The effect of cataract on accumap multifocal objective perimetry

被引:5
|
作者
Whitehouse, GM [1 ]
机构
[1] Forster Eye Surg, Forster 2428, Australia
关键词
D O I
10.1016/S0002-9394(02)02276-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine the effect of visually significant cataract on Accumap multifocal objective perimetry. DESIGN: Interventional case series. METHODS: Fifteen eyes of 15 adult patients who underwent standard outpatient phacoemulsification cataract surgery with posterior chamber intraocular lens insertion with subsequent improvement of best-corrected visual acuity underwent Accumap testing before and after cataract extraction. Patients had no other ophthalmic disease or other conditions that may have affected visual evoked potentials. Results were analyzed statistically. RESULTS: Visually significant cataract was associated with a statistically significant reduction of mean Accumap amplitudes within the central 107 degrees (zone 1, P = .002; zone 2, P = .003; zone 3, P = .001) but did not affect the outer two zones (zone 4, P = .074; zone 5, P = .931). CONCLUSIONS: Accumap visual fields may be affected by visually significant cataract. Multifocal objective perimetry defects in the central 10 degrees should be interpreted with caution in patients with cataract. (C) 2003 by Elsevier Inc. All rights reserved.
引用
收藏
页码:209 / 212
页数:4
相关论文
共 50 条
  • [31] Comparing multifocal pupillographic objective perimetry (mfPOP) and multifocal visual evoked potentials (mfVEP) in retinal diseases
    Faran Sabeti
    Andrew C. James
    Corinne F. Carle
    Rohan W. Essex
    Andrew Bell
    Ted Maddess
    Scientific Reports, 7
  • [32] Comparing multifocal pupillographic objective perimetry (mfPOP) and multifocal visual evoked potentials (mfVEP) in retinal diseases
    Sabeti, Faran
    James, Andrew C.
    Carle, Corinne F.
    Essex, Rohan W.
    Bell, Andrew
    Maddess, Ted
    SCIENTIFIC REPORTS, 2017, 7
  • [33] The effect of cataract on Frequency doubling perimetry.
    Byles, DS
    Chua, C
    Rahman, R
    Constable, P
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S149 - S149
  • [34] Effect of cataract extraction on frequency doubling technology perimetry
    Kook, MS
    Yang, SJ
    Kim, S
    Chung, J
    Kim, ST
    Tchah, H
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 138 (01) : 85 - 90
  • [35] Effect of cataract extraction on SITA perimetry in patients with glaucoma
    Siddiqui, M. A. Rehman
    Khairy, Hany A.
    Azuara-Blanco, Augusto
    JOURNAL OF GLAUCOMA, 2007, 16 (02) : 205 - 208
  • [36] PERIMETRY IN CATARACT PATIENTS
    RADIUS, RL
    ARCHIVES OF OPHTHALMOLOGY, 1978, 96 (09) : 1574 - 1579
  • [37] Effect of cataract on frequency doubling perimetry in the screening mode
    Casson, RJ
    James, B
    JOURNAL OF GLAUCOMA, 2006, 15 (01) : 23 - 25
  • [38] Effect of cataract extraction on the results of automated perimetry in glaucoma
    Smith, SD
    Katz, J
    Quigley, HA
    ARCHIVES OF OPHTHALMOLOGY, 1997, 115 (12) : 1515 - 1519
  • [39] High- versus low-density multifocal pupillographic objective perimetry in glaucoma
    Maddess, Ted
    Essex, Rohan W.
    Kolic, Maria
    Carle, Corinne F.
    James, Andrew C.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 41 (02): : 140 - 147
  • [40] Clinical application of objective perimetry using multifocal visual evoked potentials in glaucoma practice
    Graham, SL
    Klistorner, AI
    Goldberg, I
    ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (06) : 729 - 739