LC-HRMS Metabolomics for Untargeted Diagnostic Screening in Clinical Laboratories: A Feasibility Study

被引:9
|
作者
Rochat, Bertrand [1 ]
Mohamed, Rayane [2 ]
Sottas, Pierre-Edouard [3 ]
机构
[1] Univ Lausanne, CIG, Prot Anal Facil, CH-1015 Lausanne, Switzerland
[2] CHU Vaudois, Dept Format Rech, CH-1011 Lausanne, Switzerland
[3] Biokaizen Lab SA, CH-1870 Monthey, Switzerland
来源
METABOLITES | 2018年 / 8卷 / 02期
关键词
clinical/biomedical analysis; diagnostic; forensic/toxicology; high resolution mass spectrometry; liquid chromatography; metabolomics; screening; untargeted; RESOLUTION MASS-SPECTROMETRY; QUANTITATIVE PERFORMANCE; INBORN-ERRORS; ILLICIT DRUGS; MS; ORBITRAP; TYRANNY; FUTURE;
D O I
10.3390/metabo8020039
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Today's high-resolution mass spectrometers (HRMS) allow bioanalysts to perform untargeted/global determinations that can reveal unexpected compounds or concentrations in a patient's sample. This could be performed for preliminary diagnosis attempts when usual diagnostic processes and targeted determinations fail. We have evaluated an untargeted diagnostic screening (UDS) procedure. UDS is a metabolome analysis that compares one sample (e.g., a patient) with control samples (a healthy population). Using liquid chromatography (LC)-HRMS full-scan analysis of human serum extracts and unsupervised data treatment, we have compared individual samples that were spiked with one xenobiotic or a higher level of one endogenous compound with control samples. After the use of different filters that drastically reduced the number of metabolites detected, the spiked compound was eventually revealed in each test sample and ranked. The proposed UDS procedure appears feasible and reliable to reveal unexpected xenobiotics (toxicology) or higher concentrations of endogenous metabolites. HRMS-based untargeted approaches could be useful as preliminary diagnostic screening when canonical processes do not reveal disease etiology nor establish a clear diagnosis and could reduce misdiagnosis. On the other hand, the risk of overdiagnosis of this approach should be reduced with mandatory biomedical interpretation of the patient's UDS results and with confirmatory targeted and quantitative determinations.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Ammonium Fluoride as Suitable Additive for HILIC-Based LC-HRMS Metabolomics
    Narduzzi, Luca
    Royer, Anne-Lise
    Bichon, Emmanuelle
    Guitton, Yann
    Buisson, Corinne
    Le Bizec, Bruno
    Dervilly-Pinel, Gaud
    METABOLITES, 2019, 9 (12)
  • [32] Towards Unbiased Evaluation of Ionization Performance in LC-HRMS Metabolomics Method Development
    Jaeger, Carsten
    Lisec, Jan
    METABOLITES, 2022, 12 (05)
  • [33] Linking MS1 and MS2 signals in positive and negative modes of LC-HRMS in untargeted metabolomics using the ROIMCR approach
    Yamamoto, Flavia Yoshie
    Perez-Lopez, Carlos
    Lopez-Antia, Ana
    Lacorte, Silvia
    Abessa, Denis Moledo de Souza
    Tauler, Roma
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (25) : 6213 - 6225
  • [34] Time and dose-dependent impairment of liver metabolism in Gasterosteus aculeatus following exposure to diclofenac (DCF) highlighted by LC-HRMS untargeted metabolomics
    Lebeau-Roche, Emmanuelle
    Daniele, Gaelle
    Fildier, Aurelie
    Bonnefoy, Christelle
    Turies, Cyril
    Bado-Nilles, Anne
    Porcher, Jean-Marc
    Dedourge-Geffard, Odile
    Vulliet, Emmanuelle
    Geffard, Alain
    SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 858
  • [35] Exploration of chemical components correlated with pharmacology of EHYT based on a LC-HRMS metabolomics approach
    Ha, In Jin
    Kim, Eunok
    Kim, Kyuseok
    FASEB JOURNAL, 2017, 31
  • [36] Linking MS1 and MS2 signals in positive and negative modes of LC-HRMS in untargeted metabolomics using the ROIMCR approach
    Flávia Yoshie Yamamoto
    Carlos Pérez-López
    Ana Lopez-Antia
    Silvia Lacorte
    Denis Moledo de Souza Abessa
    Romà Tauler
    Analytical and Bioanalytical Chemistry, 2023, 415 : 6213 - 6225
  • [37] Development of LC-HRMS untargeted analysis methods for neurological extracellular vesicles into environmental exposure science
    Hospital, C. Duarte
    Jaffar, C.
    Re, D.
    Sing, R.
    Miller, G. W.
    TOXICOLOGY LETTERS, 2024, 399 : S323 - S323
  • [38] Validation of two LC-HRMS methods for large-scale untargeted metabolomics of serum samples: Strategy to establish method fitness-for-purpose
    Grijseels, Sietske
    Vasskog, Terje
    Heinsvig, Pia J.
    Myhre, Torbjorn N.
    Hansen, Terkel
    Mardal, Marie
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1732
  • [39] Validation of a dual LC–HRMS platform for clinical metabolic diagnosis in serum, bridging quantitative analysis and untargeted metabolomics
    Ilya Gertsman
    Jon A. Gangoiti
    Bruce A. Barshop
    Metabolomics, 2014, 10 : 312 - 323
  • [40] Missing value imputation and data cleaning in untargeted food chemical safety assessment by LC-HRMS
    Delaporte, Gregoire
    Cladiere, Mathieu
    Camel, Valerie
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2019, 188 : 54 - 62