A rapid method for on-line solid-phase extraction and determination of dioscin in human plasma using a homemade monolithic sorbent combined with high-performance liquid chromatography

被引:8
|
作者
Peng, Shan [1 ,2 ]
Bai, Ligai [1 ,2 ]
Shi, Xiaoqian [1 ]
Li, Mingxue [1 ,2 ]
Wang, Laisen [1 ,2 ]
Sun, Fanrong [1 ,2 ]
Liu, Haiyan [1 ,2 ]
机构
[1] Hebei Univ, Coll Pharmaceut Sci, 180 Wusi East Rd, Baoding 071002, Hebei, Peoples R China
[2] Hebei Univ, Key Lab Med Chem & Mol Diag, Minist Educ, Baoding 071002, Hebei, Peoples R China
基金
中国国家自然科学基金;
关键词
On-line SPE-HPLC; Polymer monolithic sorbent; Dioscin; Dioscorea nipponica rhizome; Ethylene glycol phenyl ether acrylate; TANDEM MASS-SPECTROMETRY; RAT PLASMA; DIOSCOREA SAPONINS; STEROIDAL SAPONINS; SAMPLE PREPARATION; MEDICINE; MS/MS; PHARMACOKINETICS; MICROEXTRACTION; RESIDUES;
D O I
10.1007/s00216-019-02256-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A phenyl-based polymer monolithic column was prepared via free radical polymerization in a stainless steel column with the size of 4.6 mm i.d. x 50 mm, using ethylene glycol phenyl ether acrylate as the monomer. The resulting monolithic column shows high porosity of 73.42% and relative uniform pore structure, as characterized by mercury porosimetry and scanning electron microscopy, respectively. The optimized polymer monolith column was used for on-line solid-phase extraction prior to the reversed phase mode HPLC-UV analysis for the determination of dioscin in human plasma, using a COSMOSIL C18 column (4.6 mm x 150 mm, 4.5 mu m). Water was used to wash non-retained components from the SPE sorbent, and methanol water (80:20, V/V) was used as the mobile phase for isocratic elution of dioscin. The maximum adsorbed quantity of dioscin to the SPE column is 6.79 mg/g, which is high enough for the quantitative analysis of dioscin in plasma, due to the low content of dioscin in plasma. The method was validated by assessing the linearity, lower limit of quantification, intra- and inter-day precision, accuracy, and repeatability. The developed method was applied for the analysis of dioscin in plasma from a volunteer who had orally administered an aqueous extract of dioscorea nipponica rhizome, showing the method capable of detecting dioscin in the plasma. These results show that the developed method is a rapid method for on-line solid-phase extraction and determination of dioscin from plasma, exhibiting good selectivity with hydrogen bond interaction and hydrophobic interaction, good clean-up ability, cost-saving, and time-saving.
引用
收藏
页码:473 / 480
页数:8
相关论文
共 50 条
  • [31] Improved method for determination of β-phenylethylamine in human plasma by solid-phase extraction and high-performance liquid chromatography with fluorescence detection
    Kawamura, K
    Matsumoto, T
    Nakahara, T
    Hirano, M
    Uchimura, H
    Maeda, H
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2000, 23 (13) : 1981 - 1993
  • [32] On-line solid-phase extraction and high-performance liquid chromatographic determination of chlorthalidone in urine
    Salado, S
    VeraAvila, LE
    JOURNAL OF CHROMATOGRAPHY B, 1997, 690 (1-2): : 195 - 202
  • [33] Determination of melatonin in human plasma with solid-phase extraction, high-performance liquid chromatography and fluorescence detection
    Römsing, S
    Ulfberg, J
    Bergqvist, Y
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2003, 63 (01): : 81 - 88
  • [34] Determination of penicillin-V in human plasma by high-performance liquid chromatography and solid-phase extraction
    Krauwinkel, WJJ
    VolkersKamermans, NJ
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 679 (1-2): : 129 - 135
  • [35] On-line preconcentration with solid-phase extraction for the determination of phenol and chlorophenols in aqueous samples by high-performance liquid chromatography
    Jung, MW
    Lee, DW
    Rhee, JS
    Paeng, KJ
    ANALYTICAL SCIENCES, 1996, 12 (06) : 981 - 984
  • [36] Determination of Ligustrazine in Human Plasma by High Performance Liquid Chromatography with Solid-Phase Extraction
    Weng Weiyu
    Shen Teng
    Xu Huinan
    Zhang Jianfang
    Huang Jianming
    Huang Zhaochang
    Cai Jia
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2005, 23 (03) : 276 - 278
  • [37] Determination of apovincaminic acid in human plasma by high-performance liquid chromatography using solid-phase extraction and ultraviolet detection
    Chen, J
    Cai, J
    Tao, WX
    Mei, N
    Cao, SL
    Jiang, XG
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 830 (02): : 201 - 206
  • [38] DETERMINATION OF TENOXICAM IN HUMAN PLASMA USING SOLID-PHASE EXTRACTION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION
    CARLUCCI, G
    MAZZEO, P
    PALUMBO, G
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (04): : 683 - 695
  • [39] Quantitation of psilocin in human plasma by high-performance liquid chromatography and electrochemical detection:: comparison of liquid-liquid extraction with automated on-line solid-phase extraction
    Lindenblatt, H
    Krämer, E
    Holzmann-Erens, P
    Gouzoulis-Mayfrank, E
    Kovar, KA
    JOURNAL OF CHROMATOGRAPHY B, 1998, 709 (02): : 255 - 263
  • [40] Determination of 18 veterinary antibiotics in environmental water using high-performance liquid chromatography-q-orbitrap combined with on-line solid-phase extraction
    Kim, Chansik
    Ryu, Hong-Duck
    Chung, Eu Gene
    Kim, Yongseok
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1084 : 158 - 165