Thermal analysis of bone cement polymerisation at the cement-bone interface

被引:0
|
作者
Stanczyk, M [1 ]
van Rietbergen, B
机构
[1] Polish Acad Sci, Inst Fundamental Technol Res, Warsaw, Poland
[2] Eindhoven Univ Technol, Dept Biomed Engn, NL-5600 MB Eindhoven, Netherlands
关键词
bone cement; polymerisation; heat generation; micro-CT; finite element analysis;
D O I
10.1016/j.biomech.2004.03.002
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The two major problems that have been reported with the use of polymethylmethacrylate (PMMA) cement are thermal necrosis of surrounding bone due to the high heat generation during polymerisation and chemical necrosis due to unreacted monomer release. Computer models have been used to Study the temperature and monomer distribution after cementation. In most of these models, however, polymerisation is modelled as temperature independent and cancellous bone is modelled as a continuum. Such models thus cannot account for the expected important role of the trabecular bone micro-structure. The aim of this study is to investigate the distribution of temperature and monomer leftover at the cancellous bone-cement interface during polymerisation for a realistic trabecular bone-cement micro-structure and realistic temperature-dependent polymerisation kinetics behaviour. A 3-D computer model of a piece of bovine cancellous bone that underwent pressurization with bone-cement was generated using a micro-computed tomography scanner. This geometry was used as the basis for a finite element model and a temperature-dependent problem for bone cement polymerisation kinetics was solved to simulate the bone cement polymerisation process in the vicinity of the interface. The transient temperature field throughout the interface was calculated, along with the polymerisation fraction distribution in the cement domain. The calculations revealed that the tips of the bone trabeculae that are embedded in the cement attain temperatures much higher than the average temperature of the bone volume. A small fraction of the bone (10%) is exposed to temperatures exceeding 70degreesC, but the exposure time to these high temperatures is limited to 50 s. In the region near the bone, the cement polymerisation fraction (about 84%) is less than that in the centre (where it is reaching values of over 96%). An important finding of this study thus is the fact that the bone tissue that is subjected to the highest temperatures is also subjected to high leftover monomer concentration. Furthermore the maximum bone temperature is reached relatively early, when monomer content in the neighbouring cement is still quite high. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1803 / 1810
页数:8
相关论文
共 50 条
  • [21] Numerical modelling of cement polymerisation and thermal bone necrosis
    Starke, GR
    Birnie, C
    van den Blink, PA
    COMPUTER METHODS IN BIOMECHANICS & BIOMEDICAL ENGINEERING - 2, 1998, : 163 - 172
  • [22] A RAT MODEL OF RESORPTION OF BONE AT THE CEMENT-BONE INTERFACE IN THE PRESENCE OF POLYETHYLENE WEAR PARTICLES
    HOWIE, DW
    VERNONROBERTS, B
    OAKESHOTT, R
    MANTHEY, B
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (02): : 257 - 263
  • [23] RHEUMATOID NODULES AT THE CEMENT-BONE INTERFACE IN REVISION ARTHROPLASTY OF RHEUMATOID PATIENTS
    INOUE, K
    NISHIOKA, J
    HUKUDA, S
    SHICHIKAWA, K
    OKABE, H
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (03): : 455 - 458
  • [24] Mechanical strength of the cement-bone interface is greater in shear than in tension
    Mann, KA
    Werner, FW
    Ayers, DC
    JOURNAL OF BIOMECHANICS, 1999, 32 (11) : 1251 - 1254
  • [25] The behavior of the micro-mechanical cement-bone interface affects the cement failure in total hip replacement
    Waanders, Daan
    Janssen, Dennis
    Mann, Kenneth A.
    Verdonschot, Nico
    JOURNAL OF BIOMECHANICS, 2011, 44 (02) : 228 - 234
  • [26] RADIOGRAPHIC INTERPRETATION OF CEMENT-BONE INTERLOCK IN THE FEMUR
    KOEWEIDEN, E
    JACOBS, M
    SLOOFF, T
    VANHORN, J
    ACTA ORTHOPAEDICA SCANDINAVICA, 1988, 59 (02): : 235 - 235
  • [27] Mixed-mode loading of the cement-bone interface: a finite element study
    Waanders, Daan
    Janssen, Dennis
    Bertoldi, Katia
    Mann, Kenneth A.
    Verdonschot, Nico
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2011, 14 (02) : 145 - 155
  • [28] Finite Element Simulation of Cement-Bone Interface Micromechanics: A Comparison to Experimental Results
    Janssen, Dennis
    Mann, Kenneth A.
    Verdonschot, Nico
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2009, 27 (10) : 1312 - 1318
  • [29] The contribution of frictional torque to loosening at the cement-bone interface in Tharies hip replacements
    Mai, MT
    Schmalzried, TP
    Dorey, FJ
    Campbell, PA
    Amstutz, HC
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (04): : 505 - 511
  • [30] Modeling the tensile behavior of the cement-bone interface using nonlinear fracture mechanics
    Mann, KA
    Werner, FW
    Ayers, DC
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1997, 119 (02): : 175 - 178