Accuracy of Implant Position Reproduction According to Exposed Length of the Scan Body during Optical Scanning: An In Vitro Study

被引:4
|
作者
Nam, Na-Eun [1 ]
Shin, Seung-Ho [1 ]
Lim, Jung-Hwa [1 ]
Lee, Bora [2 ]
Shim, June-Sung [3 ]
Kim, Jong-Eun [3 ]
机构
[1] Yonsei Univ, Coll Dent, Dept Prosthodont, BK21 FOUR Project, Yonsei Ro 50-1, Seoul 03722, South Korea
[2] Yonsei Univ, Coll Dent, Dept Dent Educ, Yonsei Ro 50-1, Seoul 03722, South Korea
[3] Yonsei Univ, Coll Dent, Dept Prosthodont, Yonsei Ro 50-1, Seoul 03722, South Korea
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 04期
关键词
digital impression; implant scan body; intraoral scanner; 4 INTRAORAL SCANNERS; MULTIPLE IMPLANTS; IMPRESSIONS; PRECISION; THERAPY;
D O I
10.3390/app11041689
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Featured Application This paper's application is in the proposal of a guideline for predicting and preventing errors that may occur during the image matching process when using Dental CAD software for implant prosthesis. The differences in the accuracy of implant position reproduction according to various types of scanners, implant placement depths, and tooth positions are presented in detail. Accuracy of implant position reproduction according to various types of scanners, implant placement depths, and tooth positions are unknown. The purpose of this study was to compare the accuracy of implant position reproduction for differences in the exposed length of the implant scan body according to scanner type and tooth position. Implants were placed at the positions of the lateral incisor, first premolar, and first molar in the study model at the bone level and submerged 1.5 mm, 3.0 mm, 4.5 mm, and 6.0 mm. The completed models were scanned with one type of tabletop scanner and three types of intraoral scanners (TRIOS 3, i500, and CS3600). A matching process was performed for all scan data to superimpose abutment library data on the scan body, and the root mean square errors were analyzed in three dimensions to evaluate the position reproducibility of the replaced abutment library. In the trueness analysis, the error increased rapidly for an implant placement depth of 4.5 mm, and was largest for a submersion of 6.0 mm. The precision analysis confirmed that the error increased for depths of at least 3.0 mm. The analysis by position identified that the accuracy was lowest for an implant placed at the position of the lateral incisor. These findings indicate that special care is required when making an impression of a deep implant with an optical scanner.
引用
收藏
页码:1 / 16
页数:16
相关论文
共 50 条
  • [1] Influence of the implant scan body bevel location, implant angulation and position on intraoral scanning accuracy: An in vitro study
    Gomez-Polo, Miguel
    Alvarez, Francisco
    Ortega, Rocio
    Gomez-Polo, Cristina
    Barmak, Abdul B.
    Kois, John C.
    Revilla-Leon, Marta
    [J]. JOURNAL OF DENTISTRY, 2022, 121
  • [2] Influence of the implant scan body bevel location, implant angulation and position on intraoral scanning accuracy: An in vitro study (vol 121, 104122, 2022)
    Gomez-Polo, Miguel
    Alvarez, Francisco
    Ortega, Rocio
    Gomez-Polo, Cristina
    Barmak, Abdul B.
    Kois, John C.
    Revilla-Leon, Marta
    [J]. JOURNAL OF DENTISTRY, 2022, 126
  • [3] Effect of supramucosal height of a scan body and implant angulation on the accuracy of intraoral scanning: An in vitro study
    Sicilia, Elena
    Lagreca, Gabriela
    Papaspyridakos, Panos
    Finkelman, Matthew
    Cobo, Juan
    Att, Wael
    Revilla-Leon, Marta
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (06): : 1126 - 1134
  • [4] The effect of scanning the palate and scan body position on the accuracy of complete-arch implant scans
    Mizumoto, Ryan M.
    Alp, Gulce
    Ozcan, Mutlu
    Yilmaz, Burak
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (05) : 987 - 994
  • [5] Effect of a Novel 'Scan Body' on the In Vitro Scanning Accuracy of Full-Arch Implant Impressions
    Zhang, Tingting
    Yang, Bo
    Ge, Ruihan
    Zhang, Chaobiao
    Zhang, Hui
    Wang, Yan
    [J]. INTERNATIONAL DENTAL JOURNAL, 2024, 74 (04) : 847 - 854
  • [6] Evaluation of the Trueness of Digital Implant Impressions According to the Implant Scan Body Orientation and Scanning Method
    Lee, Bora
    Nam, Na-Eun
    Shin, Seung-Ho
    Lim, Jung-Hwa
    Shim, June-Sung
    Kim, Jong-Eun
    [J]. APPLIED SCIENCES-BASEL, 2021, 11 (07):
  • [7] The Influence of Using Different Types of Scan Bodies on the Transfer Accuracy of Implant Position: An In Vitro Study
    Schmidt, Alexander
    Billig, Jan-Wilhelm
    Schlenz, Maximiliane A.
    Woestmann, Bernd
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2021, 34 (02) : 254 - 260
  • [8] Influence of scan body design on accuracy of the implant position as transferred to a virtual definitive implant cast
    Revilla-Leon, Marta
    Smith, Zachary
    Methani, Mohammed M.
    Zandinejad, Amirali
    Oezcan, Mutlu
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (06): : 918 - 923
  • [9] Effect of using scan body accessories and inter-implant distances on the accuracy of complete arch implant digital impressions: An in vitro study
    Ashry, Amal
    Abdelhamid, Ahmed M.
    Ezzelarab, Salah
    Khamis, Mohamed Moataz
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
  • [10] Accuracy of intraoral optical scan versus stereophotogrammetry for complete-arch digital implant impression: An in vitro study
    Pozzi, Alessandro
    Agliardi, Enrico
    Lio, Fabrizio
    Nagy, Katalin
    Nardi, Alessandra
    Arcuri, Lorenzo
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2024, 68 (01) : 172 - 180