Comparison of pore space features by thin sections and X-ray microtomography

被引:9
|
作者
Alves, H. [1 ]
Lima, I. [1 ]
Assis, J. T. [2 ]
Geraldes, M. [3 ]
Lopes, R. T. [1 ]
机构
[1] Univ Fed Rio de Janeiro, Nucl Engn Program, Rio De Janeiro, Brazil
[2] Univ Estado Rio De Janeiro, Mech Engn Program, Nova Friburgo, Brazil
[3] Univ Estado Rio De Janeiro, Dept Geol, Rio De Janeiro, Brazil
关键词
Microtomography; Thin sections; Sediments; Pore network; COMPUTED-TOMOGRAPHY; RESERVOIR; IMAGES;
D O I
10.1016/j.apradiso.2014.08.003
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Microtomographic (mu CT) and thin section (TS) images were analyzed and compared regarding porosity and its distribution along the samples. The results show that mu CT although limited by its resolution, shows relevant information about the distribution of porosity and quantification of connected and non-connected pores. TS have no limitations concerning resolution, but are limited by the experimental data and can only give information about connected pores. These two methods have their own advantages but when paired together they are able to make for a more complete analysis. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:182 / 190
页数:9
相关论文
共 50 条
  • [41] X-ray microtomography, past and present
    Elliott, J. C.
    Davis, G. R.
    Dover, S. D.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VI, 2008, 7078
  • [42] CORRELATIVE LIGHT MICROSCOPY AND X-RAY MICROTOMOGRAPHY OF GROUND SECTIONS OF MINERALISED TISSUES.
    Mills, David
    Boyde, Alan
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XIII, 2021, 11840
  • [43] X-ray microtomography of heart tissue
    Phillips, SJ
    Siegler, S
    Stabinski, M
    Goldman, BI
    FASEB JOURNAL, 2004, 18 (04): : A19 - A19
  • [44] X-ray microtomography of bones and teeth
    Davis, GR
    Wong, FSL
    PHYSIOLOGICAL MEASUREMENT, 1996, 17 (03) : 121 - 146
  • [45] X-ray microtomography shows pore structure and tortuosity in alkali-activated binders
    Provis, John L.
    Myers, Rupert J.
    White, Claire E.
    Rose, Volker
    van Deventer, Jannie S. J.
    CEMENT AND CONCRETE RESEARCH, 2012, 42 (06) : 855 - 864
  • [46] A comparison of different approaches for imaging cracks in composites by X-ray microtomography
    Yu, B.
    Bradley, R. S.
    Soutis, C.
    Withers, P. J.
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2016, 374 (2071):
  • [47] COMPARISON OF MERCURY POROSIMETRY AND X-RAY MICROTOMOGRAPHY FOR POROSITY STUDY OF SANDSTONES
    Kovarova, Katerina
    Sevcik, Robert
    Weishauptova, Zuzana
    ACTA GEODYNAMICA ET GEOMATERIALIA, 2012, 9 (04): : 541 - 549
  • [48] Pore-space characterization of an altered tonalite by X-ray computed microtomography and the 14C-labeled-polymethylmethacrylate method
    Voutilainen, M.
    Siitari-Kauppi, M.
    Sardini, P.
    Lindberg, A.
    Timonen, J.
    JOURNAL OF GEOPHYSICAL RESEARCH-SOLID EARTH, 2012, 117
  • [49] Combined imaging system for X-ray fluorescence and transmission X-ray microtomography
    Ohigashi, T
    Watanabe, N
    Yokosuka, H
    Aoki, S
    SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 : 1352 - 1355
  • [50] Design of X-ray interferometer for phase-contrast X-ray microtomography
    Momose, A
    Hirano, K
    X-RAY MICROSCOPY, PROCEEDINGS, 2000, 507 : 98 - 103