Feasibility of Low-volume Injections of Contrast Material with a Body Weight-Adapted Iodine-Dose Protocol in 320-Detector Row Coronary CT Angiography

被引:40
|
作者
Tatsugami, Fuminari [1 ]
Matsuki, Mitsuru [1 ]
Inada, Yuki [1 ]
Kanazawa, Shuji [1 ]
Nakai, Go [1 ]
Takeda, Yoshihiro [2 ]
Morita, Hideaki [3 ]
Takada, Haruhiko [1 ]
Ashida, Kenji [1 ]
Yoshikawa, Shushi [1 ]
Fukumura, Katsunori [1 ]
Narumi, Yoshifumi [1 ]
机构
[1] Osaka Med Coll, Dept Radiol, Takatsuki, Osaka 5698686, Japan
[2] Osaka Med Coll, Dept Internal Med 1, Takatsuki, Osaka 5698686, Japan
[3] Osaka Med Coll, Dept Internal Med 3, Takatsuki, Osaka 5698686, Japan
关键词
Cardiac CT; CT coronary angiography; contrast material; injection method; 320-detector row CT; SPIRAL COMPUTED-TOMOGRAPHY; PATIENT WEIGHT; MASS INDEX; ENHANCEMENT; ATTENUATION; DURATION; TIME;
D O I
10.1016/j.acra.2009.09.010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To investigate the feasibility of low-volume injections of contrast material with a body weight-adapted iodine-dose protocol in computed tomography coronary angiography (CTCA) using a 320-detector row scanner. Materials and Methods: Ninety-eight patients who underwent CTCA in a single heartbeat with electrocardiogram-gating were divided into two groups, receiving 0.8 mL/kg of contrast material injected at a fixed duration of 12 seconds (A; n = 48) or 0.7 mL/kg of contrast material injected at a fixed duration of 10 seconds (13; n = 50); all patients then received 20 mL of saline. Contrast densities were assessed for the ascending aorta, left ventricle, right coronary artery (RCA), and left main coronary artery (LMA). Results: The mean flow rate was 4.00 +/- 0.56 mL/second in group A and 4.06 +/- 0.57 mL/second in group B (P = .51). There were no significant differences in the mean enhancement values of the ascending aorta, LMA and proximal RCA between the two groups. Also, there was no significant difference between the mean enhancement values at the three different levels of the RCA (proximal, middle, and distal segments) (group A; P = .27, group B; P = .07). Conclusion: The use of 0.7 mL/kg of contrast material injected at a fixed duration of 10 seconds was feasible for CTCA using 320-detector row CT, with a sufficient and reliable contrast enhancement in the ascending aorta and coronary artery.
引用
收藏
页码:207 / 211
页数:5
相关论文
共 47 条
  • [21] Dual-source CT coronary angiography involving injection protocol with iodine load tailored to patient body weight and body mass index: estimation of optimal contrast material dose
    Zhu, Xiaomei
    Zhu, Yinsu
    Xu, Hai
    Yang, Guanyu
    Tang, Lijun
    Xu, Yi
    ACTA RADIOLOGICA, 2013, 54 (02) : 149 - 155
  • [22] Optimization of contrast medium protocol in CT coronary arteriography: constant injection dose rate adapted to body weight
    Cao, Lizhen
    Du, Xiangying
    Li, Pengyu
    Sun, Zheng
    Zhang, Qiuhang
    Li, Kuncheng
    ACTA RADIOLOGICA, 2011, 52 (06) : 608 - 612
  • [23] Evaluation of Low-kVp Low-Volume Iodinated Contrast Protocol for Coronary CT Angiography Using Retrospective ECG Gating
    Kapoor, Atul
    Mahajan, Goldaa
    Kapoor, Aprajita
    INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2021, 31 (04): : 910 - 916
  • [24] Reduction of the total injection volume of contrast material with a short injection duration in 64-detector row CT coronary angiography
    Tatsugami, F.
    Kanamoto, T.
    Nakai, G.
    Takeda, Y.
    Morita, H.
    Morinaga, I.
    Yoshikawa, S.
    Narabayashi, I.
    BRITISH JOURNAL OF RADIOLOGY, 2010, 83 (985): : 35 - 39
  • [25] Application of Low Tube Voltage, Low-concentration Contrast Agent Using a 320-row CT in Coronary CT Angiography: Evaluation of Image Quality, Radiation Dose and Iodine Intake
    Yue-ying Pan
    Shu-chang Zhou
    Yu-jin Wang
    Qian Li
    Ting-ting Zhu
    Chun-xia Liu
    Han-xiong Guan
    Current Medical Science, 2020, 40 : 178 - 183
  • [26] Application of Low Tube Voltage, Low-concentration Contrast Agent Using a 320-row CT in Coronary CT Angiography: Evaluation of Image Quality, Radiation Dose and Iodine Intake
    Pan, Yue-ying
    Zhou, Shu-chang
    Wang, Yu-jin
    Li, Qian
    Zhu, Ting-ting
    Liu, Chun-xia
    Guan, Han-xiong
    CURRENT MEDICAL SCIENCE, 2020, 40 (01) : 178 - 183
  • [27] Intravenous contrast material administration at helical 16-detector row CT coronary angiography: Effect of iodine concentration on vascular attenuation
    Cademartiri, F
    Mollet, NR
    van der Lugt, A
    McFadden, EP
    Stijnen, T
    de Feyter, PJ
    Krestin, GP
    RADIOLOGY, 2005, 236 (02) : 661 - 665
  • [28] 320-row CT coronary angiography: effect of 100-kV tube voltages on image quality, contrast volume, and radiation dose
    Zhang, Chuanchen
    Zhang, Zhaoqi
    Yan, Zixu
    Xu, Lei
    Yu, Wei
    Wang, Rui
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (07): : 1059 - 1068
  • [29] 320-row CT coronary angiography: effect of 100-kV tube voltages on image quality, contrast volume, and radiation dose
    Chuanchen Zhang
    Zhaoqi Zhang
    Zixu Yan
    Lei Xu
    Wei Yu
    Rui Wang
    The International Journal of Cardiovascular Imaging, 2011, 27 : 1059 - 1068
  • [30] Coronary CT angiography with 80 kV tube voltage and low iodine concentration contrast agent in patients with low body weight
    Andreini, Daniele
    Mushtaq, Saima
    Conte, Edoardo
    Segurini, Chiara
    Guglielmo, Marco
    Petulla, Maria
    Volpato, Valentina
    Annoni, Andrea
    Baggiano, Andrea
    Formenti, Alberto
    Bartorelli, Antonio L.
    Fiorentini, Cesare
    Pepi, Mauro
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2016, 10 (04) : 322 - 326