Distortion improvement of capsule endoscope image

被引:1
|
作者
Mang Ou-Yang [1 ]
Huang, Shih-Wei [1 ]
Chen, Yung-Lin [1 ]
Lin, Chu-Hsun [1 ]
Lin, Tai-Yung [2 ]
Kuo, Yi-Ting [3 ]
机构
[1] Natl Cent Univ, Inst Opt Sci, Chungli 320, Taiwan
[2] Chung Shan Inst Sci & Technol, Longtan Township, Taoyuan County, Taiwan
[3] Jen The Jr Coll Med Nursing & Management, Hou Loung Town, Mio Li County, Taiwan
关键词
capsule endoscope; wide-angle lens; MTF;
D O I
10.1117/12.699742
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Distortion exists in the present capsule endoscope image resulting from the confined space and the wide-angle requirement [8]. Based on the previous two lens works, the optimal design had obtained that the field of view was about 86 degrees, and MTF was about 18% at 100 1p/mm, but distortion would go to -26%. It's difficult to add another lens on the 7mm optical path between the dome and imaging lenses for improving distortion. In order to overcome this problem, we intend to design the optical dome as another optical lens. The original dome is transparent and has an equal thickness, namely without refracting light almost. Our objective in this paper is to design the inner curvature of the dome and associate two aspheric imaging lenses in front of the CMOS sensors to advance the distortion with maintaining field of view and MTF under the same capsule volume. Furthermore, the paper proposes the real object plane of intestine is nearly a curved surface rather than an ideal flat surface. Taking those reasons under consideration, we design three imaging lenses with curved object plane and obtain the field of view is about 86 degrees, MTF is about 26% at 100 1p/mm, and the distortion improve to -7.5%. Adding the dome lens is not only to enhance the image quality, but also to maintain the tiny volume requirement.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Image distortion correction for wireless capsule endoscope
    Hu, C
    Meng, M
    Liu, PXP
    Wang, X
    2004 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1- 5, PROCEEDINGS, 2004, : 4718 - 4723
  • [2] Improvement and experiment of the video capsule endoscope
    Xu, Fei
    Yan, Guo-Zheng
    Zhu, Bing-Quan
    Liu, Gang
    Lu, Li
    Tien Tzu Hsueh Pao/Acta Electronica Sinica, 2015, 43 (03): : 605 - 610
  • [3] Correction of Capsule Endoscope Image Distortion Based on Two-dimensional Look-up Table
    Yuan, Xiaoying
    Hu, Chao
    Chen, Jianke
    Feng, Zhongqing
    Wang, Yonghui
    Ren, Yupeng
    2014 11TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA), 2014, : 553 - 557
  • [4] Image Representation and Compression for Capsule Endoscope Robot
    Hu, Chao
    Meng, Max Q. -H.
    Liu, Li
    Pan, Yinzi
    Liu, Zhiyong
    ICIA: 2009 INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION, VOLS 1-3, 2009, : 491 - +
  • [5] Automatic Radial Distortion Correction for Endoscope Image
    Cong, Weijian
    Yang, Jian
    Deng, Weijiang
    Zhu, Jianjun
    2013 6TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING (CISP), VOLS 1-3, 2013, : 932 - 937
  • [6] Study on correction of distortion in medical electronic endoscope image
    Xie, HB
    Chen, DQ
    Xu, Z
    Yu, DQ
    MEDICAL IMAGE ACQUISITION AND PROCESSING, 2001, 4549 : 69 - 74
  • [7] An ultra-low-power image compressor for capsule endoscope
    Lin, Meng-Chun
    Dung, Lan-Rong
    Weng, Ping-Kuo
    BIOMEDICAL ENGINEERING ONLINE, 2006, 5 (1)
  • [8] An ultra-low-power image compressor for capsule endoscope
    Meng-Chun Lin
    Lan-Rong Dung
    Ping-Kuo Weng
    BioMedical Engineering OnLine, 5
  • [9] Image stitching and image reconstruction of intestines captured using radial imaging capsule endoscope
    Mang Ou-Yang
    Jeng, Wei-De
    Wu, Yin-Yi
    Dung, Lan-Rong
    Wu, Hsien-Ming
    Weng, Ping-Kuo
    Huang, Ker-Jer
    Chiu, Luan-Jiau
    OPTICAL ENGINEERING, 2012, 51 (05)
  • [10] Microrobots for a Capsule Endoscope
    Kim, Byungkyu
    Park, Sukho
    Park, Jong-Oh
    2009 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS, VOLS 1-3, 2009, : 729 - +