Interpretation of the relation between residual charge and water trees in XLPE cables

被引:0
|
作者
Hirai, N [1 ]
Ohki, Y [1 ]
Takeda, T [1 ]
Okamoto, T [1 ]
机构
[1] Waseda Univ, Dept Elect Elect & Comp Engn, Tokyo 1698555, Japan
关键词
XLPE cable; water tree; degradation; residual charge; insulation diagnosis;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Crosslinked polyethylene (XLPE) insulated cables working in water are known to be easily degraded by forming water trees. This is one of the most serious concerns among users of XLPE cables. The possibility whether measurement of residual charge is usable as a tool to detect water trees in XLPE is discussed. Two types of samples were used; one is an XLPE cable with water trees and the other is an XLPE sheet with water trees grown by ac voltage application, The sheet sample was used since we thought that we could easily check the growth of water trees and could also use a generator of a small capacity, which enabled precise experiments. The results obtained are summarized as follows. (1) Residual charge was not measured in the sheet sample because of its small electrode area. (2) Residual charge was detected in the cable sample. (3) A clear frequency dependence of the residual charge was not observed. A model of the residual charge measurement is proposed, where the charges accumulated in a water tree are oscillated by ac electric field and are diffused through the water tree path with a high conductivity. The frequency dependence of the residual charge is discussed by dividing it into the contribution of the electric field distribution, that of the detrapping process, and that of the carrier transportation process into the electrode. As a result, it is confirmed that the weak frequency dependence of the residual charge is reasonable.
引用
收藏
页码:1094 / 1099
页数:6
相关论文
共 50 条
  • [1] Study on Short Time Charge Behavior in Pulsed Residual Charge Method for Water Tree Diagnostics of XLPE Cables
    Futami, Hiroyuki
    Ra, Nhet
    Kawashima, Tomohiro
    Murakami, Yoshinobu
    Hozumi, Naohiro
    Kurihara, Takashi
    Okamoto, Tatsuki
    Miyajima, Kazuhisa
    Uchida, Katsumi
    2017 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM), VOLS 1 & 2, 2017, : 559 - 562
  • [2] Measurement of Residual Charge using Pulse Voltages for Water Tree Degraded XLPE Cables Diagnosis
    Kurihara, Takashi
    Okamoto, Tatsuki
    Kim, Myong Hwan
    Hozumi, Naohiro
    Tsuji, Taizo
    Uchida, Katsumi
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (01) : 321 - 330
  • [3] Diagnostic testing of MV XLPE cables with low density of water trees
    Hvidsten, S
    Benjaminsen, JT
    CONFERENCE RECORD OF THE 2002 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2002, : 108 - 111
  • [4] THE VOLTAGE BREAKDOWN CHARACTERISTICS OF MINIATURE XLPE CABLES CONTAINING WATER TREES
    BULINSKI, A
    DENSLEY, RJ
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1981, 16 (04): : 319 - 326
  • [5] IMPULSE STRENGTH OF NATURALLY AGED XLPE-CABLES CONTAINING WATER TREES
    DENSLEY, RJ
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1978, 13 (05): : 389 - 391
  • [6] Relationship between Residual Charge Signals and AC Breakdown Voltages of Removed 6.6 kV XLPE Cables Using Residual Charge Detection Method with Pulse Voltages
    Kurihara, Takashi
    Okamoto, Tatsuki
    Miyajima, Kazuhisa
    Uchida, Katsumi
    Kim, Myong Hwan
    Hozumi, Naohiro
    PROCEEDINGS OF 2014 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM 2014), 2014, : 257 - 260
  • [7] Fundamental study on diagnostic method of water tree degraded XLPE cables using residual charge detection with pulse voltages
    Kurihara, Takashi
    Okamoto, Tatsuki
    Kim, Myong Hwan
    Hozumi, Naohiro
    Tsuji, Taizo
    Miyajima, Kazuhisa
    Uchida, Katsumi
    IEEJ Transactions on Power and Energy, 2014, 134 (08) : 648 - 658
  • [8] Detection of water trees in medium voltage XLPE cables by return voltage measurements
    Jonuz, B
    Morshuis, PHF
    van Breen, HJ
    Pellis, J
    Smit, JJ
    2000 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS. I & II, 2000, : 355 - 358
  • [9] Fundamental Study on Residual Charge Detection with Pulse Voltages as Diagnostic Method of Water Tree-Degraded XLPE Cables
    Kurihara, Takashi
    Okamoto, Tatsuki
    Tsuji, Taizo
    Uchida, Katsumi
    Kim, Myong Hwan
    Hozumi, Naohiro
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 84 - 87
  • [10] Initiation of Vented Water Trees from the Conductor Screen of MV XLPE Insulated Cables
    Faremo, Hallvard
    Selsjord, Mildrid
    Hvidsten, Sverre
    Bengtsson, Karl Magnus
    Ryen, Arve
    CONFERENCE RECORD OF THE 2012 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2012, : 386 - 390