Prediction of entrained droplet fraction in co-current annular gas-liquid flow in vertical pipes

被引:34
|
作者
Aliyu, Aliyu M. [1 ]
Almabrok, Almabrok A. [2 ]
Baba, Yahaya D. [3 ]
Archibong, Archibong-Eso [4 ]
Lao, Liyun [4 ]
Yeung, Hoi [4 ]
Kim, Kyung Chun [1 ]
机构
[1] Pusan Natl Univ, Sch Mech Engn, Busan 609735, South Korea
[2] Sirte Univ, Fac Engn, Dept Petr Engn, Sirte, Libya
[3] Afe Babalola Univ, Dept Chem & Petr Engn, PMB 5454, Ado Ekiti, Nigeria
[4] Cranfield Univ, Oil & Gas Engn Ctr, Cranfield MK43 0AL, Beds, England
基金
新加坡国家研究基金会;
关键词
Droplet entrainment; Large diameter pipes; Two-phase flow; Sauter mean diameter; Wire Mesh Sensor; 2-PHASE FLOW; MODEL; PHASE; DIAMETER; TRANSITIONS; DEPOSITION; STEADY; WAVES; ONSET; RATES;
D O I
10.1016/j.expthermflusci.2017.03.012
中图分类号
O414.1 [热力学];
学科分类号
摘要
The entrained droplet fraction is an important parameter in annular two-phase flow, as its correlations are key inputs in flow simulation codes for the prediction of pressure drop and critical heat flux or dryout. Investigators have stressed the importance of extending the validity range of current correlations so that more conditions are covered. This could be achieved for example by including fluids with higher viscosities, a wider range of operating pressures, and increase in the size of pipes used for experiments (most of the data in the literature are from pipes of 50 mm diameter and below). In attempt to improve the latter, experiments were conducted in a 101.6 mm gas liquid flow loop at Cranfield University's Oil and Gas Engineering Laboratory and data on the fraction of droplets were collected in the annular flow regime by measuring the film velocity, from which the droplet fraction was calculated. Comparison of the film velocity by this method and by a mass balance showed close agreement. A capacitance Wire Mesh Sensor was used for flow visualisation in order to distinguish between annular and churn flow. In order to arrive at an improved correlation, over 1300 data points were gathered from other published works. These include air water studies where large pipes of up to 127 mm in diameter were used. The others were from small-diameter pipes and for refrigerant, steam water, air water, and air glycerine flows. Since in the annular regime, the gas flow entrains liquid droplets into the core, their presence alters the properties of the gas core. Therefore, accurate predictions are pivotal for the energy efficient design and operation of facilities in the petroleum and nuclear power industry. The correlation obtained here showed good agreement with the collected databank. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:287 / 304
页数:18
相关论文
共 50 条
  • [31] AVERAGE GAS HOLDUP OF GAS-LIQUID UPWARD CO-CURRENT FLOW IN PACKED-BEDS
    KAWASAKI, H
    TANAKA, H
    KAGAKU KOGAKU RONBUNSHU, 1983, 9 (03) : 289 - 294
  • [32] HOLD-UP PREDICTION IN PACKED COLUMNS FOR CO-CURRENT GAS-LIQUID DOWNFLOW
    REYNIER, JP
    CHARPENT.JC
    CHEMICAL ENGINEERING SCIENCE, 1971, 26 (10) : 1781 - &
  • [33] Droplet size measurements in horizontal annular gas-liquid flow
    Simmons, MJH
    Hanratty, TJ
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2001, 27 (05) : 861 - 883
  • [34] Visual measurements of droplet size in gas-liquid annular flow
    Fore, LB
    Ibrahim, BB
    Beus, SG
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2002, 28 (12) : 1895 - 1910
  • [35] Film thickness of vertical upward co-current adiabatic flow in pipes
    Ju, Peng
    Brooks, Caleb S.
    Ishii, Mamoru
    Liu, Yang
    Hibiki, Takashi
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 89 : 985 - 995
  • [36] Co-current stratified gas-liquid downflow - Influence of the liquid flow field on interfacial structure
    Lioumbas, JS
    Paras, SV
    Karabelas, AJ
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2005, 31 (08) : 869 - 896
  • [37] TOWARDS THE UNDERSTANDING OF TRANSFORMATION OF ANNULAR TO DROPLET-ANNULAR GAS-LIQUID FLOW
    Kumar, Parmod
    Mitra, Sushanta K.
    Das, Arup Kumar
    PROCEEDINGS OF THE ASME 14TH INTERNATIONAL CONFERENCE ON NANOCHANNELS, MICROCHANNELS, AND MINICHANNELS, 2016, 2016,
  • [38] Gas-liquid co-current up-flow behaviour through a packed bed
    Zhang, Shouqian
    Zhou, Dasong
    Zhao, Wen
    Teng, Dawei
    Gao Xiao Hua Xue Gong Cheng Xue Bao/Journal of Chemical Engineering of Chinese Universities, 1994, 8 (01): : 67 - 71
  • [39] Associating void fraction signals with bubble clusters features in co-current, upward gas-liquid flow of a non-Newtonian liquid
    Gkotsis, Petros K.
    Evgenidis, Sotiris P.
    Karapantsios, Thodoris D.
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2020, 131
  • [40] Wetted wall fraction of gas-liquid stratified co-current two-phase flow in a horizontal pipe with low liquid loading
    Deendarlianto
    Hudaya, Akhmad Zidni
    Indarto
    Soegiharto, Katya Dara Ozzilenda
    JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2019, 70