This manuscript presents our initial results and development of a novel hybrid instrument that combines atmospheric pressure ion mobility spectrometry (AP-IMS) with Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS). Our preliminary results obtained from atmospheric pressure mobility separation of peptide mixtures combined with high-resolution FTICR mass analysis are demonstrated. The custom IMS system was constructed in-house and was coupled to the commercial FTICR-MS instrument through a flared inlet capillary interface. Dual-gate ion filtration was adapted to allow concurrent measurement of both mobility and m/z values. The feasibility of mobility separation was demonstrated with baseline separation of the peptides bradykinin and angiotensin II and their measured reduced mobility constants which were consistent with those previously reported. Furthermore, the unique size-to-charge separation mechanism of IMS that allows isomer separation was explored and demonstrated with the partial separation of two isomeric phosphopeptides. We feel the combination of IMS and FTICR-MS holds great potential for accurate mass analysis of mobility-selected ions and these results are the first to demonstrate the feasibility of coupling these two techniques. Copyright (c) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:1115 / 1122
页数:8
相关论文
共 50 条
  • [21] Fourier Transform Ion Cyclotron Resonance Mass Spectrometry at the Cyclotron Frequency
    Nagornov, Konstantin O.
    Kozhinov, Anton N.
    Tsybin, Yury O.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2017, 28 (04) : 768 - 780
  • [22] An external source 7 T Fourier transform ion cyclotron resonance mass spectrometer with electrostatic ion guide
    White, FM
    Marto, JA
    Marshall, AG
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1996, 10 (14) : 1845 - 1849
  • [23] Incorporation of a flared inlet capillary tube on a Fourier transform ion cyclotron resonance mass spectrometer
    Wu, Si
    Zhang, Kai
    Kaiser, Nathan K.
    Bruce, James E.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2006, 17 (06) : 772 - 779
  • [24] Fourier Transform Ion Cyclotron Resonance
    Skriba, Anton
    Houst, Jiri
    Havlicek, Vladimir
    CHEMICKE LISTY, 2020, 114 (02): : 119 - 125
  • [25] Incorporation of a Flared Inlet Capillary Tube on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
    Wu, Si
    Zhang, Kai
    Kaiser, Nathan K.
    Bruce, James E.
    Prior, David C.
    Anderson, Gordon A.
    Journal of the American Society for Mass Spectrometry, 2006, 17 (06): : 772 - 779
  • [26] Quantitation of ion abundances in Fourier transform ion cyclotron resonance mass spectrometry
    Goodner, KL
    Milgram, KE
    Williams, KR
    Watson, CH
    Eyler, JR
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (11) : 1204 - 1212
  • [27] Fourier transform ion cyclotron resonance mass spectrometry: A primer
    Marshall, AG
    Hendrickson, CL
    Jackson, GS
    MASS SPECTROMETRY REVIEWS, 1998, 17 (01) : 1 - 35
  • [28] Fourier transform ion cyclotron resonance mass spectrometry - Preface
    Marshall, AG
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1996, 157 : R9 - R11
  • [29] Progress in Fourier transform ion cyclotron resonance mass spectroscopy
    Wang, W
    Cai, WS
    Shao, XG
    PROGRESS IN CHEMISTRY, 2005, 17 (02) : 336 - 342
  • [30] Sidebands in Fourier transform ion cyclotron resonance mass spectra
    Miladinovic, Sasa M.
    Kozhinov, Anton N.
    Tsybin, Oleg Yu.
    Tsybin, Yury O.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2012, 325 : 10 - 18