Calibration of the degree of linear polarization measurement of polarized radiometer using solar light

被引:23
|
作者
Li, Zhengqiang [1 ,2 ]
Blarel, Luc [1 ]
Podvin, Thierry [1 ]
Goloub, Philippe [1 ]
Chen, Ligang [3 ]
机构
[1] Univ Lille 1, Opt Atmospher Lab, F-59655 Villeneuve Dascq, France
[2] Chinese Acad Sci, Inst Remote Sensing Applicat, State Key Lab Remote Sensing Sci, Beijing 100101, Peoples R China
[3] Chinese Acad Sci, Key Lab Opt Calibrat & Characterizat, Anhui Inst Opt & Fine Mech, Hefei 230031, Peoples R China
关键词
POLARIMETRIC MEASUREMENTS; AEROSOL PROPERTIES; SCATTERING; RETRIEVAL; SATELLITE;
D O I
10.1364/AO.49.001249
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We establish a polarimetric reference for the degree of linear polarization (DOLP) measurement calibration, based on direct and reflected solar light, with a theoretical error of about 0.0012. This calibration source can be used to calibrate polarized radiometers instead of complex laboratory devices and can respond from UV to near infrared wavelengths. A two-step method for calibrating the DOLP measurement is proposed and applied to a ground-based polarized radiometer. The first step is correcting the transmittance difference between polarizer units using the direct solar beam, while the second step corrects possible bias in DOLP measurement using the reflected solar light as a reference. Based on instrument characterization, calibration results obtained with the new polarized sun-sky radiometer, CE-318-DP, are discussed and compared with laboratory results. (C) 2010 Optical Society of America
引用
收藏
页码:1249 / 1256
页数:8
相关论文
共 50 条
  • [41] Reflectance Measurement of EUV Mirrors with s- and p-Polarized Light Using Polarization Control Units
    Harada, Tetsuo
    Watanabe, Takeo
    INTERNATIONAL CONFERENCE ON EXTREME ULTRAVIOLET LITHOGRAPHY 2018, 2018, 10809
  • [42] Design, calibration, and characterization of a field radiometer using light-emitting diodes as detectors
    Czapla-Myers, Jeffrey S.
    Thome, Kurtis J.
    Biggar, Stuart F.
    APPLIED OPTICS, 2008, 47 (36) : 6753 - 6762
  • [43] Measurement and processing of linear polarization in solar flares - A comparison of two methods
    Kotrc, P
    Firstova, NM
    Kashapova, LK
    Kupryakov, YA
    SOLAR VARIABILITY: FROM CORE TO OUTER FRONTIERS, VOLS 1 & 2, 2002, 506 : 947 - 950
  • [44] Quantum measurement of the degree of polarization of a light beam -: art. no. 167902
    Legré, M
    Wegmüller, M
    Gisin, N
    PHYSICAL REVIEW LETTERS, 2003, 91 (16) : 167902 - 167902
  • [45] Calibration of high spectral resolution solar radiometer for ground-based measurement of atmospherical CO2
    Liu, Qiang
    Song, Maoxin
    Chen, Dihu
    Guangxue Xuebao/Acta Optica Sinica, 2014, 34 (02):
  • [46] Valley polarization in biased bilayer graphene using circularly polarized light
    Friedlan, A.
    Dignam, M. M.
    PHYSICAL REVIEW B, 2021, 103 (07)
  • [47] DECOMPOSITION OF VOLUME SCATTERING, POLARIZED LIGHT AND CHLOROPHYLL FLUORESCENCE BY IN-SITU POLARIZATION MEASUREMENT
    Huang, Changping
    Zhang, Lifu
    Wang, Dadong
    Wu, Taixia
    Tong, Qingxi
    2013 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2013, : 2188 - 2191
  • [48] Absolute Polarization Measurement Using a Vector Light Shift
    Zhu, Kunyan
    Solmeyer, Neal
    Tang, Cheng
    Weiss, David S.
    PHYSICAL REVIEW LETTERS, 2013, 111 (24)
  • [49] Visible Infrared Imaging Radiometer Suite solar diffuser calibration and its challenges using a solar diffuser stability monitor
    Sun, Junqiang
    Wang, Menghua
    APPLIED OPTICS, 2014, 53 (36) : 8571 - 8584
  • [50] Geometric distance measurement using light echo polarization
    Sparks, W. B.