Value of contrast-enhanced power Doppler sonography using a microbubble

被引:24
|
作者
Kook, SH [1 ]
Kwag, HJ [1 ]
机构
[1] Sungkyunkwan Univ, Kangbuk Samsung Hosp, Dept Radiol, Sch Med,Jongro Gu, Seoul 110108, South Korea
关键词
breast neoplasms; diagnosis; ultrasonography; contrast media; power Doppler ultrasonography;
D O I
10.1002/jcu.10172
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Purpose. The purpose of this study was to prospectively evaluate the usefulness of contrast-enhanced power Doppler sonography (PDUS) using a microbubble echo-enhancing agent in differentiating between malignant and benign small breast lesions. Patients and Methods. Between July 1, 2000, and September 30, 2001, we performed gray-scale sonographic examination of patients in whom diagnostic sonography or screening mammography had revealed solid breast lesions measuring less than 2 cm in the largest dimension. The patients were then examined on PDUS before and after injection of a microbubble contrast agent. The sonographic findings for all 3 techniques, as well as the morphologic features of the Doppler signals for each patient before and after injection of the contrast agent on PDUS, were independently assessed. Each lesion was classified as "benign" or "malignant" on the basis of specific criteria for sonographic interpretation. A hemodynamic study was performed in which time-transit profiles of the Doppler signals on contrast-enhanced PDUS were generated using a computer-assisted program, and the results for each patient were compared with the findings of a histopathologic examination of surgical specimens. Results. Thirty-six patients (35 women and 1 man) with a mean age of 43.5 years (range, 18-69 years) were evaluated. The tumors ranged from 4 to 19 mm in the largest dimension, Histopathologic examination revealed that 19 tumors were benign and 17 were malignant. For morphologic diagnosis of the malignant lesions, the sensitivity of gray-scale sonography was 100%, compared with 29% for PDUS without contrast enhancement. The specificity of gray-scale sonography was 47%, compared with 74% for PDUS without contrast enhancement. Contrast-enhanced PDUS had a sensitivity of 71% and a specificity of 58%. The diagnostic accuracy was 72% for gray-scale sonography, 53% for PDUS without contrast enhancement, and 64% for contrast-enhanced PDUS. The time-transit profiles of the hemodynamic study did not reveal a statistically significant difference in the accuracy rates of contrast-enhanced PDUS between benign and malignant breast lesions. Conclusions. Compared with PDUS without contrast enhancement, contrast-enhanced PDUS provides better visualization of the morphology of vascular Doppler signals; that is characteristic of malignancy and therefore has a higher sensitivity and diagnostic accuracy, albeit a lower specificity. In differentiating between benign and malignant small breast lesions,contrast-enhanced PDUS can be helpful when used with gray-scale sonography and PDUS without contrast enhancement. (C) 2003 Wiley Periodicals, Inc.
引用
收藏
页码:227 / 238
页数:12
相关论文
共 50 条
  • [21] Value of contrast-enhanced sonography in the diagnosis of vesicoureteral reflux
    Conen, Patrick
    Thiemann, Janine
    Stredele, Regina
    Clevert, Dirk Andre
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2024, 196 (10): : 1022 - 1028
  • [22] Evaluation of dynamic contrast-enhanced power Doppler sonography in the differential diagnosis of liver tumors using two different contrast agents
    Strobel, D
    Hoefer, A
    Martus, P
    Hahn, EG
    Becker, D
    RADIOLOGY, 1999, 213P : 489 - 489
  • [23] Value of contrast-enhanced color Doppler sonography as an adjunct before biopsy for detection of prostatic carcinoma
    Roy, C
    Tuchmann, CT
    Vasilescu, C
    Guth, S
    Lang, H
    Saussine, C
    RADIOLOGY, 2000, 217 : 364 - 364
  • [24] Diagnostic value of contrast-enhanced intraoperative Doppler sonography for cerebral arteriovenous malformations compared with angiography
    Xu Hong-zhi
    Qin Zhi-yong
    Gu Yu-xiang
    Zhou Ping
    Chen Xian-cheng
    CHINESE MEDICAL JOURNAL, 2010, 123 (20) : 2812 - 2815
  • [25] Diagnostic value of contrast-enhanced intraoperative Doppler sonography for cerebral arteriovenous malformations compared with angiography
    XU HongzhiQIN ZhiyongGU YuxiangZHOU Ping and CHEN Xiancheng Department of NeurosurgeryHuashan HospitalFudan University
    Shanghai Neurosurgical CenterShanghai China
    中华医学杂志(英文版), 2010, (20) : 2812 - 2815
  • [26] Correlation between estimates of tumor perfusion from microbubble contrast-enhanced sonography and dynamic contrast-enhanced magnetic resonance imaging
    Yankeelov, TE
    Niermann, KJ
    Huamani, J
    Kim, DW
    Quarles, CC
    Fleischer, AC
    Hallahan, DE
    Price, RR
    Gore, JC
    JOURNAL OF ULTRASOUND IN MEDICINE, 2006, 25 (04) : 487 - 497
  • [27] Evaluation of Focal Fatty Infiltration of the Liver Using Color Doppler and Contrast-Enhanced Sonography
    Liu, Li-Ping
    Dong, Bao-Wei
    Yu, Xiao-Ling
    Zhang, Da-Kun
    Kang, Chun-Song
    Zhao, Xi-Hai
    JOURNAL OF CLINICAL ULTRASOUND, 2008, 36 (09) : 560 - 566
  • [28] Evaluation of dynamic contrast-enhanced power Doppler sonography in the differential diagnosis of liver tumors.
    Strobel, DD
    Hoefer, A
    Martus, P
    Hahn, EG
    Becker, D
    GASTROENTEROLOGY, 2000, 118 (04) : A269 - A269
  • [29] An algorithm for the diagnosis of focal liver masses using microbubble contrast-enhanced pulse-inversion sonography
    Wilson, SR
    Burns, PN
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (05) : 1401 - 1412
  • [30] Contrast-enhanced power Doppler sonography of knee synovitis in rheumatoid arthritis: assessment of therapeutic response
    F. Salaffi
    M. Carotti
    P. Manganelli
    E. Filippucci
    G. M. Giuseppetti
    W. Grassi
    Clinical Rheumatology, 2004, 23 : 285 - 290