On Feasibility of Near-Infrared Spectroscopy for Noninvasive Blood Glucose Measurements

被引:1
|
作者
Vural, N. Mert [1 ]
Yoleri, Yigit [2 ]
Torun, Hamdi [3 ]
机构
[1] Bilkent Univ, Ankara, Turkey
[2] Univ Calif San Diego, La Jolla, CA 92093 USA
[3] Northumbria Univ, Newcastle Upon Tyne, Tyne & Wear, England
关键词
Near Infrared Spectroscopy; noninvasive measurement; WATER;
D O I
10.1117/12.2503852
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Non-invasive blood glucose measurement has long been desired since the invasive methods are not suitable to perform continuous monitoring. Near Infrared Spectroscopy is one of the most popular methods used in studies; however, despite more than 20 years of research, a practical and reliable noninvasive NIR glucose sensor is yet to be developed. In this study, we investigated the feasibility of NIRS towards the detection of glucose concentration. Although we can obtain adequate sensitivity, our measurements suffer from poor selectivity due to the fact that we can only detect the impurity level of water by NIRS due to strong water absorbance.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] New advancement in noninvasive measurement of blood glucose by near-infrared spectroscopy
    Li, QB
    Wang, Y
    Xu, KX
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS: DIAGNOSTICS AND TREATMENT, 2002, 4916 : 457 - 464
  • [2] NONINVASIVE BLOOD-GLUCOSE SENSORS BASED ON NEAR-INFRARED SPECTROSCOPY
    HEISE, HM
    MARBACH, R
    KOSCHINSKY, T
    GRIES, FA
    ARTIFICIAL ORGANS, 1994, 18 (06) : 439 - 447
  • [3] Noninvasive Blood Glucose Analysis Based on Near-Infrared Reflectance Spectroscopy
    Lu Xiao-feng
    Zhang Ting-lin
    Xiao Feng
    Li Guang
    Wang You
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36 (07) : 2312 - 2317
  • [4] Feasibility of measuring blood glucose concentration by near-infrared Raman spectroscopy
    Berger, AJ
    Itzkan, I
    Feld, MS
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 1997, 53 (02) : 287 - 292
  • [5] Near-Infrared Spectroscopy for Noninvasive Measurement of Blood Glucose: Problems, Progress, Tasks
    K. V. Pozhar
    M. O. Mikhailov
    E. L. Litinskaia
    E. A. Polyakova
    Biomedical Engineering, 2022, 56 : 64 - 68
  • [6] Near-Infrared Spectroscopy for Noninvasive Measurement of Blood Glucose: Problems, Progress, Tasks
    Pozhar, K., V
    Mikhailov, M. O.
    Litinskaia, E. L.
    Polyakova, E. A.
    BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA, 2022, 56 (01): : 64 - 68
  • [7] Noninvasive blood glucose sensing with near-infrared spectroscopy based on interstitial fluid
    Lu, Q. (luqipeng@126.com), 1600, Chinese Optical Society (33):
  • [8] Noninvasive Blood Glucose Measurements by Means of Near Infrared Spectroscopy: State of the Art
    Paez Roa, Arbey Alexis
    Villamizar Mejia, Rodolfo
    UIS INGENIERIAS, 2012, 11 (01): : 21 - 33
  • [9] Feasibility of Noninvasive Near-Infrared Spectroscopy to Diagnose Detrusor Overactivity
    Farag, Fawzy F.
    Martens, Frank M.
    Feitz, Wout F.
    Heesakkers, John P.
    UROLOGIA INTERNATIONALIS, 2011, 87 (03) : 330 - 335
  • [10] Principal Component Analysis and Near-Infrared Spectroscopy as Noninvasive Blood Glucose Assay Methods
    Barati, Hadi
    Madani, Arian Mousavi
    Shadzinavaz, Sorena
    Fardmanesh, Mehdi
    APPLIED SPECTROSCOPY, 2024,