Long-Term Efficacy, Visual Performance and Patient Reported Outcomes with a Trifocal Intraocular Lens: A Six-Year Follow-up

被引:15
|
作者
Fernandez, Joaquin [1 ]
Rodriguez-Vallejo, Manuel [1 ]
Martinez, Javier [1 ]
Burguera, Noemi [1 ]
Pinero, David P. [2 ,3 ]
机构
[1] VITHAS Almeria Hosp, Dept Ophthalmol, Qvis, Almeria 04120, Spain
[2] Univ Alicante, Dept Opt Pharmacol & Anat, Alicante 03009, Spain
[3] Vithas Medimar Int Hosp, Dept Ophthalmol IMQO Oftalmar, Alicante 03016, Spain
关键词
multifocal intraocular lens; long-term; safety; efficacy; defocus curve; light distortion; IMPLANTATION; SATISFACTION; SURGERY; QUALITY; VF-14;
D O I
10.3390/jcm10092009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
(1) Background: To evaluate the efficacy at 6 years postoperative after the implantation of a trifocal intraocular lens (IOL) AT Lisa Tri 839MP. The secondary objective was to evaluate the contrast sensitivity defocus curve (CSDC), light distortion analysis (LDA), and patient reported outcomes (PROs). (2) Methods: Sixty-two subjects participated in phone call interviews to collect data regarding a visual function questionnaire (VF-14), a patient reported spectacle independence questionnaire (PRSIQ), and questions related to satisfaction and decision to be implanted with the same IOL. Thirty-seven of these subjects were consecutively invited to a study visit for measurement of their visual acuity (VA), CSDC, and LDA. (3) Results: The mean monocular distance corrected VA was -0.05, 0.08, and 0.05 logMAR at far and distances of 67 cm and 40 cm, respectively. These VAs were significantly superior to those reported in previous literature (p < 0.05). The total area under the CSDC was 2.29 logCS/m(-1) and the light distortion index 18.82%. The mean VF-14 score was 94.73, with 19.4% of subjects requiring spectacles occasionally for near distances, and 88.9% considering the decision of being operated again; (4) Conclusions: Long-term AT LISA Tri 839MP IOL efficacy results were equal or better than those reported 12 months postoperatively in previous studies. The spectacle independence and satisfaction rates were comparable to those reported in short-term studies.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] What Are the Patient-reported Outcomes of Trapeziectomy and Tendon Suspension at Long-term Follow-up?
    Wolf, Jennifer Moriatis
    Turkiewicz, Aleksandra
    Englund, Martin
    Karlsson, Jon
    Arner, Marianne
    Atroshi, Isam
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2021, 479 (09) : 2009 - 2018
  • [22] Clinical efficacy evaluation of the implantation of a diffractive trifocal intraocular lens in high myopia eyes: Two-year follow-up
    Liu, Shasha
    Wang, Yao
    Kang, Tingting
    Lv, Wenhao
    Ma, Ruonan
    Yu, Ying
    Yin, Lianrong
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2025, 73 (01)
  • [23] Long-term pathological follow-up of 2-loop iridocapsular intraocular lens
    Burrow, Michael K.
    Werner, Liliana
    Maddula, Surekha
    Ness, Peter J.
    Davis, Don
    Mamalis, Nick
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (02): : 409 - 412
  • [24] Long-term pathological follow-up of obsolete design: Pannu universal intraocular lens
    Davis, Don
    Werner, Liliana
    Strenk, Susan
    Strenk, Lawrence
    Yeh, Oliver
    Mamalis, Nick
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (03): : 512 - 516
  • [25] A LONG-TERM FOLLOW-UP OF PATIENTS WITH POSTERIOR-CHAMBER INTRAOCULAR-LENS
    FEDOROV, SN
    ZAKHAROV, VD
    KOROEV, OA
    VESTNIK OFTALMOLOGII, 1983, (05) : 15 - &
  • [26] Black diaphragm aniridia intraocular lens for congenital aniridia: Long-term follow-up
    Reinhard, T
    Engelhardt, S
    Sundmacher, R
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (03): : 375 - 381
  • [27] Posterior chamber phakic intraocular lens to correct myopia: Long-term follow-up
    Torun, Necip
    Bertelmann, Eckart
    Klamann, Matthias K. J.
    Maier, Anna-Karina
    Liekfeld, Anja
    Gonnermann, Johannes
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (07): : 1023 - 1028
  • [28] Long-term follow-up after Artisan phakic intraocular lens implantation in hyperopia
    Van Rijn, Gwyneth A.
    Jongman, Henri P.
    Wijnen, Jasper
    Luyten, Gregorius P. M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [29] Stent malapposition is associated with unfavorable long-term outcomes in patients treated by primary coronary angioplasty: six-year follow-up of ROBUST study
    Jakl, M.
    Cervinka, P.
    Kala, P.
    Kanovsky, J.
    Kupec, A.
    Vanek, J.
    Bezerra, H. G.
    Schnell, A.
    Costa, M. A.
    EUROPEAN HEART JOURNAL, 2018, 39 : 652 - 652
  • [30] Intraocular lens movement in-vivo: Long term follow-up
    Banerjee, G
    Patel, CK
    Rosen, PJ
    Brown, NA
    Bron, AJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 905 - 905