共 50 条
Liquid chromatography tandem mass spectrometry assay for fast and sensitive quantification of estrone-sulfate
被引:15
|作者:
Corona, Giuseppe
[1
,2
]
Elia, Caterina
[2
]
Casetta, Bruno
[3
]
Da Ponte, Alessandro
[4
]
Del Pup, Lino
[5
]
Ottavian, Enzo
[6
]
Toffoli, Giuseppe
[2
]
机构:
[1] Ctr Riferimento Oncol, Natl Canc Inst, Clin & Expt Pharmacol Div, I-33081 Aviano, PN, Italy
[2] Ctr Mol Biomed, I-33081 Aviano, PN, Italy
[3] Appl Biosyst Europe, I-20052 Monza, MI, Italy
[4] Natl Canc Inst, Clin Chem & Diagnost Dept, I-33081 Aviano, PN, Italy
[5] Natl Canc Inst, Div Gynecol Oncol, I-33081 Aviano, PN, Italy
[6] Gen Hosp, Clin Pathol Lab, I-33170 Pordenone, PN, Italy
关键词:
Estrone-sulfate;
LC-MS/Ms;
Estrogen;
Menopausal;
Estrogen suppression;
Aromatase inhibitors;
BREAST-CANCER;
AROMATASE INHIBITOR;
HUMAN PLASMA;
ESTRADIOL;
RADIOIMMUNOASSAY;
EXEMESTANE;
THERAPY;
SERUM;
RIA;
D O I:
10.1016/j.cca.2010.01.019
中图分类号:
R446 [实验室诊断];
R-33 [实验医学、医学实验];
学科分类号:
1001 ;
摘要:
Background: The circulating pool of estrone-sulfate is considered as a "reservoir" of slowly-metabolized estrogen that can be exploited for assessing overall individual estrogenicity. The aim of this study was to develop a rapid and sensitive liquid chromatography-tandem mass spectrometry assay for the determination of estrone-sulfate, suitable for routine clinical investigations. Methods: The proposed assay is based on a simple protein precipitation procedure and on a fast measurement with a triple-quadrupole mass spectrometer operating in negative ion mode and in multiple reaction monitoring. The method was assessed for intra- and inter-day precision, accuracy, recovery, and clinical suitability. A comparison with available radioimmunoassay was also performed. Results: The LC-MS/MS method is able to detect estrone-sulfate concentrations <= 1 pg/mL and has a low limit of quantification of 7.8 pg/mL. Intra- and inter-day precision and accuracy were less than 10.5% and 5.0% respectively. The recovery was in the range of 93%-110%. When compared with radioimmunoassay the method resulted more accurate and therefore more suitable for quantifying the estrone-sulfate in different clinical settings, including patients treated with aromatase inhibitors. Conclusions: The proposed LC-MS/MS method represents a convincing alternative to the immunoassay for a fast, cost-effective and reliable measurement of estrone-sulfate in routine clinical investigations and in large epidemiological studies. It may contribute in shedding a new light on the diagnostic value of estrone-sulfate in normal and pathological conditions. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:574 / 580
页数:7
相关论文