Preparation and evaluation of a lubricious treated cartridge used for implantation of intraocular lenses

被引:1
|
作者
Hu, Can B. [1 ]
Gwon, Arlene [1 ]
Lowery, Mike [1 ]
Makker, Harish [1 ]
Gruber, Lawrence [1 ]
机构
[1] Adv Med Opt, Santa Ana, CA 92705 USA
关键词
lubricious coating; intraocular lenses insertion system; polymer interpenetrating network (IPN); rabbit in vivo study; surface modification;
D O I
10.1163/156856207779116720
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the last decades, many surface modification technologies have been developed in an attempt to improve the function of medical device surfaces by adding or enhancing surface characteristics. These value-added processes included treatment to affect lubricity, hemocompatibility and drug delivery. A unique hydrophilic, lubricious coating was developed to treat hydrophobic polymer surfaces. The coating platforms described are composed of a polyelectrolyte molecular film containing hydrophilic, lubricant molecules. The molecular film is then further cross-linked wish di-functional aldehyde molecules to form an interpenetrating network (IPN). The IPN entraps lubricant molecules in the matrix and provides for prolonged stability of the lubricity. This coating was applied to cartridges which were used to deliver intraocular lenses (IOLs) that replaced the calaractous crystalline lenses in patients In order to determine the safety and effectiveness of the coating, a rabbit in vivo study was designed to evaluate the ease of implantation and postoperative response to implantation of the foldable acrylic IOLs. The performance evaluation of the lubricious treated cartridges focused on the ease of insertion and post-IOL implantation response. It was found that the UNFOLDER (TM) Emerald Insertion System (Advanced Medical Optics) with lubricious treated cartridges generally required lower insertion forces than the standard UNFOLDER (TM) Emerald cartridges. The postoperative inflammatory response following lens extraction and posterior chamber implantation of low (6D), medium (20D) and high (30D) diopter foldable acrylic IOLs with both treated and standard cartridges was mild. Inflammation generally resolved by 3 weeks. Thus, in this animal study, the coating was shown to be effective in assisting the delivery of IOLs through cartridges, without causing any adverse effects.
引用
收藏
页码:179 / 191
页数:13
相关论文
共 50 条
  • [1] IMPLANTATION OF INTRAOCULAR LENSES
    JACOBI, KW
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1978, 172 (02) : 226 - 226
  • [2] EXPERIENCE WITH THE IMPLANTATION OF INTRAOCULAR LENSES
    SCARPATETTI, A
    SPEISER, P
    GESSNER, U
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1982, 180 (05) : 425 - 427
  • [4] Evaluation of raised intraocular pressure post EyeCee One preloaded intraocular lenses implantation
    Wang, Haoyu
    Jong, Joel L. Z.
    Chiu, Stephanie J.
    Kay, William L.
    Tan, Jennifer H. Y.
    EYE, 2023, 37 (15) : 3293 - 3294
  • [5] Evaluation of raised intraocular pressure post EyeCee One preloaded intraocular lenses implantation
    Haoyu Wang
    Joel L. Z. Jong
    Stephanie J. Chiu
    William L. Kay
    Jennifer H. Y. Tan
    Eye, 2023, 37 : 3293 - 3294
  • [6] Implantation of AcrySof acrylic intraocular lenses
    Shugar, JK
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 : 1355 - 1359
  • [7] Pre-clinical Evaluation of Intraocular Lenses through Simulated Implantation
    Gerlach, Mario
    Guthoff, Rudolf F.
    Stachs, Oliver
    Bohn, Sebastian
    Sperlich, Karsten
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2018, 235 (12) : 1332 - 1341
  • [8] Evaluation of pupil dynamics after implantation of artisan phakic Intraocular lenses
    Bootsma, SJ
    Tahzib, NG
    Eggink, FAGJ
    de Brabander, J
    Nuijts, RMMA
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (04) : 367 - 371
  • [9] Sealed implantation of foldable intraocular lenses
    Nath, Dharmendra
    Blumenthal, Eytan Z.
    Sharma, Mohita
    Mimouni, Michael
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2017, 27 (05) : 555 - 558
  • [10] Evaluation of a new soft tipped injector for the implantation of foldable intraocular lenses
    Kleinmann, Guy