Small Signal Dynamics of DFIG-Based Wind Turbines During Riding Through Symmetrical Faults in Weak AC Grid

被引:118
|
作者
Hu, Jiabing [1 ,2 ]
Wang, Bo [1 ,2 ]
Wang, Weisheng [3 ]
Tang, Haiyan [4 ]
Chi, Yongning [5 ]
Hu, Qi [1 ,2 ]
机构
[1] Huazhong Univ Sci & Technol, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Peoples R China
[2] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, Wuhan 430074, Peoples R China
[3] China Elect Power Res Inst, Renewable Energy Dept, Beijing 100192, Peoples R China
[4] China Elect Power Res Inst, Beijing 100192, Peoples R China
[5] China Elect Power Res Inst, Renewable Energy Res Center, Beijing 100192, Peoples R China
基金
中国国家自然科学基金;
关键词
Doubly fed induction generator (DFIG); high-impedance grids; low-voltage ride-through (LVRT); phase-locked loop (PLL); rotor current controller; small-signal stability; REACTIVE POWER REGULATION; FED INDUCTION GENERATOR; STABILITY; CONVERTERS; IMPACT;
D O I
10.1109/TEC.2017.2655540
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Instability issues of the grid-connected doubly fed induction generator (DFIG) based wind turbines (WTs) during low-voltage ride-through (LVRT) have got little attention yet. In this paper, the small-signal behavior of DFIG WTs attached to weak ac grid with high impedances during the period of LVRT is investigated, with special attention paid to the rotor-side converter. First, based on the studied LVRT strategy, the influence of the high-impedance grid is summarized as the interaction between phase-looked loop (PLL) and rotor current controller (RCC). As modal analysis result indicates that the underdamped poles are dominated by PLL, complex torque coefficient method, which is conventionally applied in power system to study the interaction between mechanical and electrical subsystems of synchronous generator, is generalized to analyze how the PLL-RCC interaction influence the phase motion of PLL. Then, the concerned small-signal stability of the PLL-synchronized DFIG system can be discerned by the developed complex phase coefficients. Impacts of PLL's and RCC's parameters are highlighted, as well as the system's operating conditions during LVRT. Finally, the analytical result is validated by experiments.
引用
收藏
页码:720 / 730
页数:11
相关论文
共 50 条
  • [31] Coupling DFIG-Based Wind Turbines with the Grid under Voltage Imbalance Conditions
    Sobhy, Ahmed
    Abo-Khalil, Ahmed G.
    Lei, Dong
    Salameh, Tareq
    Merabet, Adel
    Alkasrawi, Malek
    [J]. SUSTAINABILITY, 2022, 14 (09)
  • [32] Dynamic Characteristic of The Drive Train of DFIG Wind Turbines During Grid Faults
    Yao Xingjia
    Liang Lizhe
    Xing Zuoxia
    Liang Lizhe
    [J]. ICICTA: 2009 SECOND INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTATION TECHNOLOGY AND AUTOMATION, VOL II, PROCEEDINGS, 2009, : 503 - +
  • [33] Blackstart and Fault Ride -Through Capability of DFIG-Based Wind Turbines
    Dang, Hoang P.
    Pico, Hugo N. Villegas
    [J]. 2023 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, PESGM, 2023,
  • [34] Impedance Modeling and Key Stabilizing Factor Evaluation of DFIG-based Wind Turbines With Negative Sequence Control During Weak Power Grid
    Wu H.
    Xu H.
    Zhang L.
    Li Z.
    Wang Y.
    [J]. Gaodianya Jishu/High Voltage Engineering, 2023, 49 (06): : 2516 - 2528
  • [35] Inductance-Emulating Control for DFIG-Based Wind Turbine to Ride-Through Grid Faults
    Zhu, Donghai
    Zou, Xudong
    Deng, Lu
    Huang, Qingjun
    Zhou, Shiying
    Kang, Yong
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (11) : 8514 - 8525
  • [36] Inductance-Simulating Control for DFIG-Based Wind Turbine to Ride-through Grid Faults
    Zhu, Donghai
    Zou, Xudong
    Kang, Yong
    Deng, Lu
    Huang, Qingjun
    [J]. APEC 2016 31ST ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, 2016, : 3521 - 3525
  • [37] Synchronization Instability Mechanism and Damping Enhancement Control for DFIG-Based Wind Turbine During Grid Faults
    Yang, Yihang
    Zhu, Donghai
    Zhou, Dangsheng
    Zou, Xudong
    Hu, Jiabing
    Kang, Yong
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (10) : 12104 - 12115
  • [38] Improving the LVRT Capability of the DFIG-Based Wind Turbines during Fault
    Madani, Seyed Mohammad
    Sadeghi, Ramtin
    Abadi, Behnaz Kharkan Mehdi
    [J]. 2015 6TH POWER ELECTRONICS, DRIVES SYSTEMS & TECHNOLOGIES CONFERENCE (PEDSTC), 2015, : 503 - 508
  • [39] Hybrid Power Synchronization Control Strategy of DFIG-based Wind Turbines and Its Stability Analysis Under Weak Grid
    Li M.
    Xie Z.
    Gao X.
    Yang S.
    Zhang X.
    [J]. Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (21): : 8388 - 8399
  • [40] Stability of DC-Link Voltage Control for Paralleled DFIG-Based Wind Turbines Connected to Weak AC Grids
    Wang, Dong
    Hou, Yunhe
    Hu, Jiabing
    [J]. 2016 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PESGM), 2016,