Iatrogenic Tracheal Rupture during Intubation with a Double-Lumen Tube

被引:8
|
作者
Tezel, C. [1 ]
Okur, E. [1 ]
Baysungur, V. [1 ]
机构
[1] Sureyyapasa Chest Dis & Thorac Surg Teaching Hosp, Dept Thorac Surg, TR-34744 Istanbul, Turkey
来源
THORACIC AND CARDIOVASCULAR SURGEON | 2010年 / 58卷 / 01期
关键词
Thoracic surgery; tracheal rupture; double-lumen tube; MANAGEMENT; INJURY;
D O I
10.1055/s-0029-1186150
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Iatrogenic tracheal rupture after intubation with a double-lumen endotracheal tube is rare. An endobronchial tube positioning guide stylet, which is generally used during intubations with a double-lumen tube, may tear the trachea. A 76-year-old patient with right upper lobe carcinoma was scheduled for video-thoracoscopic lobectomy. Mediastinal lymph node dissection was performed after a right upper lobectomy. When the mediastinal pleura in the right paratracheal region were opened, a tracheal cuff was noticed in the mediastinum. The tear in the membranous part of the trachea was repaired. Use of stylets during intubation may cause tracheal injury. To prevent such an injury, the stylet should be withdrawn after the tip of the tube has passed through the vocal cords.
引用
收藏
页码:54 / U4
页数:3
相关论文
共 50 条
  • [21] AIRWAY RUPTURE WITH A DISPOSABLE DOUBLE-LUMEN TUBE
    BRODSKY, JB
    SHULMAN, MS
    MARK, JBD
    ANESTHESIOLOGY, 1986, 64 (03) : 415 - 415
  • [22] 180° rotation of double-lumen endobronchial tube during intubation Reply
    Bahk, J. -H.
    Sea, J. -H.
    BRITISH JOURNAL OF ANAESTHESIA, 2014, 112 (05) : 938 - 938
  • [23] A simple method to protect the tracheal cuff during double-lumen endotracheal intubation
    Yao, Weifeng
    Zhu, Wenxiu
    Zhang, Yihan
    Guan, Jianqiang
    JOURNAL OF CLINICAL ANESTHESIA, 2021, 70
  • [24] The Airway Scope for difficult double-lumen tube intubation
    Mmed, K. H. Poon
    Liu, Eugene H. C.
    JOURNAL OF CLINICAL ANESTHESIA, 2008, 20 (04) : 319 - 319
  • [25] Bronchial rupture by a double-lumen endobronchial tube during staging thoracoscopy
    Gilbert, TB
    Goodsell, CW
    Krasna, MJ
    ANESTHESIA AND ANALGESIA, 1999, 88 (06): : 1252 - 1253
  • [26] Tracheal tear caused by extubation of a double-lumen tube
    Benumof, JL
    Wu, D
    ANESTHESIOLOGY, 2002, 97 (04) : 1007 - 1008
  • [27] Double-lumen tube tracheal intubation in a manikin model using the VivaSight Double Lumen: a randomized controlled comparison with the Macintosh laryngoscope
    Szarpak, Lukasz
    Kurowski, Andrzej
    Zasko, Piotr
    Karczewska, Katarzyna
    Czyzewski, Lukasz
    Bogdanski, Lukasz
    Adamczyk, Piotr
    Truszewski, Zenon
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (01): : 103 - 104
  • [28] Efficacy of bronchofiberscope double-lumen tracheal tube intubation combined with McGRATH MAC for difficult airway
    Imajo, Yukihiro
    Komasawa, Nobuyasu
    Minami, Toshiaki
    JOURNAL OF CLINICAL ANESTHESIA, 2015, 27 (04) : 362 - 362
  • [29] A randomized comparison between the VivaSight double-lumen tube and standard double-lumen tube intubation in thoracic surgery patients
    Palaczynski, Piotr
    Misiolek, Hanna
    Bialka, Szymon
    Owczarek, Aleksander J.
    Gola, Wojciech
    Szarpak, Lukasz
    Smereka, Jacek
    JOURNAL OF THORACIC DISEASE, 2022, : 3903 - 3914
  • [30] Tracheal diameter predicts double-lumen tube size: A method for selecting left double-lumen tubes
    Brodsky, JB
    Macario, A
    Mark, JBD
    ANESTHESIA AND ANALGESIA, 1996, 82 (04): : 861 - 864