Surface analysis by secondary-ion mass spectroscopy during etching with gas-cluster ion beam

被引:1
|
作者
Fenner, DB [1 ]
Shao, Y [1 ]
机构
[1] JDS Uniphase Corp, Epion Corp, Billerica, MA 01821 USA
来源
关键词
D O I
10.1116/1.1524144
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Primary ions from a gas-cluster ion beam (GCIB) are used to investigate metal and silicon surfaces by mass spectroscopy of the secondary ions, as well as to study the nature of cluster-ion interactions with surfaces. The GCIB consists of condensed nanodroplets of either argon, oxygen, or nitrogen gas from which the singly charged cluster ions are generated. The effects of beam acceleration (similar to10-25 kV) and flux (ion current density similar to50-500 nA/cm(2)) are reported. Secondary-ion analysis is done with a quadrupole mass spectrometer in an ultrahigh vacuum chamber. Argon GCIB incident upon metal surfaces of Al, Au, Cu, Ta, and NiFe all result in strong emission of small metal-cluster ions, metal-argon excimers and various other compound ions. Argon GCIB incident upon Al films and Si wafer surfaces generate strong fluxes of small cluster ions (i.e., Al-n(+) and Si-n(+) for n = 2-10) which decay in emission intensity (with increasing n) approximately by a power law with exponent similar to2.8 and similar to1.0, respectively. Oxygen GCIB upon Al and Si generate strong fluxes of AlnOm+ and SinOm+ compound ions, respectively, with n = 1-5 and m greater than or equal to n. Nitrogen GCIB upon Al and Si generate fluxes of nitride compounds. The beam conditions utilized are similar to those known to significantly reduce fine-scale surface roughness (i.e., ion smoothen) and concurrently etch at a rate of similar to1 nm/min. Native oxide films on Al, Cu, Ta, and NiFe metals are depth profiled under various GCIB conditions, thus characterizing mechanisms of cluster-ion interaction with metals. The native surface of a Ta film is investigated in some detail. The TaO+ and C+ ion emissions show a two-part decay and growth, respectively, with accumulating argon-GCIB fluence. These are well fit with exponential functions and the characteristic rates are found to depend linearly on GCIB flux and acceleration. The oxidized surfaces exhibit a minimum threshold in acceleration of similar to7 kV which corresponds to only similar to3 eV per incident argon atom. After the surface oxide is removed by the GCIB, no threshold is observed. The native oxides and Fe/Ni, ratio are depth profiled for a permalloy (NiFe) film showing resolution of the thin oxide layer differentiated from the somewhat thicker metal layer that is enriched with Fe. (C) 2003 American Vacuum Society.
引用
收藏
页码:47 / 58
页数:12
相关论文
共 50 条
  • [41] ANALYSIS OF ADDITIVES ON BEO-DOPED SIC CERAMICS BY SECONDARY-ION MASS-SPECTROSCOPY
    TANAKA, S
    SAKAGUCHI, I
    YASUTOMI, Y
    MIYATA, M
    SAWAI, Y
    TAKAHASHI, K
    JOURNAL OF THE CERAMIC SOCIETY OF JAPAN, 1995, 103 (08) : 870 - 872
  • [42] Direct Analysis of Ion-Induced Peptide Fragmentation in Secondary-Ion Mass Spectrometry
    Schneider, P.
    Verloh, F.
    Portz, A.
    Aoyagi, S.
    Rohnke, M.
    Duerr, M.
    ANALYTICAL CHEMISTRY, 2020, 92 (23) : 15604 - 15610
  • [43] Polishing superhard material surfaces with gas-cluster ion beams
    Ieshkin, A. E.
    Kushkina, K. D.
    Kireev, D. S.
    Ermakov, Yu. A.
    Chernysh, V. S.
    TECHNICAL PHYSICS LETTERS, 2017, 43 (01) : 95 - 97
  • [44] SECONDARY-ION MASS-SPECTROMETRY AND GEOLOGY
    MACRAE, ND
    CANADIAN MINERALOGIST, 1995, 33 : 219 - 236
  • [45] CHARACTERIZATION OF REACTIVE ION-BEAM AND ION BEAM-ASSISTED ETCHING USING DIRECT ION MASS ANALYSIS AND EMISSION-SPECTROSCOPY
    CHINN, JD
    ADESIDA, I
    WOLF, ED
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1984, 131 (08) : C309 - C309
  • [46] Secondary-ion mass spectroscopy (SIMS) investigations of Be and Si incorporation in GaN grown by molecular beam epitaxy (MBE)
    Cheng, TS
    Foxon, CT
    Jenkins, LC
    Hooper, SE
    Lacklison, DE
    Orton, JW
    Ber, BY
    Merkulov, AV
    Novikov, SV
    SEMICONDUCTOR SCIENCE AND TECHNOLOGY, 1996, 11 (04) : 538 - 541
  • [47] Secondary-ion mass spectrometry of photoconducting targets
    Serdobintsev, A. A.
    Rokakh, A. G.
    Stetsyura, S. V.
    Zhukov, A. G.
    TECHNICAL PHYSICS, 2007, 52 (11) : 1483 - 1489
  • [48] SECONDARY-ION MASS-SPECTROMETRY IMAGING
    ODOM, RW
    APPLIED SPECTROSCOPY REVIEWS, 1994, 29 (01) : 67 - 116
  • [49] SECONDARY-ION MASS-SPECTROMETRY - FOREWORD
    BENTZ, BL
    ODOM, RW
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1995, 143 : R9 - R9
  • [50] Secondary-ion mass spectrometry of photoconducting targets
    A. A. Serdobintsev
    A. G. Rokakh
    S. V. Stetsyura
    A. G. Zhukov
    Technical Physics, 2007, 52 : 1483 - 1489