Confidence in Altman-Bland plots: A critical review of the method of differences

被引:264
|
作者
Ludbrook, John [1 ]
机构
[1] Univ Melbourne, Dept Surg, Parkville, Vic 3052, Australia
关键词
fixed bias; heteroscedasticity; homoscedasticity; limits of agreement; prediction interval; proportional bias; repeatability coefficient; COMPARING METHODS; AGREEMENT;
D O I
10.1111/j.1440-1681.2009.05288.x
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
1. Altman and Bland argue that the virtue of plotting differences against averages in method-comparison studies is that 95% confidence limits for the differences can be constructed. These allow authors and readers to judge whether one method of measurement could be substituted for another. 2. The technique is often misused. So I have set out, by statistical argument and worked examples, to advise pharmacologists and physiologists how best to construct these limits. 3. First, construct a scattergram of differences on averages, then calculate the line of best fit for the linear regression of differences on averages. If the slope of the regression is shown to differ from zero, there is proportional bias. 4. If there is no proportional bias and if the scatter of differences is uniform (homoscedasticity), construct 'classical' 95% confidence limits. 5. If there is proportional bias yet homoscedasticity, construct hyperbolic 95% confidence limits (prediction interval) around the line of best fit. 6. If there is proportional bias and the scatter of values for differences increases progressively as the average values increase (heteroscedasticity), log-transform the raw values from the two methods and replot differences against averages. If this eliminates proportional bias and heteroscedasticity, construct 'classical' 95% confidence limits. Otherwise, construct horizontal V-shaped 95% confidence limits around the line of best fit of differences on averages or around the weighted least products line of best fit to the original data. 7. In designing a method-comparison study, consult a qualified biostatistician, obey the rules of randomization and make replicate observations.
引用
收藏
页码:143 / 149
页数:7
相关论文
共 50 条
  • [41] Looking beyond linear regression and Bland-Altman plots: a comparison of the clinical performance of 25-hydroxyvitamin D tests
    Karvaly, Gellert
    Meszaros, Katalin
    Kovacs, Krisztian
    Patocs, Attila
    Sipak, Zoltan
    Vasarhelyi, Barna
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2017, 55 (03) : 385 - 393
  • [42] The Bland-Altman Method Should Not Be Used in Regression Cross-Validation Studies
    O'Connor, Daniel P.
    Mahar, Matthew T.
    Laughlin, Mitzi S.
    Jackson, Andrew S.
    RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2011, 82 (04) : 610 - 616
  • [43] Using bland-altman to assess agreement between two medical devices - Don't forget the confidence intervals!
    Hamilton C.
    Stamey J.
    Journal of Clinical Monitoring and Computing, 2007, 21 (6) : 331 - 333
  • [44] Application of Bland-Altman Method in Comparing Transrectal and Transabdominal Ultrasonography for Estimating Prostate Volume
    Jandaghi, Ali Babaei
    Shakiba, Maryam
    Nasseh, Hamidreza
    Korouji, Yaser
    Esmaeili, Samaneh
    Maboudi, Ali Akbar Khadem
    Khorshidi, Ali
    IRANIAN JOURNAL OF MEDICAL SCIENCES, 2015, 40 (01) : 34 - 39
  • [45] Mass Spectrometry-Based Evaluation of the Bland-Altman Approach: Review, Discussion, and Proposal
    Tsikas, Dimitrios
    MOLECULES, 2023, 28 (13):
  • [46] Interpreting method comparison studies by use of the Bland-Altman plot:: Reflecting the importance of sample size by incorporating confidence limits and predefined error limits in the graphic
    Stöckl, D
    Cabaleiro, DR
    Van Uytfanghe, K
    Thienpont, LM
    CLINICAL CHEMISTRY, 2004, 50 (11) : 2216 - 2218
  • [48] Sample Size for Assessing Agreement between Two Methods of Measurement by Bland-Altman Method
    Lu, Meng-Jie
    Zhong, Wei-Hua
    Liu, Yu-Xiu
    Miao, Hua-Zhang
    Li, Yong-Chang
    Ji, Mu-Huo
    INTERNATIONAL JOURNAL OF BIOSTATISTICS, 2016, 12 (02):
  • [49] Comparison of erythrocyte sedimentation rate measurement by the automated SEDIsystem™ and conventional Westergren method using the Bland and Altman statistical method
    AlFadhli, SM
    Al-Awadhi, AM
    MEDICAL PRINCIPLES AND PRACTICE, 2005, 14 (04) : 241 - 244
  • [50] Validation of home based blood pressure monitoring devices by Bland-Altman limits of agreement with confidence intervals estimation using method of variance estimates recovery and Bootstrap-t method
    Kong, S. L.
    Lui, G. C. S.
    Wu, K. K. Y.
    Fok, A. K. T.
    Chan, C. W. S.
    Lee, S. W. L.
    EUROPEAN HEART JOURNAL, 2016, 37 : 1057 - 1057