In pediatric CT-guided interventions specific features have to be taken into account. Due to a lack of cooperation or limited ability to cooperate, procedures are often performed using analgosedation or general anesthesia. To provide radiation protection, justified indication for CT-guided intervention is necessary and sonography and MRI are to be preferred whenever possible. CT examinations also need to be dose-adapted with sequential scanning and a tube voltage and tube current reduction compared to pediatric diagnostic CT studies must be ensured. Gonad shields are recommended for male patients. Biopsy device selection depends on the assumed tumor entity since histology and also immunohistochemical, molecular pathological and cytogenetical analysis are necessary to differentiate pediatric tumors (small, round, blue cell tumors). in addition to diagnostic procedures, therapeutic interventions (drainage, injection therapies, neurolysis, and radiofrequency ablation) can also be used in children and can provide an alternative to surgery in selected cases. With justified indications and precise performance, CT-guided interventions can be successful in pediatric patients with limited risks.
引用
收藏
页码:605 / 612
页数:8
相关论文
共 50 条
  • [21] Transoral Approach to CT-Guided C2 Interventions
    Reddy, Arra S.
    DiNobile, Diane
    Orgeta, Juan E.
    Peri, Nagamani
    PAIN PHYSICIAN, 2009, 12 (01) : 253 - 258
  • [22] A gesture-controlled projection display for CT-guided interventions
    Mewes, A.
    Saalfeld, P.
    Riabikin, O.
    Skalej, M.
    Hansen, C.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2016, 11 (01) : 157 - 164
  • [23] Origami Lesion-Targeting Device for CT-Guided Interventions
    Taylor, Austin J.
    Xu, Sheng
    Wood, Bradford J.
    Tse, Zion Tsz Ho
    JOURNAL OF IMAGING, 2019, 5 (02)
  • [24] Polhemus EM tracked Micro Sensor for CT-guided interventions
    Franz, Alfred M.
    Seitel, Alexander
    Cheray, Dominique
    Maier-Hein, Lena
    MEDICAL PHYSICS, 2019, 46 (01) : 15 - 24
  • [25] A gesture-controlled projection display for CT-guided interventions
    A. Mewes
    P. Saalfeld
    O. Riabikin
    M. Skalej
    C. Hansen
    International Journal of Computer Assisted Radiology and Surgery, 2016, 11 : 157 - 164
  • [26] PET/CT Fluoroscopy during PET/CT-Guided Interventions: Initial Experience
    Jiang, Liwei
    Jowkar, Nick
    King, Franklin
    Plishker, William
    Bhagavatula, Sharath K.
    Levesque, Vincent M.
    Kapur, Tina
    Shyn, Paul B.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2023, 34 (08) : 1319 - 1323
  • [27] Percutaneous CT-guided vertebral bone biopsy in children
    Deddeh Ballah
    Els Nijs
    Marc S. Keller
    Xiaowei Zhu
    Ganesh Krishnamurthy
    Anne Marie Cahill
    Pediatric Radiology, 2013, 43 : 582 - 588
  • [28] Percutaneous CT-guided vertebral bone biopsy in children
    Ballah, Deddeh
    Nijs, Els
    Keller, Marc S.
    Zhu, Xiaowei
    Krishnamurthy, Ganesh
    Cahill, Anne Marie
    PEDIATRIC RADIOLOGY, 2013, 43 (05) : 582 - 588
  • [29] Prospective Evaluation of the Radiologist's Hand Dose in CT-Guided Interventions
    Rogits, B.
    Jungnickel, K.
    Loewenthal, D.
    Kropf, S.
    Nekolla, E. A.
    Dudeck, O.
    Pech, M.
    Wieners, G.
    Ricke, J.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2013, 185 (11): : 1084 - 1091
  • [30] Why CT-guided?
    Gruber, H
    Bodner, G
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (03) : 824 - 824