Disposable blood potassium sensors based on screen-printed thick film electrodes

被引:15
|
作者
Xu, Hui [1 ]
Yang, Xiaoxi [2 ]
Wang, You [1 ]
Zheng, Junbao [3 ]
Luo, Zhiyuan [4 ]
Li, Guang [1 ]
机构
[1] Zhejiang Univ, State Key Lab Ind Control Technol, Inst Cyber Syst & Control, Hangzhou 310027, Zhejiang, Peoples R China
[2] Zhejiang Univ, Dept Biomed Engn, Hangzhou 310027, Zhejiang, Peoples R China
[3] Zhejiang Sci Tech Univ, Coll Informat & Elect, Hangzhou 310018, Zhejiang, Peoples R China
[4] Univ London, Comp Learning Res Ctr, Egham TW20 0EX, Surrey, England
基金
国家高技术研究发展计划(863计划);
关键词
thick film; potassium-selective electrode; reference electrode; valinomycin; conducting polymer; poly(3; 4-ethylenedioxythiophene); screen printing; SELECTIVE ELECTRODE; POTENTIOMETRIC SENSORS; POTENTIAL STABILITY; CONDUCTING POLYMERS; MICROELECTRODES;
D O I
10.1088/0957-0233/21/5/055802
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A sensor based on the screen-printing technique for the rapid blood potassium test was developed. The sensor consists of a thick film potassium ion-selective electrode and a reference electrode. Poly(3,4-ethylenedioxythiophene) (PEDOT) doped with poly(styrenesulfonate) (PSS) was screen-printed on carbon electrodes as an internal solid contact layer for both ion-selective and reference electrodes. PVC membranes with and without selective ionphore valinomycin were coated on the PEDOT/PSS layer to form potassium ion-selective and reference electrodes, respectively. The potentiometric response characters were evaluated. The response time of the sensor was 15 s when less than 15 mu L of sample was applied. The sensitivity of the potassium sensor was around 60 mV per decade, while the potentiometric log selectivity coefficients were -3.43 and -3.48 for Na+ and Ca2+, respectively.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] A Simple Method to Tune Up Screen-Printed Carbon Electrodes Applicable to the Design of Disposable Electrochemical Sensors
    Su, Ya-Ling
    Tai, Chun-Yen
    Zen, Jyh-Myng
    ELECTROANALYSIS, 2013, 25 (11) : 2539 - 2546
  • [22] Highly sensitive and disposable screen-printed ionic liquid/graphene based electrochemical sensors
    Kamsong, Wichayaporn
    Primpray, Vitsarut
    Pasakon, Patiya
    Sriprachuabwong, Chakrit
    Pakapongpan, Saithip
    Mensing, Johannes Philipp
    Wisitsoraat, Anurat
    Tuantranont, Adisorn
    Karuwan, Chanpen
    Electrochemistry Communications, 2022, 135
  • [23] Screen-printed electrodes as disposable or reusable optical devices for luminol electrochemiluminescence
    Leca, BD
    Verdier, AM
    Blum, LJ
    SENSORS AND ACTUATORS B-CHEMICAL, 2001, 74 (1-3) : 190 - 193
  • [24] Disposable Miniaturized Screen-Printed pH and Reference Electrodes for Potentiometric Systems
    Musa, Arnaud Emmanuel
    Javier del Campo, Francisco
    Abramova, Natalia
    Asuncion Alonso-Lomillo, Maria
    Dominguez-Renedo, Olga
    Julia Arcos-Martinez, Maria
    Brivio, Monica
    Snakenborg, Detlef
    Geschke, Oliver
    Kutter, Jorg Peter
    ELECTROANALYSIS, 2011, 23 (01) : 115 - 121
  • [25] Highly sensitive and disposable screen-printed ionic liquid/graphene based electrochemical sensors
    Kamsong, Wichayaporn
    Primpray, Vitsarut
    Pasakon, Patiya
    Sriprachuabwong, Chakrit
    Pakapongpan, Saithip
    Mensing, Johannes Philipp
    Wisitsoraat, Anurat
    Tuantranont, Adisorn
    Karuwan, Chanpen
    ELECTROCHEMISTRY COMMUNICATIONS, 2022, 135
  • [26] Detection of ricin in water samples using disposable screen-printed electrodes
    Suresh, S.
    Kumar, Om
    Kolhe, Pawan
    Rao, V. Kameswara
    Sekhar, K.
    DEFENCE SCIENCE JOURNAL, 2007, 57 (06) : 839 - 844
  • [27] Screen-Printed Carbon Electrodes with Porous Copper Film
    Metelka, Radovan
    Vlasakova, Pavlina
    XXXII. MODERNI ELEKTROCHEMICKE METODY, 2012, : 73 - 76
  • [28] Environmental monitoring field tests using screen-printed thick-film sensors based on semiconducting oxides
    Traversa, E
    Sadaoka, Y
    Carotta, MC
    Martinelli, G
    SENSORS AND ACTUATORS B-CHEMICAL, 2000, 65 (1-3) : 181 - 185
  • [29] Screen-printed electrodes covered by mercury film or meniscus
    Josypcuk, Bohdan
    Tvorynska, Sofiia
    ELECTROCHIMICA ACTA, 2025, 513
  • [30] Environmental monitoring field tests using screen-printed thick-film sensors based on semiconducting oxides
    Traversa, E
    Sadaoka, Y
    Carotta, MC
    Martinelli, G
    TECHNICAL DIGEST OF THE SEVENTH INTERNATIONAL MEETING ON CHEMICAL SENSORS, 1998, : 169 - 171