Noninvasive continuous optoacoustic monitor of total hemlobin concentration

被引:2
|
作者
Brecht, HP [1 ]
Petrov, YY [1 ]
Prough, DS [1 ]
Deyo, DJ [1 ]
Hartrumpf, O [1 ]
Esenaliev, RO [1 ]
机构
[1] Univ Texas, Med Branch, Lab Opt Sensing & Monitoring, Galveston, TX 77550 USA
关键词
noninvasive monitoring; tissue; hemoglobin; optics;
D O I
10.1109/IEMBS.2002.1053286
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
During surgery associated with rapid blood loss, rapid fluid administration and transfusion of packed red blood cells, measurement of total hemoglobin concentration provides necessary information to direct decisions regarding transfusion. However, measurement of total hemoglobin concentration currently requires collection of a blood sample and either transport to a laboratory or centrifugation at the bedside. Recently we proposed to use optoacoustic technique for noninvasive and continuous monitoring of total hemoglobin concentration. High resolution of the optoacoustic technique may provide accurate measurement of total hemoglobin concentration by detecting and analyzing optoacoustic signals induced by short optical pulses in blood circulating in arteries or veins. We designed, built, and tested in vitro and in preliminary in vivo experiments a portable optoacoustic system for monitoring of total hemoglobin concentration in the radial artery. The system includes a nanosecond laser operating in the. near-IR spectral range and a sensitive optoacoustic probe designed for irradiating the radial artery through the skin and detecting optoacoustic signals induced in blood. Results of our studies indicate that parameters of optoacoustic waves induced in blood are,dependent on total hemoglobin concentration. The data suggest that the optoacoustic system may be used for accurate, noninvasive, and continuous monitoring of total hemoglobin concentration.
引用
收藏
页码:2289 / 2290
页数:2
相关论文
共 50 条
  • [41] Optoacoustic technique for noninvasive monitoring of blood oxygenation: a feasibility study
    Esenaliev, RO
    Larina, IV
    Larin, KV
    Deyo, DJ
    Motamedi, M
    Prough, DS
    APPLIED OPTICS, 2002, 41 (22) : 4722 - 4731
  • [42] A flexible optoacoustic blood ‘stethoscope’ for noninvasive multiparametric cardiovascular monitoring
    Haoran Jin
    Zesheng Zheng
    Zequn Cui
    Ying Jiang
    Geng Chen
    Wenlong Li
    Zhimin Wang
    Jilei Wang
    Chuanshi Yang
    Weitao Song
    Xiaodong Chen
    Yuanjin Zheng
    Nature Communications, 14
  • [43] Noninvasive, optoacoustic monitoring of cerebral venous blood oxygenation in newborns
    Petrov, Irene Y.
    Wynne, Karon E.
    Petrov, Yuriy
    Esenaliev, Rinat O.
    Richardson, C. Joan
    Prough, Donald S.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2012, 2012, 8223
  • [44] Could optoacoustic spectrometry make noninvasive glucose monitoring viable?
    Gefvert, Barbara
    LASER FOCUS WORLD, 2018, 54 (05): : 21 - 23
  • [45] Optoacoustic technique for noninvasive monitoring of endotracheal tube placement and positioning
    Prough, Donald S.
    Petrov, Yuriy
    Petrov, Irene
    Kinsky, Michael
    Esenaliev, Rinat O.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2011, 2011, 7899
  • [46] In vivo noninvasive monitoring of cerebral blood oxygenation with optoacoustic technique
    Petrov, YY
    Prough, DS
    Deyo, DJ
    Petrova, IY
    Motamedi, A
    Esenaliev, RO
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 2052 - 2054
  • [47] Effects of indigo carmine intravenous injection on noninvasive and continuous total hemoglobin measurement
    Isosu, Tsuyoshi
    Satoh, Tomohiko
    Oishi, Rieko
    Imaizumi, Tsuyoshi
    Hakozaki, Takahiro
    Obara, Shinju
    Ikegami, Yukihiro
    Kurosawa, Shin
    Murakawa, Masahiro
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2016, 30 (03) : 313 - 316
  • [48] Effects of indigo carmine intravenous injection on noninvasive and continuous total hemoglobin measurement
    Tsuyoshi Isosu
    Tomohiko Satoh
    Rieko Oishi
    Tsuyoshi Imaizumi
    Takahiro Hakozaki
    Shinju Obara
    Yukihiro Ikegami
    Shin Kurosawa
    Masahiro Murakawa
    Journal of Clinical Monitoring and Computing, 2016, 30 : 313 - 316
  • [49] Noninvasive optoacoustic system for rapid diagnostics and management of circulatory shock
    Esenaliev, Rinat O.
    Petrov, Irene Y.
    Petrov, Yuriy
    Kinsky, Michael
    Prough, Donald S.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2012, 2012, 8223
  • [50] A flexible optoacoustic blood 'stethoscope' for noninvasive multiparametric cardiovascular monitoring
    Jin, Haoran
    Zheng, Zesheng
    Cui, Zequn
    Jiang, Ying
    Chen, Geng
    Li, Wenlong
    Wang, Zhimin
    Wang, Jilei
    Yang, Chuanshi
    Song, Weitao
    Chen, Xiaodong
    Zheng, Yuanjin
    NATURE COMMUNICATIONS, 2023, 14 (01)