Relevance of the prostate-specific antigen (PSA) nanotest compared to the classical PSA test in the organized mass screening of prostate cancer

被引:2
|
作者
Azzouzi, Abdel-Rahmene
Larre, Stephane
Cormier, Luc
Roupret, Morgan
Valeri, Antoine
Mangin, Philippe
Berthon, Philippe
Villette, Jean-Marie
Fiet, Jean
Cussenot, Olivier
机构
[1] CHU Angers, Dept Urol, F-49933 Angers, France
[2] CeRePP, UPRES, UFR, Biomed St Peres, Paris, France
[3] CHU Nancy Brabois, Dept Urol, Vandoeuvre Les Nancy, France
[4] CHU Cavale Blanche, Brest, France
[5] UroGene, Evry, France
[6] Hop St Louis, Dept Hormonol, Paris, France
[7] Inst Univ France, Paris, France
关键词
PSA; mass screening; prostate cancer; population surveillance;
D O I
10.1111/j.1464-410X.2006.06701.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE: To assess the reliability of a new measurement of prostate-specific antigen (PSA) using a blotting-paper assay (nanotest) compared to the standard PSA immunoassay. SUBJECTS AND METHODS: The PSA level was measured in 205 men volunteers (median age 70 years, range 41-75) using a nanotest and a standard PSA immunoassay, collected at the same time; 30 mu L of capillary blood placed on to a blotting paper were collected for the nanotest and sent by mail to the same laboratory for the two assays. The results were compared statistically using the Spearman test, the intraclass correlation coefficient and the Bland-Altman test. RESULTS: The nanotest threshold for an abnormal PSA level was 78 pg/mL, which corresponded to a standard PSA value of 3 ng/mL, with a sensitivity of 100%. There was a significant correlation (r = 0.98, Spearman test; P < 0.001) between the nanotest and the standard PSA assay. The intraclass correlation coefficient was 0.87. The Bland-Altman test showed a good agreement between the nanotest and the standard PSA assay, but there was an increasing proportional difference with increasing PSA value. CONCLUSION: There was a very high correlation between the nanotest and the standard PSA assay, especially for standard PSA levels of < 5 ng/mL. Economic and clinical studies are indicated to confirm the utility of the nanotest in organized mass screening of prostate cancer.
引用
收藏
页码:762 / 764
页数:3
相关论文
共 50 条
  • [31] Prostate-specific antigen (PSA) kinetics in untreated, localized prostate cancer: PSA velocity vs PSA doubling time
    Ng, Michael K.
    Van As, Nicholas
    Thomas, Karen
    Woode-Amissah, Ruth
    Horwich, Alan
    Huddart, Robert
    Khoo, Vincent
    Thompson, Alan
    Dearnaley, David
    Parker, Chris
    BJU INTERNATIONAL, 2009, 103 (07) : 872 - 876
  • [32] Prostate-specific Antigen (PSA) Screening and a Lifesaving Cardiac Transplant
    Kanabolo, Diboro
    True, Lawrence
    Vakar-Lopez, Funda
    Tretiakova, Maria
    Nyame, Yaw A.
    UROLOGY, 2022, 168 : E1 - E2
  • [33] Serum Prostate-Specific Antigen (PSA) Concentration, PSA Mass, and Obesity A Mathematical Analysis
    Vollmer, Robin T.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2018, 149 (03) : 262 - 266
  • [34] Clinical evaluation of free PSA total PSA (prostate-specific antigen) ratio in the diagnosis of prostate cancer
    Filella, X
    Alcover, J
    Molina, R
    Rodriguez, A
    Carretero, P
    Ballesta, AM
    EUROPEAN JOURNAL OF CANCER, 1997, 33 (08) : 1226 - 1229
  • [35] Value of prostate-specific antigen (PSA) mass ratio in the detection of prostate cancer in men with PSA levels of ≤10 ng/mL
    Hong, Sung Kyu
    Oh, Jong Jin
    Byun, Seok-Soo
    Hwang, Sung Il
    Choo, Min Soo
    Lee, Sang Eun
    BJU INTERNATIONAL, 2012, 110 (2B) : E81 - E85
  • [36] Assessment of Prostate-Specific Antigen (PSA) Kinetics in Prediction of Prostate Cancer on Prostate Biopsy
    Shinmei, S.
    Inoue, S.
    Ohkuchi, T.
    Yasukawa, A.
    UROLOGY, 2012, 80 (03) : S282 - S282
  • [37] Prostate-specific Antigen (PSA) Density and Free to Total PSA Ratio in Diagnosing Prostate Cancer with Prostate-Specific Antigen Levels of 4.0 ng/ml or Less
    Liu, Xin
    Tang, Jie
    Fei, Xiang
    Li, Qiu-Yang
    IRANIAN JOURNAL OF PUBLIC HEALTH, 2015, 44 (11) : 1466 - 1472
  • [38] A UNIVERSAL CALIBRATOR FOR PROSTATE-SPECIFIC ANTIGEN (PSA)
    PRESTIGIACOMO, AF
    CHEN, Z
    STAMEY, TA
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1995, 55 : 57 - 59
  • [39] Substrate specificity of prostate-specific antigen (PSA)
    Coombs, GS
    Bergstrom, RC
    Pellequer, JL
    Baker, SI
    Navre, M
    Smith, MM
    Tainer, JA
    Madison, EL
    Corey, DR
    CHEMISTRY & BIOLOGY, 1998, 5 (09): : 475 - 488
  • [40] Antiangiogenic properties of prostate-specific antigen (PSA)
    Mattsson, Johanna M.
    Laakkonen, Pirjo
    Stenman, Ulf-Hakan
    Koistinen, Hannu
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2009, 69 (04): : 447 - 451