On Feasibility of Near-Infrared Spectroscopy for Noninvasive Blood Glucose Measurements

被引:1
|
作者
Vural, N. Mert [1 ]
Yoleri, Yigit [2 ]
Torun, Hamdi [3 ]
机构
[1] Bilkent Univ, Ankara, Turkey
[2] Univ Calif San Diego, La Jolla, CA 92093 USA
[3] Northumbria Univ, Newcastle Upon Tyne, Tyne & Wear, England
关键词
Near Infrared Spectroscopy; noninvasive measurement; WATER;
D O I
10.1117/12.2503852
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Non-invasive blood glucose measurement has long been desired since the invasive methods are not suitable to perform continuous monitoring. Near Infrared Spectroscopy is one of the most popular methods used in studies; however, despite more than 20 years of research, a practical and reliable noninvasive NIR glucose sensor is yet to be developed. In this study, we investigated the feasibility of NIRS towards the detection of glucose concentration. Although we can obtain adequate sensitivity, our measurements suffer from poor selectivity due to the fact that we can only detect the impurity level of water by NIRS due to strong water absorbance.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Monte Carlo simulation-based thinning and calculating method for noninvasive blood glucose sensing by near-infrared spectroscopy
    Ma, Congcong
    Qin, Jia
    Zhang, Qi
    Lu, Junsheng
    Xu, Kexin
    Jiang, Jingying
    JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2017, 10 (02)
  • [42] Near-infrared reflectance spectroscopy for noninvasive monitoring of metabolites
    Heise, HM
    Bittner, A
    Marbach, R
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2000, 38 (02) : 137 - 145
  • [43] NEAR-INFRARED SPECTROSCOPY - NONINVASIVE MONITORING OF CEREBRAL HEMODYNAMICS
    FAHNENSTICH, H
    KLINISCHE PADIATRIE, 1993, 205 (06): : 398 - 403
  • [44] Noninvasive Monitoring of Placental Oxygenation by Near-Infrared Spectroscopy
    Kakogawa, Jun
    Sumimoto, Kazuhiro
    Kawamura, Takakazu
    Minoura, Shigeki
    Kanayama, Naohiro
    AMERICAN JOURNAL OF PERINATOLOGY, 2010, 27 (06) : 463 - 468
  • [45] Application of Partial Robust M-Regression in Noninvasive Measurement of Human Blood Glucose Concentration with Near-Infrared Spectroscopy
    Li Qing-bo
    Yan Hou-lai
    Li Li-na
    Wu Jin-guang
    Zhang Guang-jun
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30 (08) : 2115 - 2119
  • [46] Noninvasive Human Triglyceride Detecting with Near-Infrared Spectroscopy
    Yuan Jing-ze
    Lu Qi-peng
    Wu Chun-yang
    Ding Hai-quan
    Gao Hong-zhi
    Li Wan-xia
    Wang Yang
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38 (01) : 42 - 48
  • [47] Noninvasive blood glucose sensing by near-infrared spectroscopy based on PLSR combines SAE deep neural network approach
    Han, Guang
    Chen, Siqi
    Wang, Xiaoyan
    Wang, Jinhai
    Wang, Huiquan
    Zhao, Zhe
    INFRARED PHYSICS & TECHNOLOGY, 2021, 113
  • [48] Noninvasive Blood Glucose Monitoring Systems Using Near-Infrared Technology-A Review
    Hina, Aminah
    Saadeh, Wala
    SENSORS, 2022, 22 (13)
  • [49] Noninvasive blood glucose measurement system based on three wavelengths in near-infrared region
    Chen, Yaqin
    Bai, Ge
    Xiao, Jun
    Wang, Long
    Luo, Qingming
    FIFTH INTERNATIONAL CONFERENCE ON PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE, PTS 1 AND 2, 2007, 6534
  • [50] New methodology to obtain a calibration model for noninvasive near-infrared blood glucose monitoring
    Maruo, K
    Oota, T
    Tsurugi, M
    Nakagawa, T
    Arimoto, H
    Tamura, M
    Ozaki, Y
    Yamada, Y
    APPLIED SPECTROSCOPY, 2006, 60 (04) : 441 - 449