High frequency ultrasound measurement of digital dermal thickness in systemic sclerosis

被引:85
|
作者
Kaloudi, Olga [1 ]
Bandinelli, Francesca [1 ]
Filippucci, Emilio [2 ]
Conforti, Maria Letizia [1 ]
Miniati, Irene [1 ]
Guiducci, Serena [1 ]
Porta, Francesco [1 ]
Candelieri, Antonio [3 ]
Conforti, Domenico [3 ]
Grassiri, Genesio [4 ]
Grassi, Walter [2 ]
Matucci-Cerinic, Marco [1 ]
机构
[1] Univ Florence, Ctr Denothe, Div Rheumatol AOUC, Dept Biomed, I-50139 Florence, Italy
[2] Univ Marche, Div Rheumatol, Ancona, Italy
[3] Univ Calabria, Dept Elect Informat & Syst, Lab Decis Engn Hlth Care Delivery, I-87036 Cosenza, Italy
[4] Esaote, Genoa, Italy
关键词
RODNAN SKIN SCORE; INVOLVEMENT; SCLERODERMA;
D O I
10.1136/ard.2009.114843
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Currently, assessment of dermal thickness in systemic sclerosis (SSc) is performed by palpation and assessment using the modified Rodnan skin score (mRSS). Objective To verify whether high frequency ultrasound (US) may be a reliable and a reproducible method to measure digital dermal thickness. Methods In 70 patients with SSc, skin thickness was evaluated with US by 2 observers at 2 different sites on the second digit of the dominant limb to determine the interobserver variability. Patients and controls were examined twice by the first observer for intraobserver variability. Patients were divided into three subgroups according to the phase of the disease (oedematous, fibrotic or atrophic). Results At both examined areas, US showed a significant dermal thickening (p < 0.001) in the whole group of patients with SSc. A low intraobserver and interobserver variability was found. A highly significant correlation between the global mRSS and the local dermal thickness at the two examined sites (p = 0.032, p = 0.021) was detected. Skin thickness was significantly higher in the oedematous than in the fibrotic group (p < 0.001) and significantly higher in the fibrotic and the oedematous group (p < 0.001) than in the atrophic group (p < 0.002). Conclusions US is a reliable tool giving reproducible results, and is able to detect digital dermal thickening in SSc.
引用
收藏
页码:1140 / 1143
页数:4
相关论文
共 50 条
  • [21] Photoacoustic and high-frequency ultrasound imaging of systemic sclerosis patients
    Daoudi, Khalid
    Kersten, Brigit E.
    van den Ende, Cornelia H. M.
    van den Hoogen, Frank H. J.
    Vonk, Madelon C.
    de Korte, Chris L.
    ARTHRITIS RESEARCH & THERAPY, 2021, 23 (01)
  • [22] DIAGNOSING SYSTEMIC SCLEROSIS WITH PHOTOACOUSTIC AND HIGH-FREQUENCY ULTRASOUND IMAGING
    Kersten, B.
    Daoudi, K.
    Van den Ende, C. H. M.
    Van den Hoogen, F.
    De Korte, C.
    Vonk, M.
    ANNALS OF THE RHEUMATIC DISEASES, 2020, 79 : 1584 - 1584
  • [23] High-frequency photoacoustic and ultrasound imaging of systemic sclerosis patients
    Daoudi, Khalid
    Kersten, Brigit E.
    Vonk, Madelon
    de Korte, Chris L.
    OPTO-ACOUSTIC METHODS AND APPLICATIONS IN BIOPHOTONICS IV, 2019, 11077
  • [24] Photoacoustic and high-frequency ultrasound imaging of systemic sclerosis patients
    Khalid Daoudi
    Brigit E. Kersten
    Cornelia H. M. van den Ende
    Frank H. J. van den Hoogen
    Madelon C. Vonk
    Chris L. de Korte
    Arthritis Research & Therapy, 23
  • [25] Comparison of Optical Coherence Tomography and High Frequency Ultrasound As Measures of Skin Thickness in Systemic Sclerosis; A Pilot Study.
    Murray, Andrea
    Buckley, Donna
    Dinsdale, Graham
    Moore, Tonia
    Dickinson, Mark
    Herrick, Ariane
    ARTHRITIS AND RHEUMATISM, 2011, 63 (10): : S72 - S73
  • [26] Seventeen-point dermal ultrasound scoring system - a reliable measure of skin thickness in patients with systemic sclerosis
    Moore, TL
    Lunt, M
    McManus, B
    Anderson, ME
    Herrick, AL
    RHEUMATOLOGY, 2003, 42 (12) : 1559 - 1563
  • [27] Measurement of amniochorionic membrane thickness using high-frequency ultrasound
    Frigo, P
    Lang, C
    Golaszewski, T
    Gruber, D
    Berger, A
    Ulrich, R
    Eppel, W
    Huber, J
    PRENATAL DIAGNOSIS, 1996, 16 (04) : 313 - 317
  • [28] Measurement of amniochorionic membrane thickness using high-frequency ultrasound
    Frigo, P
    Lang, C
    Golaszewski, T
    Sator, M
    Ullrich, R
    Eppel, W
    Schurz, B
    ULTRASCHALL IN DER MEDIZIN, 1996, 17 (04): : 167 - 170
  • [29] Choroidal thickness measurement using tissue identification with high frequency ultrasound
    Chan, R
    Coleman, D
    Rondeau, MJ
    Silverman, RH
    Lloyd, HO
    Lizzi, FL
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U51 - U51
  • [30] EVALUATION OF DERMAL THICKNESS BY THREE DIFFERENT TECHNIQUES IN SYSTEMIC SCLEROSIS PATIENTS
    Ruaro, B.
    Sulli, A.
    Paolino, S.
    Pizzorni, C.
    Cutolo, M.
    ANNALS OF THE RHEUMATIC DISEASES, 2016, 75 : 1106 - 1106