Impact of Deep Learning Reconstruction Combined With a Sharpening Filter on Single-Shot Fast Spin-Echo T2-Weighted Magnetic Resonance Imaging of the Uterus

被引:15
|
作者
Tsuboyama, Takahiro [1 ]
Onishi, Hiromitsu [1 ]
Nakamoto, Atsushi [1 ]
Ogawa, Kazuya [1 ]
Koyama, Yoshihiro [2 ]
Tarewaki, Hiroyuki [2 ]
Tomiyama, Noriyuki [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Radiol, 2-2 Yamadaoka, Suita, Osaka 5650871, Japan
[2] Osaka Univ Hosp, Dept Radiol, Osaka, Japan
关键词
magnetic resonance imaging; T2-weighted imaging; single-shot fast spin-echo; deep learning; filter; uterus; DIAGNOSTIC CONFIDENCE; INCREASED SPEED; QUALITY; MRI;
D O I
10.1097/RLI.0000000000000847
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective This study aimed to evaluate the effects of deep learning (DL) reconstruction and a postprocessing sharpening filter on the image quality of single-shot fast spin-echo (SSFSE) T2-weighted imaging (T2WI) of the uterus. Materials and Methods Fifty consecutive patients who underwent pelvic magnetic resonance imaging were included. Parasagittal T2WI with a slice thickness of 4 mm was obtained with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) and SSFSE sequences (mean scan time, 204 and 22 seconds, respectively). The following 3 types of SSFSE images were reconstructed, and the signal-to-noise ratio (SNR) and tissue contrast were assessed: conventional reconstruction (SSFSE-C), DL reconstruction (SSFSE-DL), and DL with a sharpening filter (SSFSE-DLF). Three radiologists independently assessed image quality, and area under the visual grading characteristics curve (AUC(VGC)) analysis was performed to compare the SSFSE and PROPELLER images. Results Compared with that of the PROPELLER images, the SNR of the SSFSE-C, SSFSE-DL, and SSFSE-DLF images was significantly lower (P < 0.05), significantly higher (P < 0.05), and equivalent, respectively. The SSFSE-DL images exhibited significantly lower contrast between the junctional zone and myometrium than those obtained with the other sequences (P < 0.05). In qualitative comparisons with the PROPELLER images, all 3 SSFSE sequences, SSFSE-DL, and SSFSE-DLF demonstrated significantly higher scores for artifacts, noise, and sharpness, respectively (P < 0.01). The overall image quality of SSFSE-C (mean AUC(VGC), 0.03; P < 0.01) and SSFSE-DL (mean AUC(VGC), 0.23; P < 0.01) was rated as significantly inferior, whereas that of SSFSE-DLF (mean AUC(VGC), 0.69) was equivalent or significantly higher (P < 0.01). Conclusion Using a combination of DL and a sharpening filter markedly increases the image quality of SSFSE of the uterus to the level of the PROPELLER sequence.
引用
收藏
页码:379 / 386
页数:8
相关论文
共 50 条
  • [1] Effect of Deep Learning Reconstruction on Respiratory-triggered T2-weighted MR Imaging of the Liver: A Comparison between the Single-shot Fast Spin-echo and Fast Spin-echo Sequences
    Kiso, Kengo
    Tsuboyama, Takahiro
    Onishi, Hiromitsu
    Ogawa, Kazuya
    Nakamoto, Atsushi
    Tatsumi, Mitsuaki
    Ota, Takashi
    Fukui, Hideyuki
    Yano, Keigo
    Honda, Toru
    Kakemoto, Shinji
    Koyama, Yoshihiro
    Tarewaki, Hiroyuki
    Tomiyama, Noriyuki
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2024, 23 (02) : 214 - 224
  • [2] Single breath-hold T2-weighted MR imaging of the liver: Value of single-shot fast spin-echo and multishot spin-echo echoplanar imaging
    Hori, M
    Murakami, T
    Kim, T
    Kanematsu, M
    Tsuda, K
    Takahashi, S
    Takamura, M
    Hoshi, H
    Nakamura, H
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (05) : 1423 - 1431
  • [3] T2-weighted fast spin-echo magnetic resonance imaging of extraocular muscles
    Demer, Joseph L.
    Dushyanth, Anita
    JOURNAL OF AAPOS, 2011, 15 (01): : 17 - 23
  • [4] Ultrafast T2-weighted imaging of the abdomen and pelvis: Use of single shot fast spin-echo imaging
    Tang, Y
    Yamashita, Y
    Takahashi, M
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (02): : 384 - 390
  • [5] T2-weighted MRI of rectosigmoid carcinoma: Comparison of respiratory-triggered fast spin-echo, breathhold fast-recovery fast spin-echo, and breathhold single-shot fast spin-echo sequences
    Yamashita, Shuhei
    Masui, Takayuki
    Katayama, Motoyuki
    Sato, Kimihiko
    Yoshizawa, Nobuko
    Seo, Hidekazu
    Sakahara, Harumi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (03) : 511 - 516
  • [6] T2-weighted MR imaging of the uterus: Comparison of optimized fast spin-echo and HASTE sequences with conventional fast spin-echo sequences
    Gryspeerdt, S
    Van Hoe, L
    Bosmans, H
    Baert, AL
    Vergote, I
    Marchal, G
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) : 211 - 215
  • [7] Multi-shot echo-planar Flair imaging of brain tumors: comparison of spin-echo T1-weighted, fast spin-echo T2-weighted, and fast spin-echo Flair imaging
    Tomura, N
    Kato, K
    Takahashi, S
    Sashi, R
    Izumi, J
    Narita, K
    Watarai, J
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (02) : 65 - 72
  • [8] Comparison of ultrafast half-Fourier single-shot turbo spin-echo sequence with turbo spin-echo sequences for T2-weighted imaging of the female pelvis
    Yamashita, Y
    Tang, Y
    Abe, Y
    Mitsuzaki, K
    Takahashi, M
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (06): : 1207 - 1212
  • [9] Fat-suppressed T2-weighted MR imaging of the liver: Comparison of respiratory triggered fast spin-echo, breath-hold single-shot fast spin-echo and breath-hold fast-recovery fast spin-echo sequences
    Katayama, M
    Masui, T
    Kobayashi, S
    Ito, T
    Sakahara, H
    Nozaki, A
    RADIOLOGY, 2000, 217 : 587 - 587
  • [10] T2-weighted fast spin-echo MR imaging of liver.
    Mirowitz, SA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) : 263 - 264