Optimization of conformal thoracic radiotherapy using cone-beam CT imaging for treatment verification

被引:35
|
作者
Sidhu, K
Ford, EC
Spirou, S
Yorke, E
Chang, JW
Mueller, K
Todor, D
Rosenzweig, K
Mageras, G
Chui, C
Ling, CC
Amols, H
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Radiat Oncol, New York, NY 10021 USA
[3] SUNY Stony Brook, Dept Comp Sci, Stony Brook, NY 11794 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2003年 / 55卷 / 03期
关键词
megavoltage CT; cone-beam CT; treatment verification; radiotherapy planning; electronic portal imaging device;
D O I
10.1016/S0360-3016(02)04152-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Megavoltage cone-beam computed tomography (MVCBCT) has been proposed for treatment verification in conformal radiotherapy. However, the doses required for such imaging may compromise the quality of the delivered dose distribution. The present paper explores the effect of cone-beam imaging on dose homogeneity and critical organ dose and the use of our new tool, adapted intensity-modulated radiation therapy (AIMRT). Methods and Materials: Three types of treatment plans were devised (3D-CRT [three-dimensional conformal radiotherapy], IMRT [intensity-modulated radiotherapy], and AIMRT) based on 4 patients with thoracic malignancies. MVCBCT fields were then integrated into the plans. The MVCBCT technique used 21 imaging portals at 10degrees intervals. The MVCBCT apertures were shaped to conform to the planning target volume with a 6-mm margin. In a second set of plans, the field size was expanded by a further 2 cm. The unoptimized MVCBCT dose distribution was incorporated into the IMRT plan using AIMRT. Results: Normal-tissue complication probability with MVCBCT is acceptable for all plans at the 66.6 Gy level, but exceeds tolerance for both 3D-CRT alone and 3D-CRT with MVCBCT at higher doses. In contrast, the use of AIMRT planning with MVCBCT allowed safe dose escalation to 85 Gy. Expanding the MVCBCT aperture provided better anatomic visibility with an acceptable lung dose. The results using IMRT with MVCBCT fell between the values measured for 3D-CRT and AIMRT with MVCBCT. Conclusion: The present study is the first to demonstrate that MVCBCT can be incorporated into 3D-CRT and IMRT planning with minimal effect on planning target volume homogeneity and dose to critical structures. This paves the way for highly conformal radiotherapy at greater doses delivered with increased confidence and safety. (C) 2003 Elsevier Science Inc.
引用
收藏
页码:757 / 767
页数:11
相关论文
共 50 条
  • [21] The use of cone-beam CT for treatment and plan verification in head and neck cancer
    Dirix, P.
    Nuyts, S.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S70 - S70
  • [22] CORRECTION STRATEGIES FOR CONE-BEAM CT GUIDED RADIOTHERAPY
    Remeijer, P.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S141 - S142
  • [23] Clinical implementation of cone-beam CT guided radiotherapy
    van Herk, M
    Jaffray, D
    Remeijer, P
    Sonke, JJ
    Lebesque, JV
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S17 - S17
  • [24] Verification of Cone-Beam CT-based Treatment Plans on the True Beam Linear Accelerator
    Loewenich, K. F.
    Streller, T.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 : 83 - 83
  • [25] Imaging adjustment with dosimetric verification of cone-beam CT in head and neck cancer patient
    Hu, C.
    Wu, J.
    Chao, H.
    Wang, C.
    Tsai, C.
    Cheng, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S603 - S604
  • [26] Image Quality Optimization and Soft Tissue Visualization in Cone-Beam CT Imaging
    Castonguay-Henri, Aude
    Matenine, Dmitri
    Schmittbuhl, Matthieu
    de Guise, Jacques A.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1, 2019, 68 (01): : 283 - 288
  • [27] Design and Optimization of a Dedicated Cone-Beam CT System for Musculoskeletal Extremities Imaging
    Zbijewski, W.
    De Jean, P.
    Prakash, P.
    Ding, Y.
    Stayman, J. W.
    Packard, N.
    Senn, R.
    Yang, D.
    Yorkston, J.
    Machado, A.
    Carrino, J. A.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [28] Cone-beam CT with megavoltage beams and an amorphous silicon electronic portal imaging device: Potential for verification of radiotherapy of lung cancer
    Ford, EC
    Chang, J
    Mueller, K
    Sidhu, K
    Todor, D
    Mageras, G
    Yorke, E
    Ling, CC
    Amols, H
    MEDICAL PHYSICS, 2002, 29 (12) : 2913 - 2924
  • [29] Positioning accuracy for lung stereotactic body radiotherapy patients determined by on-treatment cone-beam CT imaging
    Richmond, N. D.
    Pilling, K. E.
    Peedell, C.
    Shakespeare, D.
    Walker, C. P.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1014): : 819 - 823
  • [30] Density calibrated cone-beam CT as a tool for adaptive radiotherapy
    Nyeng, T. B.
    Holm, A. I.
    Moller, D. S.
    Assenholt, M. S.
    Hansen, R.
    Nyvang, L.
    Ravkilde, T.
    Thomsen, M. S.
    Hoffmann, L.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1292 - S1294