Spiral and oblique fractures of distal one-third of tibia-fibula: Treatment results with circular external fixator

被引:0
|
作者
Demiralp, Bahtiyar
Atesalp, Ali Sabri
Bozkurt, Murat
Bek, Dogan
Tasatan, Ersin
Ozturk, Cagatay
Basbozkurt, Mustafa
机构
[1] Gulhane Mil Med Acad, Fac Med, Dept Orthopaed & Traumatol, Ankara, Turkey
[2] Diskapl Res & Educ Hosp, Dept Orthopaed & Traumatol, Ankara, Turkey
[3] Turkish Armed Forces Rehabil & Care Ctr, Dept Orthopaed & Traumatol, Ankara, Turkey
关键词
distal tibia; external fixation; ilizarov; oblique fractures;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Spiral and oblique fractures of distal 1/3 of tibia-fibula are relatively common fractures of long bones. Due to their types, aetiology, limited coverage and blood supply, these fractures often lead to union and soft tissue problems. Materials and Methods: Twenty-seven patients with spiral and oblique fractures of distal 1/3 of tibia-fibula were treated with circular external fixator (CEF) between January 1997 and August 2000. All the fractures were closed. The type of fractures based on AO classification were A1 (n = 8), A2 (n = 6), B1 (n = 11) and C1 (n=2). Results: The mean framing time was 14.1 +/- 1.8 weeks (range, 12 to 19 weeks), and the mean treatment time was 18.8 +/- 2.2 weeks (range, 15 to 24 weeks). The patients were followed up for 36 to 78 months (mean follow-up time: 51.9 +/- 10.4 months). The results were evaluated for shortness, angulation, rotation, ankle stiffness, pain and infection. After removal of the frames, 11 patients had ankle pain and stiffness, and 3 patients had loss of range of motion in the ankle even after rehabilitation. None of the patients suffered any complications such as shortness, angulation, rotational deformity and infection, and none had loss of motion in the knee. Conclusions: CEF might be a preferable alternative treatment for distal tibia-fibula fractures due to its easy application, fewer major complications such as shortness and angulation, early mobilisation and shorter treatment time.
引用
收藏
页码:267 / 271
页数:5
相关论文
共 30 条
  • [21] Unilateral External Fixator Combined with Lateral Auxiliary Frame for Ultimate Treatment of Tibia and Fibula Shaft Fractures with Poor Soft Tissue Conditions
    Wang, Xinhui
    Wang, Bao
    Hou, Xizhi
    Cheng, Xiaodong
    Zhang, Tao
    BIOMED RESEARCH INTERNATIONAL, 2022, 2022
  • [22] The Treatment Method and Results of Percutaneous Pinning and Dynamic External Fixator Application for Unstable Distal Radius Fractures
    Kara, Adnan
    Erturer, Erden
    Seckin, Faik
    Akman, Senol
    Ozturk, Irfan
    MEDICAL BULLETIN OF SISLI ETFAL HOSPITAL, 2018, 52 (03): : 173 - 178
  • [23] Early results of functional treatment of distal radius fractures with the aid of Dynastab N (wrist) external fixator
    Nowak, P. G.
    Deszczynski, J.
    Karpinski, J.
    Surowiecki, R.
    PROCEEDINGS OF THE 7TH EUROPEAN TRAUMA CONGRESS, 2006, : 305 - +
  • [24] Intramedullary Nailing of Proximal and Distal One-Third Tibial Shaft Fractures With Intraoperative Two-Pin External Fixation
    Wysocki, Robert W.
    Kapotas, James S.
    Virkus, Walter W.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2009, 66 (04): : 1135 - 1139
  • [25] The treatment of unstable fractures of the distal radius using a bridging external fixator. Results from a longterm evaluation
    Joosten, U
    Joist, A
    Frebel, T
    Rieger, H
    CHIRURG, 1999, 70 (11): : 1315 - 1322
  • [26] Minimally invasive elastic intramedullary nails and external fixation achieved satisfactory outcomes for multi-segment and long-spiral mild-to-moderate comminuted closed tibia-fibula fractures
    Yu, Yang
    Chen, Ying
    Tao, Zhoushan
    Liao, Wei
    Zhou, Yifei
    Yang, Lei
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (07): : 10587 - 10596
  • [27] Results of Distal Tibia Extra-Articular Type I & Type II Open Fractures Treated with Primary Ilizarov External Fixator - A Prospective Observational Study
    Barua, Debanga Sarma
    Bora, Monoranjan How
    Das, Manas Jyoti
    Bansal, Sidhartha
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2019, 8 (37): : 2856 - 2860
  • [28] Treatment of Schatzker Type VI Tibia Fractures Using Circular External Fixation: State of the Art, Surgical Technique and Results
    Ros, Javier Martinez
    Martinez, Alonso Escudero
    Ros, Miguel Martinez
    Gonzalez, Jose Molina
    Garcia, Maria Carrillo
    Panos, Juan Pedro Garcia
    Garcia-Sandoval, Jose Pablo Puertas
    Canovas, Cesar Salcedo
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (05)
  • [29] One-third tubular-hook-plate osteosynthesis for olecranon osteotomies in distal humerus type-C fractures: A preliminary report of results and complications
    Schmidt-Horlohe, K.
    Wilde, P.
    Bonk, A.
    Becker, L.
    Hoffmann, R.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (03): : 295 - 300
  • [30] Long-term results of treatment of Gustilo-Anderson type 3A-B tibia fractures due to combat-related high-energy ballistic injuries treated with external circular fixator: Experience of the Military Medical Academy
    Erdem, Yusuf
    Zeybek, Hakan
    Neyisci, Cagri
    Bahtiyar, Eyyup Emre
    Uysal, Ozgur Selim
    Kurklu, Mustafa
    JOINT DISEASES AND RELATED SURGERY, 2024, 35 (03): : 637 - 644