Validity of echocardiography for detection of left ventricular thrombus with surgical validation in patients awaiting durable left ventricular assist device

被引:2
|
作者
Bae, David J. [1 ]
Wadia, Subeer K. [1 ]
Kim, Juka S. [2 ]
Moreno, Elan [1 ]
Ardehali, Reza [1 ]
Shemin, Richard J. [3 ]
Kwon, Murray H. [3 ]
机构
[1] Univ Calif Los Angeles, Div Cardiol, Los Angeles, CA USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, Div Cardiothorac Surg, Los Angeles, CA USA
关键词
echocardiography; left ventricular assist device; left ventricular thrombus; off‐ pump; 2-DIMENSIONAL ECHOCARDIOGRAPHY; CONTRAST ECHOCARDIOGRAPHY; IMPLANTATION;
D O I
10.1111/jocs.15662
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective Unrecognized left ventricular thrombi (LVT) can have devastating clinical implications and precludes patients with end-stage heart failure from undergoing left ventricular assist device (LVAD) implantation without cardiopulmonary bypass assistance. We assessed the reliability of an echocardiogram to diagnose LVT in patients with end-stage heart disease who underwent LVAD implantation. Methods A single-center retrospective study evaluated 232 consecutive adult patients requiring implantation of durable LVADs between 2005 and 2019. The validity of preoperative transthoracic echocardiogram (TTE) and intraoperative transesophageal echocardiogram (TEE) for diagnosing LVT was compared to direct inspection at the time of LVAD implantation. Results There were 232 patients that underwent LVAD implantation, with 226 patients (97%) receiving a preoperative TTE. Of those 226 patients, 32 patients (14%) received ultrasound enhancing agents (UEA). Intraoperative TEE images were available in 195 patients (84%). The sensitivity of TTE without UEA was 22% and specificity was 90% for detecting LVT, compared to 50% and 86%, respectively, for TTE with UEA. For intraoperative TEE, the sensitivity and specificity were 46% and 96%, respectively. The false omission rate ranged from 4% to 8% for all modalities of echocardiography. Conclusion Among patients undergoing LVAD implantation, preoperative TTE and intraoperative TEE had poor sensitivity for LVT detection. Up to 8% of echocardiograms were incorrectly concluded to be negative for LVT on surgical validation. The low sensitivity and positive predictive value for diagnosing LVT suggest that echocardiography has limited reliability in this cohort of patients who are at high risk of LVT formation and its subsequent complications.
引用
收藏
页码:2722 / 2728
页数:7
相关论文
共 50 条
  • [31] Intraoperative bronchoscopic visualization of left ventricular assist device thrombus
    Yost, Gardner
    Bhat, Geetha
    Modi, Sejal
    Pappas, Pat
    Tatooles, Antone
    PERFUSION-UK, 2016, 31 (05): : 433 - 435
  • [32] Incidence and current management of left ventricular assist device thrombus
    Sultan, M.
    Flores, E.
    Verma, D.
    Argarwal, S.
    Rayyan, E.
    Loli, A.
    Cherukuri, M.
    EUROPEAN HEART JOURNAL, 2017, 38 : 1046 - 1047
  • [33] Special Considerations for Durable Left Ventricular Assist Device Use in Small Patients
    Bourque, Kevin
    Fraser, Catherine E.
    Lorts, Angela
    Molina, Ezequiel J.
    Kormos, Robert L.
    Naka, Yoshifumi
    Sheikh, Farooq H.
    Uriel, Nir Y.
    Morales, David L. S.
    ASAIO JOURNAL, 2022, 68 (05) : 619 - 622
  • [34] Durable Left Ventricular Assist Device Implantation in Jehovah's Witness Patients
    Chickerillo, K.
    Meehan, K.
    Chinco, A.
    LaBuhn, C.
    Moore, K.
    Okray, J.
    Wright, N.
    Hwang, V.
    Jain, S.
    Jeevanandam, V.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2024, 43 (04): : S280 - S280
  • [35] Characteristics and Outcomes of Candidemia in Patients with Durable Left Ventricular Assist Device Support
    Broderick, Kaitlyn L.
    Peters, Carli J.
    Mazurek, Jeremy A.
    Wald, Joyce
    Zhang, Robert S.
    Atluri, Pavan
    Urgo, Kim
    Goldberg, Lee
    Blumberg, Emily A.
    Weikert, Blair C.
    Birati, Edo Y.
    ASAIO JOURNAL, 2022, 68 (08) : 1044 - 1047
  • [36] Right ventricular analysis by speckle tracking echocardiography in patients undergoing left ventricular assist device
    Cameli, M.
    Lisi, M.
    Righini, F. M.
    Focardi, M.
    Maccherini, M.
    Sani, G.
    Galderisi, M.
    Mondillo, S.
    EUROPEAN HEART JOURNAL, 2012, 33 : 69 - 69
  • [37] Medical Management of Patients With a Left Ventricular Assist Device for the Non-Left Ventricular Assist Device Specialist
    DeVore, Adam D.
    Patel, Priyesh A.
    Patel, Chetan B.
    JACC-HEART FAILURE, 2017, 5 (09) : 621 - 631
  • [38] Left Ventricular Assist Device Implantation Combined with Surgical Ventricular Reconstruction
    Chernyavskiy, Alexander M.
    Marchenko, Andrey V.
    Lomivorotov, Vladimir V.
    Doronin, Dmitriy
    Alsov, Sergey A.
    Nesmachnyy, Alexey
    TEXAS HEART INSTITUTE JOURNAL, 2012, 39 (05) : 627 - 629
  • [39] Bloodstream Infections in Left Ventricular Assist Device Recipients Awaiting Transplantation
    Kyvernitakis, A.
    Pappas, O.
    Farmakiotis, D.
    Horn, E. T.
    Benza, R. L.
    Bailey, S. H.
    Agarwal, R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (04): : S135 - S135
  • [40] Design, analysis and validation of left ventricular assist device
    Antony, Martin
    Tom, Melvin
    Varghese, Jacob
    Joseph, Sebin
    Polachan, Sheen