Flow-Through Electrochemical Biosensor for the Detection of Listeria monocytogenes Using Oligonucleotides

被引:8
|
作者
Armstrong, Cheryl M. [1 ]
Lee, Joe [1 ]
Gehring, Andrew G. [1 ]
Capobianco, Joseph A. [1 ]
机构
[1] ARS, USDA, Eastern Reg Res Ctr, 600 East Mermaid Lane, Wyndmoor, PA 19038 USA
关键词
biosensor; rapid detection; foodborne pathogen; flow-through transducer; graphite felt; Listeria monocytogenes; Listeria innocua; RAPID SEPARATION; HYBRIDIZATION; ENUMERATION; PATHOGENS; BACTERIA;
D O I
10.3390/s21113754
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Consumption of food contaminated by Listeria monocytogenes can result in Listeriosis, an illness with hospitalization rates of 94% and mortality rates up to 30%. As a result, U.S. regulatory agencies governing food safety retain zero-tolerance policies for L. monocytogenes. However, detection at such low concentrations often requires strategies such as increasing sample size or culture enrichment. A novel flow-through immunoelectrochemical biosensor has been developed for Escherichia coli O157:H7 detection in 1 L volumes without enrichment. The current work further augments this biosensor's capabilities to (1) include detection of L. monocytogenes and (2) accommodate genetic detection to help overcome limitations based upon antibody availability and address specificity errors in phenotypic assays. Herein, the conjugation scheme for oligo attachment and the conditions necessary for genetic detection are laid forth while results of the present study demonstrate the sensor's ability to distinguish L. monocytogenes DNA from L. innocua with a limit of detection of similar to 2 x 10(4) cells/mL, which agrees with prior studies. Total time for this assay can be constrained to <2.5 h because a timely culture enrichment period is not necessary. Furthermore, the electrochemical detection assay can be performed with hand-held electronics, allowing this platform to be adopted for near-line monitoring systems.
引用
收藏
页数:15
相关论文
共 50 条
  • [11] Plasmonic flow-through biosensor using a polymeric substrate
    Buchenauer, Andreas
    Bialon, Magdalena
    Segun, Daniel
    Puettmann, Christiane
    Stein, Christoph
    Barth, Stefan
    Schnakenberg, Uwe
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2014, 24 (03)
  • [12] Detection of Listeria monocytogenes using an automated fiber-optic biosensor:: RAPTOR
    Kim, Giyoung
    Morgan, Mark T.
    Ess, Daniel
    Hahm, Byoung-Kwon
    Kothapalli, Aparna
    Valadez, Angela
    Bhunia, Arun
    ADVANCED NONDESTRUCTIVE EVALUATION I, PTS 1 AND 2, PROCEEDINGS, 2006, 321-323 : 1168 - 1171
  • [13] Flow-through electrochemical immunoassay for targeted bacteria detection
    Chorti, Parthena
    Kazi, Abbas Parvez
    Haque, Al-Monsur Jiaul
    Wiederoder, Michael
    Christodouleas, Dionysios C.
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 351
  • [14] Detection of Listeria monocytogenes by electrochemical impedance spectroscopy
    Radhakrishnan, Rajeswaran
    Dawson, Karen
    Rogers, Shane
    Suni, Ian
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 244
  • [15] Detection of Listeria Monocytogenes by Electrochemical Impedance Spectroscopy
    Radhakrishnan, Rajeswaran
    Jahne, Michael
    Rogers, Shane
    Suni, Ian I.
    ELECTROANALYSIS, 2013, 25 (09) : 2231 - 2237
  • [16] Real Time Flow-Through Biosensor
    Grimaldi, Immacolata Angelica
    Testa, Genni
    Persichetti, Gianluca
    Bernini, Romeo
    SENSORS, 2018, 431 : 177 - 182
  • [17] Electrochemical flow-through system with DNA biosensor for biomedical and food technology applications
    Simkova, Darina
    Labuda, Jan
    2009 2ND INTERNATIONAL SYMPOSIUM ON APPLIED SCIENCES IN BIOMEDICAL AND COMMUNICATION TECHNOLOGIES (ISABEL 2009), 2009, : 181 - 186
  • [18] PlcA-based nanofabricated electrochemical DNA biosensor for the detection of Listeria monocytogenes in raw milk samples
    Kritika Saini
    Ankur Kaushal
    Shagun Gupta
    Dinesh Kumar
    3 Biotech, 2020, 10
  • [19] Ultrasensitive peptide-based multiplexed electrochemical biosensor for the simultaneous detection of Listeria monocytogenes and Staphylococcus aureus
    Shimaa Eissa
    Mohammed Zourob
    Microchimica Acta, 2020, 187
  • [20] Ultrasensitive peptide-based multiplexed electrochemical biosensor for the simultaneous detection of Listeria monocytogenes and Staphylococcus aureus
    Eissa, Shimaa
    Zourob, Mohammed
    MICROCHIMICA ACTA, 2020, 187 (09)