Bimodal electric tissue ablation (BETA) - in-vivo evaluation of the effect of applying direct current before and during radiofrequency ablation of porcine liver

被引:10
|
作者
Cockburn, J. F.
Maddern, G. J.
Wemyss-Holden, S. A.
机构
[1] Norfolk & Norwich Univ Hosp, Dept Radiol, Norwich NR4 7UY, Norfolk, England
[2] Norfolk & Norwich Univ Hosp, Dept Surg, Norwich NR4 7UY, Norfolk, England
[3] Univ Adelaide, Queen Elizabeth Hosp, Dept Surg, Woodville, SA 5011, Australia
关键词
D O I
10.1016/j.crad.2006.11.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To examine the effect of applying increasing amounts of direct current (DC) before and during alternating current radiofrequency ablation of porcine liver. MATERIALS AND METHODS: Using a Radiotherapeutics RF3000 generator, a 9 V AC/DC transformer and a 16 G plain aluminium tube as an electrode, a control group of 24 porcine hepatic radiofrequency ablation zones was compared with 24 zones created using a bimodal electric tissue ablation (BETA) technique in three pigs. All ablations were terminated when tissue impedance rose to greater than 999 Omega or radiofrequency energy input felt below 5 W on three successive measurements taken at 1 min intervals. BETA ablations were performed in two phases: an initial phase of variable duration DC followed by a second phase during which standard radiofrequency ablation was applied simultaneously with DC. During this second phase, radiofrequency power input was regulated by the feedback circuitry of the RF3000 generator according to changes in tissue impedance. The diameters (mm) of each ablation zone were measured by two observers in two planes perpendicular to the plane of needle insertion. The mean short axis diameter of each ablation zone was subjected to statistical analysis. RESULTS: With increased duration of prior application of DC, there was a progressive increase in the diameter of the ablation zone (p < 0.001). This effect increased sharply up to 300 s of pre-treatment after which a further increase in diameter occurred, but at a much lesser rate. A maximum ablation zone diameter of 32 mm was produced (control diameters 10-13 mm). CONCLUSION: Applying a 9 V DC to porcine liver in vivo, and continuing this DC application during subsequent radiofrequency ablation, results in larger ablation zone diameters compared with radiofrequency ablation atone. (c) 2006 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:213 / 220
页数:8
相关论文
共 23 条
  • [21] The heat sink effect may cause inadequate tissue ablation: A histological evaluation of microwave, radiofrequency and cryoablation in the rat liver.
    Bhardwaj, N.
    Strickland, A.
    Atanesyan, L.
    Ahmad, F.
    West, K.
    Lloyd, D.
    JOURNAL OF PATHOLOGY, 2006, 210 : 55 - 55
  • [22] Correlation between CT Number shift and tissue temperature change during radiofrequency ablation: an ex-vivo study using bovine liver
    Lee, Dong Leng
    Wong, Yin How
    Cheah, Peng Long
    Tan, Daryl
    Lim, Kok Sing
    Ahmad, Azlan Che
    Sulaiman, Norshazriman
    Abdullah, Basri Johan Jeet
    Yeong, Chai Hong
    18TH ASIA-OCEANIA CONGRESS OF MEDICAL PHYSICS (AOCMP) & 16TH SOUTH-EAST ASIA CONGRESS OF MEDICAL PHYSICS (SEACOMP), 2019, 1248
  • [23] The relationship between impedance change and catheter contact force during radiofrequency ablation:: Evaluation in a porcine Ex Vivo cardiac model using a novel force-sensing irrigated tip ablation catheter
    Thiagalingam, Aravinda
    D'Avila, Andre
    Foley, Lori
    Lambert, Hendrik
    Leo, Giovanni
    Ruskin, Jeremy N.
    Reddy, Vivek Y.
    CIRCULATION, 2007, 116 (16) : 487 - 487