Influence of the connecting tube at the cold end in a U-shaped pulse tube cryocooler

被引:2
|
作者
Hu, J. Y. [1 ]
Zhang, X. Z. [1 ,2 ]
Wang, X. T. [1 ]
Luo, E. C. [1 ]
Dai, W. [1 ]
机构
[1] Chinese Acad Sci, Tech Inst Phys & Chem, Key Lab Cryogen, Beijing 100190, Peoples R China
[2] Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
关键词
In-line; U-shape; Pulse tube; Cryocooler; STIRLING-TYPE; REFRIGERATOR; ENGINE;
D O I
10.1016/j.cryogenics.2014.05.011
中图分类号
O414.1 [热力学];
学科分类号
摘要
In some special applications, the pulse tube cryocooler must be designed as U-shape; however, the connecting tube at the cold end will influence the cooling performance. Although lots of U-shape pulse tubes have been developed, the mechanism of the influence of the connecting tube on the performance has not been well demonstrated. Based on thermoacoustic theory, this paper discusses the influence of the length and diameter of the connecting tube, transition structure, flow straightener, impedance of the inertance tube, etc. on the cooling performance. Primary experiments were carried out in two in-line shape pulse tube cryocoolers to verify the analysis. The two cryocoolers shared the same regenerator, heat exchangers, inertance tube and straightener, and the pulse tube, so the influence of these components could be eliminated. With the same electric power, the pulse tube cryocooler without connecting parts obtained 31 W cooling power at 77 K; meanwhile, the other pulse tube cryocooler with the connecting parts only obtained 27W, so the connecting tube induced more than a 12.9% decrease on the cooling performance, which agrees with the calculation quite well. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:157 / 162
页数:6
相关论文
共 50 条
  • [1] Experimental study of the connecting tube at the cold end of a U-shaped pulse tube cryocooler
    Hu, J. Y.
    Zhang, X. Z.
    Chen, Y. Y.
    Zhang, L. M.
    Luo, E. C.
    CRYOGENICS, 2015, 72 : 77 - 81
  • [2] Experimental study of the connecting tube at the cold end in a u-shaped pulse tube cyocooler
    Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing
    100190, China
    不详
    100049, China
    Kung Cheng Je Wu Li Hsueh Pao, 4 (724-727):
  • [3] Theoretical analysis on the influence of the cold end connecting tube in a U-type pulse tube cryocooler
    Huang, Taihe
    Chen, Houlei
    Cai, Jinghui
    PROCEEDINGS OF THE 25TH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE AND INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2014, 2015, 67 : 497 - 502
  • [4] A pulse tube cryocooler with a cold reservoir
    Zhang, X. B.
    Zhang, K. H.
    Qiu, L. M.
    Gan, Z. H.
    Shen, X.
    Xiang, S. J.
    CRYOGENICS, 2013, 54 : 30 - 36
  • [5] IN-PLANE BENDING OF A U-SHAPED CIRCULAR TUBE WITH END CONSTRAINTS
    THAILER, HJ
    CHENG, DH
    JOURNAL OF ENGINEERING FOR INDUSTRY, 1970, 92 (04): : 792 - &
  • [6] IN-PLANE BENDING OF A U-SHAPED CIRCULAR TUBE WITH END CONSTRAINTS
    THAILER, HJ
    CHENG, DH
    MECHANICAL ENGINEERING, 1970, 92 (12) : 57 - &
  • [7] Investigation on a three-cold-finger pulse tube cryocooler
    Tang Qingjun
    Chen Houlei
    Cai Jinghui
    CRYOGENICS, 2015, 70 : 65 - 69
  • [8] A new structural U-shape pulse tube cryocooler
    Yin, Chuan-Lin
    Chen, Hou-Lei
    Cai, Jing-Hui
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2012, 33 (09): : 1479 - 1482
  • [9] High frequency pulse tube cryocooler with nonmetallic cold head
    Xun, Y. Q.
    Dai, Q. T.
    Yang, L. W.
    Liang, J. T.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (01): : 279 - 284