A New PVC Matrix Membrane Sensor for Determination of Praseodymium(III) Ion Based on Bis(salicylaldehyde)thiocarbohydrazone as an Ion Carrier

被引:5
|
作者
Jahanian, Lida [1 ]
Zamani, Hassan Ali [1 ]
Joz-Yarmohammadi, Fatemeh [1 ]
Behmadi, Hossien [1 ]
Abedi, Mohammad Reza [2 ]
机构
[1] Islamic Azad Univ, Mashhad Branch, Dept Appl Chem, Mashhad, Iran
[2] Islamic Azad Univ, Quchan Branch, Dept Appl Chem, Quchan, Iran
关键词
sensor; PVC membrane; potentiometry; ion-selective electrode; RARE-EARTH-ELEMENTS; SELECTIVE ELECTRODE; TERBIUM(III) IONS; SENSING MATERIAL; FABRICATION; SAMPLES; CONSTRUCTION; NEODYMIUM; SAMARIUM; SOIL;
D O I
10.1134/S1023193517050068
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The sufficient amounts of bis(salicylaldehyde) thiocarbohydrazone (STCH) as a lipophilic selective element (3%, w/w), sodium nitrobenzene (NB) as a plasticizer (64%, w/w), tetraphenyl borate (NaTPB) as an anionic additive (3%, w/w), and poly vinyl chloride (PVC) as a polymeric matrix (30%, w/w) was employed to form a PVC membrane of a new Pr3+ ions selective sensor to apply as an indicator electrode in analytical applications. The best electrode response was observed in the slope (19.5 +/- 0.7 mV per decade) over a wide concentrations from lower (1.0 x 10(-6) mol L-1) to higher (1.0 x 10(-2) mol L-1) of Pr3+ ion solution with a detection limit of 8.5 x 10(-7) mol L-1. This electrode showed the fast response time about 10 second for praseodymium ion concentration range of 1.0 x 10(-6) to 1.0 x 10(-2) mol L-1, in the pH range of 2.3-7.9. The matched potential method was applied to study the selectivity of electrode toward Pr3+ ions in comparison with many common cations. The results showed the negligible disturbance of all other cations on the proposed praseodymium(III) electrode. The making sensor has been employed successfully as an indicator electrode in the potentiometric titration of praseodymium(III) solution with EDTA at pH 6.0. Moreover the applicability of the sensor was studied in determination of Pr3+ ion in mixtures of different ions.
引用
收藏
页码:435 / 442
页数:8
相关论文
共 50 条
  • [31] An optical chemical sensor for mercury ion based on 2-mercaptopyrimidine in PVC membrane
    Khezri, Bahareh
    Amini, Mohammad K.
    Firooz, Ali R.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (07) : 1943 - 1950
  • [32] An optical chemical sensor for mercury ion based on 2-mercaptopyrimidine in PVC membrane
    Bahareh Khezri
    Mohammad K. Amini
    Ali R. Firooz
    Analytical and Bioanalytical Chemistry, 2008, 390 : 1943 - 1950
  • [33] An optical sensor for mercuric ion based on immobilization of Rhodamine B derivative in PVC membrane
    Ling, Lixin
    Zhao, Yan
    Du, Juan
    Xiao, Dan
    TALANTA, 2012, 91 : 65 - 71
  • [34] An iron(III) ion-selective sensor based on a μ-bis(tridentate) ligand
    Gupta, Vinod K.
    Jain, A. K.
    Agarwal, Shiva
    Maheshwari, Gaurav
    TALANTA, 2007, 71 (05) : 1964 - 1968
  • [35] Neutral carrier based needle-type sensor for the determination of calcium ion
    Li, XL
    Hong, DQ
    Li, YY
    Lin, ZH
    Ren, S
    INTERNATIONAL CONFERENCE ON SENSOR TECHNOLOGY (ISTC 2001), PROCEEDINGS, 2001, 4414 : 115 - 117
  • [36] Silver(I) ion selective PVC membrane based on bis-pyridine tetramide macrocycle
    Mahajan, RK
    Parkash, O
    TALANTA, 2000, 52 (04) : 691 - 693
  • [37] Determination of Dysprosium(III) Ion in Soil and Sediment Samples by an Original Potentiometric Dysprosium(III) Membrane Sensor
    Zamani, Hassan Ali
    Mohaddeszadeh, Mahbobeh
    ANALYTICAL LETTERS, 2008, 41 (14) : 2710 - 2726
  • [38] A New PVC-Membrane Based Ion-Selective Electrode for Perchlorate
    Yari, Abdollah
    Shamsipur, Mojtaba
    De Filippo, Greta
    Lippolis, Vito
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2009, 1 (02): : 60 - 70
  • [39] Potentiometric determination of cadmium using coated platinum and PVC membrane sensors based on N,N'-bis(salicylaldehyde)phenylenediamine (salophen)
    Mirzaei, Mohammad
    Pili, Hadi Behrooj
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (06) : 731 - 737