Endovascular procedures under near-real-time magnetic resonance imaging guidance:: An experimental feasibility study

被引:22
|
作者
Dion, YM
El Kadi, HB
Boudoux, C
Gourdon, J
Chakfé, N
Traoré, A
Moisan, C
机构
[1] CHU Quebec, St Francois Assise Hosp, IMRI Unit, Quebec City, PQ G1L 3L5, Canada
[2] Univ Laval, Dept Surg, Quebec City, PQ, Canada
[3] Univ Laval, Dept Engn, Quebec City, PQ, Canada
[4] Univ Laval, Lab Anim Div, Quebec City, PQ, Canada
[5] Hop Univ Strasbourg, Dept Surg, Strasbourg, France
关键词
D O I
10.1067/mva.2000.109208
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: The purpose of this study was to assess the feasibility of insertion of endovascular stents and the precision of an open-field interventional nlagnetic resonance imaging (iMRI) system in an in vivo model, Methods: A feasibility study was undertaken at a university-affiliated hospital. Three male piglets with an average age of 6 months and a weight between 70 and 77 kg and two 3-month-old male piglets that weighed 40 to 44 kg were anesthetized. The five piglets underwent placement of nitinol stents inserted through the right femoral artery under the guidance of a SIGNA-SP 0.5T open-configuration iMRI unit. With a dedicated high-resolution near-real-time MRI sequence, the stent was guided and deployed onto a predefined target. Results: The main outcome measures were the duration of the procedure from the beginning of positioning to the end of deployment of the stent, the final position of the stent in relation to the target on the iMRI screen, and comparison with autopsy findings. Three stents were deployed within the aorta at the level of the renal arteries, and two were deployed within the right iliac artery just below the aortic trifurcation, The average duration of the endovascular deployment was 13 minutes. There was an agreement of 0.6 mm in the position of the stent as observed on iMR images and found at autopsy. When the piglets were sacrificed, the average distance between the stents and the predefined target was 7.8 mm, mostly because of the migration of one stent. Axial views allowed for accurate determination of stent impaction on the vascular wall. Conclusions: This study confirms the feasibility of stent deployment under near-real-time MRI guidance. It also emphasizes some inherent characteristics that hold promise with regard to other conventional techniques: stents and vascular structures are visualized in near-real-time in any desired plane, and the technique is performed without the potential adverse effects of ionizing radiations and iodinated contrast agents.
引用
收藏
页码:1006 / 1014
页数:9
相关论文
共 50 条
  • [21] NEAR-REAL-TIME 3D ULTRASONIC STRAIN IMAGING
    Treece, G.
    Lindop, J.
    Gee, A.
    Prager, R.
    ACOUSTICAL IMAGING, VOL 29, 2008, 29 : 27 - 32
  • [22] Real-time magnetic resonance imaging guidance improves the yield of endomyocardial biopsy
    Toby Rogers
    Kanishka Ratnayaka
    Parag Karmarkar
    William Schenke
    Jonathan R Mazal
    Adrienne E Campbell-Washburn
    Ozgur Kocaturk
    Anthony Z Faranesh
    Robert J Lederman
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [23] Real-time magnetic resonance guidance of interventional electrophysiology procedures with passive catheter visualization and tracking
    Nordbeck, Peter
    Quick, Harald H.
    Ladd, Mark E.
    Ritter, Oliver
    HEART RHYTHM, 2013, 10 (06) : 938 - 939
  • [24] CAN MAGNETIC RESONANCE/ULTRASOUND FUSION IMAGING TECHNOLOGY BE USED FOR REAL TIME IMAGE GUIDANCE DURING FOCAL SURGICAL THERAPY FOR PROSTATE CANCER? A FEASIBILITY STUDY
    Abdul-Muhsin, Haidar
    Kawashima, Akira
    Silva, Alvin
    Stanton, Melissa
    Moshero, Gianni
    Castle, Erik
    Andrews, Paul
    Humphreys, Mitchell
    JOURNAL OF UROLOGY, 2016, 195 (04): : E207 - E207
  • [25] Feasibility of real-time magnetic resonance imaging-guided endomyocardial biopsies: An in-vitro study
    Lossnitzer, Dirk
    Seitz, Sebastian A.
    Krautz, Birgit
    Schnackenburg, Bernhard
    Andre, Florian
    Korosoglou, Grigorios
    Katus, Hugo A.
    Steen, Henning
    WORLD JOURNAL OF CARDIOLOGY, 2015, 7 (07): : 415 - 422
  • [26] Transapical aortic valve replacement using real-time magnetic resonance imaging guidance
    Horvath, Keith
    Guttman, Michael
    Li, Ming
    Lederman, Robert
    Mazilu, Dumitru
    Kocaturk, Ozgur
    Karmarkar, Parag
    Hunt, Timothy
    Kozlov, Shawn
    McVeigh, Elliot
    CIRCULATION, 2006, 114 (18) : 524 - 524
  • [27] A Study on Near-real-time Geometric Correction System of Drones Image
    Jin, Choi Myung
    Young, Kim Tae
    Seob, Lee Min
    Jae, Kim Min
    2018 32ND INTERNATIONAL CONFERENCE ON INFORMATION NETWORKING (ICOIN), 2018, : 70 - 72
  • [28] Dilatation of the pulmonary valve and pulmonary artery branches under real-time magnetic resonance imaging guidance in an animal model
    Rickers, C
    Jerosch-Herold, M
    Zenovich, A
    Mansoor, A
    Wilke, N
    Hu, S
    Kong, H
    EUROPEAN HEART JOURNAL, 2001, 22 : 10 - 10
  • [29] Real-Time Magnetic Resonance Imaging
    Nayak, Krishna S.
    Lim, Yongwan
    Campbell-Washburn, Adrienne E.
    Steeden, Jennifer
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 55 (01) : 81 - 99
  • [30] Feasibility of transperineal prostate biopsy under interventional magnetic resonance guidance
    Cormack, RA
    D'Amico, AV
    Hata, N
    Silverman, S
    Weinstein, M
    Tempany, CM
    UROLOGY, 2000, 56 (04) : 663 - 664