Value of contrast-enhanced power Doppler sonography using a microbubble

被引:24
|
作者
Kook, SH [1 ]
Kwag, HJ [1 ]
机构
[1] Sungkyunkwan Univ, Kangbuk Samsung Hosp, Dept Radiol, Sch Med,Jongro Gu, Seoul 110108, South Korea
关键词
breast neoplasms; diagnosis; ultrasonography; contrast media; power Doppler ultrasonography;
D O I
10.1002/jcu.10172
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Purpose. The purpose of this study was to prospectively evaluate the usefulness of contrast-enhanced power Doppler sonography (PDUS) using a microbubble echo-enhancing agent in differentiating between malignant and benign small breast lesions. Patients and Methods. Between July 1, 2000, and September 30, 2001, we performed gray-scale sonographic examination of patients in whom diagnostic sonography or screening mammography had revealed solid breast lesions measuring less than 2 cm in the largest dimension. The patients were then examined on PDUS before and after injection of a microbubble contrast agent. The sonographic findings for all 3 techniques, as well as the morphologic features of the Doppler signals for each patient before and after injection of the contrast agent on PDUS, were independently assessed. Each lesion was classified as "benign" or "malignant" on the basis of specific criteria for sonographic interpretation. A hemodynamic study was performed in which time-transit profiles of the Doppler signals on contrast-enhanced PDUS were generated using a computer-assisted program, and the results for each patient were compared with the findings of a histopathologic examination of surgical specimens. Results. Thirty-six patients (35 women and 1 man) with a mean age of 43.5 years (range, 18-69 years) were evaluated. The tumors ranged from 4 to 19 mm in the largest dimension, Histopathologic examination revealed that 19 tumors were benign and 17 were malignant. For morphologic diagnosis of the malignant lesions, the sensitivity of gray-scale sonography was 100%, compared with 29% for PDUS without contrast enhancement. The specificity of gray-scale sonography was 47%, compared with 74% for PDUS without contrast enhancement. Contrast-enhanced PDUS had a sensitivity of 71% and a specificity of 58%. The diagnostic accuracy was 72% for gray-scale sonography, 53% for PDUS without contrast enhancement, and 64% for contrast-enhanced PDUS. The time-transit profiles of the hemodynamic study did not reveal a statistically significant difference in the accuracy rates of contrast-enhanced PDUS between benign and malignant breast lesions. Conclusions. Compared with PDUS without contrast enhancement, contrast-enhanced PDUS provides better visualization of the morphology of vascular Doppler signals; that is characteristic of malignancy and therefore has a higher sensitivity and diagnostic accuracy, albeit a lower specificity. In differentiating between benign and malignant small breast lesions,contrast-enhanced PDUS can be helpful when used with gray-scale sonography and PDUS without contrast enhancement. (C) 2003 Wiley Periodicals, Inc.
引用
收藏
页码:227 / 238
页数:12
相关论文
共 50 条
  • [1] Testicular torsion: Usefulness of contrast-enhanced power Doppler sonography
    Yamaguchi, A
    Hayashi, Y
    Kojima, Y
    Miyagawa, H
    Ito, M
    Kohri, K
    INTERNATIONAL JOURNAL OF UROLOGY, 2005, 12 (09) : 849 - 851
  • [2] Contrast-enhanced power doppler sonography improves imaging of Klatskin tumors
    Bauditz, J
    Ortner, M
    Rickes, S
    Biering, H
    Lochs, H
    Wermke, W
    JOURNAL OF HEPATOLOGY, 2001, 34 : 189 - 189
  • [3] Usefulness of power Doppler and contrast-enhanced sonography in the differentiation of hyperechoic renal masses
    Ascenti, G
    Zimbaro, G
    Mazziotti, S
    Gaeta, M
    Settineri, N
    Scribano, E
    ABDOMINAL IMAGING, 2001, 26 (06): : 654 - 660
  • [4] Usefulness of power Doppler and contrast-enhanced sonography in the differentiation of hyperechoic renal masses
    G. Ascenti
    G. Zimbaro
    S. Mazziotti
    M. Gaeta
    N. Settineri
    E. Scribano
    Abdominal Imaging, 2001, 26 : 654 - 660
  • [5] Renal cortical ischemia in rabbits revealed by contrast-enhanced power Doppler sonography
    Taylor, GA
    Barnewolt, CE
    Adler, BH
    Dunning, PS
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) : 417 - 422
  • [6] Contrast-enhanced color Doppler sonography of uveal melanomas
    Lemke, AJ
    Hosten, N
    Richter, M
    Bechrakis, NE
    Foerster, P
    Puls, R
    Gutberlet, M
    Felix, R
    JOURNAL OF CLINICAL ULTRASOUND, 2001, 29 (04) : 205 - 211
  • [7] Hepatocellular carcinoma treated with radiofrequency ablation: Comparison of pulse inversion contrast-enhanced harmonic sonography, contrast-enhanced power Doppler sonography, and helical CT
    Meloni, MF
    Goldberg, SN
    Livraghi, T
    Calliada, F
    Ricci, P
    Rossi, M
    Pallavicini, D
    Campani, R
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (02) : 375 - 380
  • [8] Therapeutic effect of chemoembolization therapy on hepatocellular carcinoma: Evaluation with contrast-enhanced power Doppler sonography and contrast-enhanced harmonic imaging
    Esteban, JM
    Gil, J
    ACADEMIC RADIOLOGY, 2002, 9 : S382 - S383
  • [9] Liver blood flow measurements using contrast-enhanced power Doppler sonography: An in vitro feasibility study
    Oppo, K
    Ramnarine, KV
    McDicken, WN
    McArdle, C
    RADIOLOGY, 1998, 209P : 233 - 234
  • [10] Contrast-enhanced power Doppler sonography for the differentiation of cystic renal lesions: Preliminary study
    Kim, AY
    Kim, SH
    Kim, YJ
    Lee, IH
    JOURNAL OF ULTRASOUND IN MEDICINE, 1999, 18 (09) : 581 - 588