Influence of scan body design on accuracy of the implant position as transferred to a virtual definitive implant cast

被引:24
|
作者
Revilla-Leon, Marta [1 ,2 ]
Smith, Zachary [1 ]
Methani, Mohammed M. [3 ]
Zandinejad, Amirali [1 ]
Oezcan, Mutlu [4 ]
机构
[1] Texas A&M Univ, Coll Dent, AEGD Residency, Dallas, TX USA
[2] Univ Washington, Sch Dent, Prosthodont, Seattle, WA 98195 USA
[3] Texas A&M Univ, Coll Dent, Sci Oral Biol, Dallas, TX USA
[4] Univ Zurich, Ctr Dent & Oral Med, Clin Resconstruct Dent, Div Dent Biomat, Zurich, Switzerland
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2021年 / 125卷 / 06期
关键词
IMPRESSION TECHNIQUES; FIXED PROSTHODONTICS; IN-VITRO; PRECISION; FRAMEWORKS; FIT;
D O I
10.1016/j.prosdent.2020.03.019
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Previous studies have analyzed factors influencing intraoral scanner accuracy; however, how the intraoral scan body design affects the implant position on the virtual definitive cast is unclear. Purpose. The purpose of this in vitro study was to measure the discrepancies of the implant replica positions of the virtual definitive implant cast obtained by using 3 different scan body designs when performing a digital scan. Material and methods. A partially edentulous typodont with 3 implant replicas (Implant Replica RP Branemark system; Nobel Biocare Services AG) was prepared. Three groups were determined based on the scan body system evaluated: SB-1 (Elos Accurate Nobel Biocare), SB-2 (NT Digital Implant Technology), and SB-3 (Dynamic Abutment). Each scan body was positioned on each implant replica of the typodont, and was digitized by using an intraoral scanner (iTero Element; Cadent) as per the manufacturer's scanning protocol at 1000 lux illuminance. A standard tessellation language (STL) file was obtained. Before the scan bodies were removed from the typodont, a coordinate measuring machine (CMM Contura G2 10/16/06 RDS; Carl Zeiss Industrielle Messtechnik GmbH) was used to measure the scan body positions on the x-, y-, and z-axis. The linear and angular discrepancies between the position of the scan bodies on the typodont and STL file were calculated by using the best fit technique with a specific program (Calypso; Carl Zeiss Industrielle Messtechnik GmbH). The procedure was repeated until 10 STL files were obtained per group. The Shapiro-Wilk test revealed that the data were not normally distributed. The data were analyzed by using the Mann-Whitney U test (alpha=.05). Results. The coordinate measuring machine was unable to measure the scan body positions of the magnetically retained SB-3 group because of its mobility when palpating at the smallest pressure possible. Therefore, this group was excluded. No significant differences were found in the linear discrepancies between the SB-1 and SB-2 groups (P>.05). The most accurate scan body position was obtained on the z-axis. However, the SB-1 group revealed a significantly higher XZ angular discrepancy than the SB-2 group (P<.001). Conclusions. The scan body systems tested (SB-1 and SB-2 groups) accurately transferred the linear implant positions to the virtual definitive implant cast. However, significant differences were observed in the XZ angular implant positions between the scan body systems analyzed.
引用
收藏
页码:918 / 923
页数:6
相关论文
共 50 条
  • [1] Influence of the implant scan body bevel location, implant angulation and position on intraoral scanning accuracy: An in vitro study
    Gomez-Polo, Miguel
    Alvarez, Francisco
    Ortega, Rocio
    Gomez-Polo, Cristina
    Barmak, Abdul B.
    Kois, John C.
    Revilla-Leon, Marta
    [J]. JOURNAL OF DENTISTRY, 2022, 121
  • [2] Influence of scan body design and digital implant analogs on implant replica position in additively manufactured casts
    Revilla-Leon, Marta
    Fogarty, Rachel
    Barrington, Jennifer J.
    Zandinejad, Amirali
    Ozcan, Mutlu
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (02): : 202 - 210
  • [3] Influence of Implant Angulation and Implant Number on the Accuracy of Definitive Casts
    Narayane, Abhay Kiran
    Shamsuddeen, Suhana
    Kharat, Swati
    Rashidi, Tabish
    Pandav, Aachut
    Thakur, Manoj Kumar
    [J]. JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2021, 13 (05): : 367 - 369
  • [4] Influence of the implant scan body bevel location, implant angulation and position on intraoral scanning accuracy: An in vitro study (vol 121, 104122, 2022)
    Gomez-Polo, Miguel
    Alvarez, Francisco
    Ortega, Rocio
    Gomez-Polo, Cristina
    Barmak, Abdul B.
    Kois, John C.
    Revilla-Leon, Marta
    [J]. JOURNAL OF DENTISTRY, 2022, 126
  • [5] Influence of implant angulation and clinical implant scan body height on the accuracy of complete arch intraoral digital scans
    Gomez-Polo, Miguel
    Sallorenzo, Alessandro
    Ortega, Rocio
    Gomez-Polo, Cristina
    Barmak, Abdul B.
    Att, Wael
    Revilla-Leon, Marta
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (01): : 119 - 127
  • [6] The effect of the improperly scanned scan body images on the accuracy of virtual implant positioning in computer-aided design software
    Park, Se-Won
    Choi, Yong-Do
    Lee, Du-Hyeong
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2020, 12 (03): : 107 - 113
  • [7] The effect of scanning the palate and scan body position on the accuracy of complete-arch implant scans
    Mizumoto, Ryan M.
    Alp, Gulce
    Ozcan, Mutlu
    Yilmaz, Burak
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (05) : 987 - 994
  • [8] The Influence of Using Different Types of Scan Bodies on the Transfer Accuracy of Implant Position: An In Vitro Study
    Schmidt, Alexander
    Billig, Jan-Wilhelm
    Schlenz, Maximiliane A.
    Woestmann, Bernd
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2021, 34 (02) : 254 - 260
  • [9] Influence of impression technique and material on the transfer accuracy of the implant position onto the working cast.
    Woestmann, B.
    Hassfurth, U.
    Balkenhol, M.
    Ferger, P.
    [J]. JOURNAL OF DENTAL RESEARCH, 2003, 82 : B392 - B392
  • [10] The effect of scanner type and scan body position on the accuracy of complete-arch digital implant scans
    Cakmak, Gulce
    Yilmaz, Hakan
    Trevino, Alejandro
    Kokat, Ali Murat
    Yilmaz, Burak
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (04) : 533 - 541