cohort with incorporation of F-18-FDG PET into patient management are warranted.
引用
收藏
页码:229 / 236
页数:8
相关论文
共 50 条
  • [31] A Small Field-Of-View, Mobile PET/SPECT System for Bedside Environments: A Dynamic Cardiac Phantom Study Using 99mTc and 18F-FDG
    Studenski, M.
    Gilland, D.
    Parker, J.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [32] Assessment of skeletal lesions using 99mTc MDP planar, SPECT, SPECT/CT, 18 F Fluoride PET & PET/CT
    Rangarajan, V.
    Purandare, N. C.
    Shah, S.
    Agrawal, A.
    Zade, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S153 - S153
  • [33] Low dose dobutamine stress gated 99mTc-tetrofosmin SPECT provides additional value for identification of myocardial viability -: Comparison with stress-rest perfusion SPECT and 18F-FDG PET.
    Yoshinaga, K
    Katoh, C
    Noriyasu, K
    Yamada, S
    Ito, Y
    Kuge, Y
    Kohya, T
    Kitabatake, A
    Tamaki, N
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 93P - 94P
  • [34] Interictal and ICTAL [99mTc]-HMPAO SPECT, [18F]FDG PET and MRI in temporal lobe epilepsy
    Asenbaum, S
    Diemling, M
    Hoffmann, M
    Becherer, A
    Baumgartner, C
    Olbrich, A
    Görzer, H
    Kletter, K
    Dudczak, R
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (01): : S92 - S92
  • [35] Prognostic value of myocardial viability assessment with 18FDG-PET in coronary artery disease patients with impaired left ventricular function
    Rendl, G.
    Keinrath, P.
    Rodrigues, M.
    Holzmannhofer, J.
    Altenberger, J.
    Pirich, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S344 - S345
  • [36] 11C-methionine uptake in cerebrovascular disease:: A comparison with 18F-FDG PET and 99mTc-HMPAO SPECT
    Nakagawa, M
    Kuwabara, Y
    Sasaki, M
    Koga, H
    Chen, T
    Kaneko, K
    Hayashi, K
    Morioka, T
    Masuda, K
    ANNALS OF NUCLEAR MEDICINE, 2002, 16 (03) : 207 - 211
  • [37] 18F-FDG PET in Myocardial Viability Assessment: A Practical and Time-Efficient Protocol
    Mhlanga, Joyce
    Derenoncourt, Paul
    Haq, Adeel
    Bhandiwad, Anita
    Laforest, Richard
    Siegel, Barry A.
    Dehdashti, Farrokh
    Gropler, Robert J.
    Schindler, Thomas H.
    JOURNAL OF NUCLEAR MEDICINE, 2022, 63 (04) : 602 - 608
  • [38] 18F-NaF PET-CT versus 99mTc SPECT in bone metastasis assessment
    Wang, Jiazheng
    Hesketh, Richard L.
    LANCET ONCOLOGY, 2023, 24 (02): : E68 - E68
  • [39] 99mTc Tetrofosmin gated SPECT with Nitrate in assessment of myocardial viability - study at patients who underwent Myocardial Revascularization
    Buzumurga, C.
    Suciu, C.
    Tudose, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S434 - S434
  • [40] The prognostic and diagnostic value of 18F-FDG PET/CT for assessment of symptomatic osteoarthritis
    Nguyen, Brian J.
    Burt, Ashley
    Baldassare, Randall L.
    Smitaman, Edward
    Morshedi, Maud
    Kao, Steven
    Chang, Eric Y.
    Obrzut, Sebastian
    NUCLEAR MEDICINE COMMUNICATIONS, 2018, 39 (07) : 699 - 706