Liquid chromatography tandem mass spectrometry assay for fast and sensitive quantification of estrone-sulfate

被引:15
|
作者
Corona, Giuseppe [1 ,2 ]
Elia, Caterina [2 ]
Casetta, Bruno [3 ]
Da Ponte, Alessandro [4 ]
Del Pup, Lino [5 ]
Ottavian, Enzo [6 ]
Toffoli, Giuseppe [2 ]
机构
[1] Ctr Riferimento Oncol, Natl Canc Inst, Clin & Expt Pharmacol Div, I-33081 Aviano, PN, Italy
[2] Ctr Mol Biomed, I-33081 Aviano, PN, Italy
[3] Appl Biosyst Europe, I-20052 Monza, MI, Italy
[4] Natl Canc Inst, Clin Chem & Diagnost Dept, I-33081 Aviano, PN, Italy
[5] Natl Canc Inst, Div Gynecol Oncol, I-33081 Aviano, PN, Italy
[6] Gen Hosp, Clin Pathol Lab, I-33170 Pordenone, PN, Italy
关键词
Estrone-sulfate; LC-MS/Ms; Estrogen; Menopausal; Estrogen suppression; Aromatase inhibitors; BREAST-CANCER; AROMATASE INHIBITOR; HUMAN PLASMA; ESTRADIOL; RADIOIMMUNOASSAY; EXEMESTANE; THERAPY; SERUM; RIA;
D O I
10.1016/j.cca.2010.01.019
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The circulating pool of estrone-sulfate is considered as a "reservoir" of slowly-metabolized estrogen that can be exploited for assessing overall individual estrogenicity. The aim of this study was to develop a rapid and sensitive liquid chromatography-tandem mass spectrometry assay for the determination of estrone-sulfate, suitable for routine clinical investigations. Methods: The proposed assay is based on a simple protein precipitation procedure and on a fast measurement with a triple-quadrupole mass spectrometer operating in negative ion mode and in multiple reaction monitoring. The method was assessed for intra- and inter-day precision, accuracy, recovery, and clinical suitability. A comparison with available radioimmunoassay was also performed. Results: The LC-MS/MS method is able to detect estrone-sulfate concentrations <= 1 pg/mL and has a low limit of quantification of 7.8 pg/mL. Intra- and inter-day precision and accuracy were less than 10.5% and 5.0% respectively. The recovery was in the range of 93%-110%. When compared with radioimmunoassay the method resulted more accurate and therefore more suitable for quantifying the estrone-sulfate in different clinical settings, including patients treated with aromatase inhibitors. Conclusions: The proposed LC-MS/MS method represents a convincing alternative to the immunoassay for a fast, cost-effective and reliable measurement of estrone-sulfate in routine clinical investigations and in large epidemiological studies. It may contribute in shedding a new light on the diagnostic value of estrone-sulfate in normal and pathological conditions. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:574 / 580
页数:7
相关论文
共 50 条
  • [1] A simple and sensitive liquid chromatography-tandem mass spectrometry assay for the quantification of ertapenem in microdialysate
    Lefeuvre, Sandrine
    Venisse, Nicolas
    Marchand, Sandrine
    Bachelet, Mickael
    Couet, William
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 862 (1-2): : 242 - 245
  • [2] Sensitive and rapid liquid chromatography/tandem mass spectrometry assay for the quantification of amlodipine in human plasma
    Nirogi, Ramakrishna V. S.
    Kandikere, Vishwottam N.
    Mudigonda, Koteshwara
    Shukla, Manj
    Maurya, Santosh
    BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (09) : 833 - 842
  • [3] Development of a highly sensitive method for the quantification of estrone and estradiol in serum by liquid chromatography tandem mass spectrometry without derivatization
    Fiers, Tom
    Casetta, Bruno
    Bernaert, Brigitte
    Vandersypt, Eric
    Debock, Martine
    Kaufman, Jean-Marc
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 893 : 57 - 62
  • [4] Liquid chromatography/tandem mass spectrometry assay for the quantification of troxerutin in human plasma
    Liu, Fei
    Xu, Yu
    Rui, Lei
    Gao, Shu
    Dong, Haijun
    Guo, Qingxiang
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (23) : 3522 - 3526
  • [5] Sensitive liquid chromatography tandem mass spectrometry method for the quantification of Quetiapine in plasma
    Nirogi, Ramakrishna
    Bhyrapuneni, Gopinadh
    Kandikere, Vishwottam
    Mudigonda, Koteshwara
    Ajjala, Devender
    Mukkanti, K.
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (10) : 1043 - 1055
  • [6] Quantification of clopidogrel in human plasma by sensitive liquid chromatography/tandem mass spectrometry
    Nirogi, RVS
    Kandikere, VN
    Shukla, M
    Mudigonda, K
    Maurya, S
    Boosi, R
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (11) : 1695 - 1700
  • [7] Development and validation of a sensitive liquid chromatography/electrospray tandem mass spectrometry assay for the quantification of olanzapine in human plasma
    Nirogi, Ramakrishna V. S.
    Kandikere, Vishwottam N.
    Shukla, Manoj
    Mudigonda, Koteshwara
    Maurya, Santosh
    Boosi, Ravikumar
    Yeffamilli, Anjaneyulu
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (03) : 935 - 942
  • [8] Evolution of 17-b-estradiol, estrone and estrone-sulfate concentrations in late pregnancy of different breeds of mares using Liquid Chromatography and Mass Spectrometry
    Ledeck, Joy
    Dufour, Patrice
    Evrard, Elise
    Le Goff, Caroline
    Peeters, Stephanie
    Brutinel, Flore
    Egyptien, Sophie
    Deleuze, Stefan
    Cavalier, Etienne
    Ponthier, Jerome
    THERIOGENOLOGY, 2022, 189 : 86 - 91
  • [9] Sensitive liquid chromatography/mass spectrometry assay for the quantification of azithromycin in human plasma
    Liu, Fei
    Xu, Yu
    Huang, Jinchang
    Gao, Shu
    Guo, Qingxiang
    BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (12) : 1272 - 1278
  • [10] Development of a liquid chromatography/tandem mass spectrometry assay for the quantification of rabeprazole in human plasma
    Huang, JC
    Xu, Y
    Gao, S
    Rui, L
    Guo, QX
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (16) : 2321 - 2324