Influence of the connecting tube at the cold end in a U-shaped pulse tube cryocooler

被引:2
|
作者
Hu, J. Y. [1 ]
Zhang, X. Z. [1 ,2 ]
Wang, X. T. [1 ]
Luo, E. C. [1 ]
Dai, W. [1 ]
机构
[1] Chinese Acad Sci, Tech Inst Phys & Chem, Key Lab Cryogen, Beijing 100190, Peoples R China
[2] Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
关键词
In-line; U-shape; Pulse tube; Cryocooler; STIRLING-TYPE; REFRIGERATOR; ENGINE;
D O I
10.1016/j.cryogenics.2014.05.011
中图分类号
O414.1 [热力学];
学科分类号
摘要
In some special applications, the pulse tube cryocooler must be designed as U-shape; however, the connecting tube at the cold end will influence the cooling performance. Although lots of U-shape pulse tubes have been developed, the mechanism of the influence of the connecting tube on the performance has not been well demonstrated. Based on thermoacoustic theory, this paper discusses the influence of the length and diameter of the connecting tube, transition structure, flow straightener, impedance of the inertance tube, etc. on the cooling performance. Primary experiments were carried out in two in-line shape pulse tube cryocoolers to verify the analysis. The two cryocoolers shared the same regenerator, heat exchangers, inertance tube and straightener, and the pulse tube, so the influence of these components could be eliminated. With the same electric power, the pulse tube cryocooler without connecting parts obtained 31 W cooling power at 77 K; meanwhile, the other pulse tube cryocooler with the connecting parts only obtained 27W, so the connecting tube induced more than a 12.9% decrease on the cooling performance, which agrees with the calculation quite well. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:157 / 162
页数:6
相关论文
共 50 条
  • [21] Development of the miniature pulse tube cryocooler
    Matsumoto, N
    Yasukawa, Y
    Ohshima, K
    Toyama, K
    Tsukahara, Y
    Kamoshita, T
    Takeuchi, T
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS. 49A AND B, 2004, 710 : 1339 - 1346
  • [22] Pulse tube cryocooler for IR applications
    Korf, H
    Rühlich, I
    Mai, M
    Thummes, G
    Infrared Technology and Applications XXXI, Pts 1 and 2, 2005, 5783 : 164 - 168
  • [23] AIRS pulse tube cryocooler system
    Chan, CK
    Raab, J
    Eskovitz, A
    Carden, R
    Fletcher, M
    Orsini, R
    CRYOCOOLERS 9, 1997, : 895 - 903
  • [24] PULSE TUBE CRYOCOOLER DYNAMICS AND SIMULATION
    Davis, Christopher
    Sarigul-Klijn, Nesrin
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 1, 2012, : 289 - 296
  • [25] Numerical simulation study of inertance tube in the pulse tube cryocooler
    Technical Institute of Physics and Chemistry, CAS, Beijing 100080, China
    不详
    Kung Cheng Je Wu Li Hsueh Pao, 2006, SUPPL. 1 (29-32):
  • [26] Minimising flow losses within the pulse tube of a Stirling pulse tube cryocooler
    Abolghasemi, M. A.
    Stone, R.
    Dadd, M.
    Bailey, P.
    Liang, K.
    27TH INTERNATIONAL CRYOGENICS ENGINEERING CONFERENCE AND INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2018 (ICEC-ICMC 2018), 2019, 502
  • [27] Numerical and experimental study of partly tapered pulse tube in a pulse tube cryocooler
    Yan, Cungang
    Zhang, Yibing
    Qiu, Jian
    Chen, Yanyan
    Wang, Xiaotao
    Dai, Wei
    Ma, Mingtao
    Li, Haibing
    Luo, Ercang
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 120 : 474 - 480
  • [28] Modelling and analysis of parameters of vacuum tube solar collector with U-shaped tube for different climates
    Smaisim, Ghassan Fadhil
    Abed, Azher M.
    Hadrawi, Salema K.
    Jahanbin, Farnaz
    CLEAN ENERGY, 2023, 7 (03): : 519 - 531
  • [29] Influence of the cold end heat exchanger geometry on the pulse tube cooler performance
    Wang, Xiao-Tao (xtwang@mail.ipc.ac.cn), 1600, Science Press (37):
  • [30] Influence of minor geometric features on Stirling pulse tube cryocooler performance
    Fang, T.
    Spoor, P. S.
    Ghiaasiaan, S. M.
    Perrella, M.
    ADVANCES IN CRYOGENIC ENGINEERING, 2017, 278