Electric Field Calculations on a High Voltage Insulator under Wet Conditions

被引:5
|
作者
Sarang, B. [1 ]
Lakdawala, V. [1 ]
Basappa, P. [2 ]
机构
[1] Old Dominion Univ, Norfolk, VA 23529 USA
[2] Norfolk State Univ, Norfolk, VA USA
关键词
D O I
10.1109/EIC.2009.5166327
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Occurrence of water droplets on outdoor insulators either due to rain, fog, dew etc. leads to localized field enhancement causing partial discharges and dry arcs which ultimately results in complete flashover. Presence of a hydrophobic coating (e.g. RTV coating) inhibits the formation of water films and hence lead to formation of discrete water particles which are less dangerous. In this paper two cases are investigated. The first case refers to the hydrophobic case where water droplets reside as discrete droplets on Silicon Rubber (SIR). The second case is when water droplets coalesce and form a film due to the diminution of the hydrophobic property. The first set of simulations inquired the role of single, multiple discrete water droplets on the shed and the sheath region in enhancing the E-Field. The second set of simulations looked into effect of the water films on the shed region. A High Voltage insulator (138KV) made of SIR is considered to perform the Electric Field Calculations. The first set of results indicates that the water droplets in the sheath region greatly contribute towards enhancing the probability of initiation and progression of wet flashover on insulator surface. The second set of simulations revealed that the E-Field intensification is more when there is abatement of hydrophobic property on the SIR insulators when compared to the discrete droplets case. Simulation was done with the help of a 3D Electric Field Analysis package called COULOMB.
引用
收藏
页码:86 / +
页数:2
相关论文
共 50 条
  • [31] Measurement and simulation of the voltage distribution and the electric field on a glass insulator string
    Kontargyri, V. T.
    Plati, L. N.
    Gonos, I. F.
    Stathopulos, I. A.
    [J]. MEASUREMENT, 2008, 41 (05) : 471 - 480
  • [32] Electric Field Simulation of a Voltage Graded Type Insulator for DC GIL
    Hu, Kejie
    Cheng, Jianwei
    Wang, Shuaibing
    Chen, Xi
    Li, Zhiqiang
    Liu, Peng
    Jin, Shoufeng
    [J]. 2019 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2019, : 214 - 217
  • [33] Simulation of Voltage and Electric-Field Distribution for Contaminated Glass Insulator
    Othman, N. A.
    Piah, M. A. M.
    Adzis, Z.
    Ahmad, H.
    Ahmad, N. A.
    [J]. 2013 IEEE STUDENT CONFERENCE ON RESEARCH AND DEVELOPMENT (SCORED 2013), 2013, : 116 - 120
  • [34] Calculation of electric field and partial discharge activity reduction for covered conductor/high voltage insulator systems
    Ibrahim, Mohamed E.
    Abd-Elhady, Amr M.
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2017, 144 : 72 - 80
  • [35] Breakdown electric field investigation using the AC breakdown & simulation in insulator for ultra-high voltage
    Park, Hee-Doo
    Ahn, Byung-Chul
    Lee, Hyuk-Jin
    Shin, Jong-Yeol
    Kim, Gwi-Yeol
    Hong, Jin-Woong
    [J]. ICPASM 2005: PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 AND 2, 2006, : 514 - +
  • [36] Investigation of the Electric Field of Metallic Fence under a High Voltage Transmission Line
    Virbalis, Juozapas Arvydas
    Lukocius, Robertas
    Marciulionis, Povilas
    Nedzinskaite, Gabija
    Vaskys, Paulius
    [J]. ELEKTRONIKA IR ELEKTROTECHNIKA, 2016, 22 (06) : 22 - 27
  • [37] Ion Distribution in Saltwater under High-voltage Static Electric Field
    Gu, L.
    Chen, X. G.
    Liu, X. D.
    Liu, W.
    [J]. NATURAL RESOURCES AND SUSTAINABLE DEVELOPMENT, PTS 1-3, 2012, 361-363 : 865 - 869
  • [38] Effect of Dry Band Location on Electric Field Distribution along a Polymeric Insulator under Contaminated Conditions
    Arshad
    Nekahi, A.
    McMeekin, S. G.
    Farzaneh, M.
    [J]. 2015 50TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2015,
  • [39] Effect of RTV Coating Material on Electric Field Distribution and Voltage Profiles on Polymer Insulator under Lightning Impulse
    Jamaludin, Farah Adilah
    Ab-Kadir, Mohd Zainal Abidin
    Izadi, Mandi
    Azis, Norhafiz
    Jasni, Jasronita
    Abd Rahman, Muhammad Syahmi
    Osman, Miszaina
    [J]. 2018 34TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP 2018), 2018,
  • [40] Propagation of Creeping Discharges in Air Depending on the Electric Field Direction and Insulator Materials under Lightning Impulse Voltage
    Douar, M. A.
    Beroual, A.
    Souche, X.
    [J]. 2015 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2015, : 880 - 883