Cross-track infrared sounder FPAA performance

被引:2
|
作者
Masterjohn, S [1 ]
D'Souza, AI [1 ]
Dawson, LC [1 ]
Dolan, P [1 ]
Wijewarnasuriya, PS [1 ]
Ehlert, J [1 ]
机构
[1] DRS Sensors & Targeting Syst, Anaheim, CA 92806 USA
关键词
D O I
10.1117/12.453568
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The Cross-track Infrared Sounder (CrIS) is one of many instruments that comprise the National Polar-orbiting Operational Environmental Satellite System (NPOESS). The CrIS instrument is a Michelson interferometer-based. sensor that is sensitive to wavelengths between 3.5 and 16 microns. Three separate Focal Plane Array Assemblies (FPAAs) referred to as the Short Wave Infrared Assembly (SWIR, lambda(c) similar to 5 mum at 98 K), the Mid Wave Infrared assembly (MWIR, lambda(c) similar to 9 mum at 98 K), and the Long Wave Infrared assembly (LWIR, lambda(c) similar to 16 mum at 81 K) are used to span the spectral range. The CrIS instrument measures the earth radiance at high spectral resolution using the data to provide pressure, temperature and moisture profiles of the atmosphere. The CrIS instrument will help improve both global and regional predictions of weather patterns, storm tracks, and precipitation. The CrIS program selected photovoltaic (PV) detectors for use in all three spectral bands. PV technology outperforms photoconductive detectors in terms of high sensitivity and linearity. Each FPAA consists of a 3x3 detector-matrix that are used to form 9 fields of view (FOV). Each detector has a 1,000 gm active area diameter and has its own cold preamplifier, warm post amplifier and independent high pass filter. This paper describes the performance for all three assemblies that together form the basis of the CrIS Engineering Development Unit 2 (EDU2) Detector Preamp Module (DPM).
引用
收藏
页码:368 / 379
页数:12
相关论文
共 50 条
  • [21] Cross-Track Infrared Sounder Spectral Gap Filling Toward Improving Intercalibration Uncertainties
    Xu, Hui
    Chen, Yong
    Wang, Likun
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2019, 57 (01): : 509 - 519
  • [22] Impacts of field of view configuration of Cross-track Infrared Sounder on clear-sky observations
    Wang, Likun
    Chen, Yong
    Han, Yong
    APPLIED OPTICS, 2016, 55 (25) : 7113 - 7119
  • [23] Global decadal measurements of methanol, ethene, ethyne, and HCN from the Cross-track Infrared Sounder
    Wells, Kelley C.
    Millet, Dylan B.
    Brewer, Jared F.
    Payne, Vivienne H.
    Cady-Pereira, Karen E.
    Pernak, Rick
    Kulawik, Susan
    Vigouroux, Corinne
    Jones, Nicholas
    Mahieu, Emmanuel
    Makarova, Maria
    Nagahama, Tomoo
    Ortega, Ivan
    Palm, Mathias
    Strong, Kimberly
    Schneider, Matthias
    Smale, Dan
    Sussmann, Ralf
    Zhou, Minqiang
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2025, 18 (03) : 695 - 716
  • [24] Retrieval of Carbon Dioxide Using Cross-Track Infrared Sounder (CrIS) on S-NPP
    Zhang, Xinxin
    Zhang, Ying
    Bai, Lu
    Tao, Jinhua
    Chen, Liangfu
    Zou, Mingmin
    Han, Zongfu
    Wang, Zhibao
    REMOTE SENSING, 2021, 13 (06)
  • [25] Methodology and Information Content of the NOAA NESDIS Operational Channel Selection for the Cross-Track Infrared Sounder (CrIS)
    Gambacorta, Antonia
    Barnet, Christopher D.
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2013, 51 (06): : 3207 - 3216
  • [26] Satellite measurements of peroxyacetyl nitrate from the Cross-Track Infrared Sounder: comparison with ATom aircraft measurements
    Payne, Vivienne H.
    Kulawik, Susan S.
    Fischer, Emily V.
    Brewer, Jared F.
    Huey, L. Gregory
    Miyazaki, Kazuyuki
    Worden, John R.
    Bowman, Kevin W.
    Hintsa, Eric J.
    Moore, Fred
    Elkins, James W.
    Juncosa Calahorrano, Julieta
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2022, 15 (11) : 3497 - 3511
  • [27] Characterization of Long-Term Stability of Suomi NPP Cross-Track Infrared Sounder Spectral Calibration
    Chen, Yong
    Han, Yong
    Weng, Fuzhong
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2017, 55 (02): : 1147 - 1159
  • [28] Proton irradiations of large area Hg1-xCdxTe photovoltaic detectors for the cross-track infrared sounder
    Kelly, MW
    Ringdahl, EJ
    D'Souza, AI
    Luce, SD
    Cascio, EW
    INFRARED TECHNOLOGY AND APPLICATIONS XXV111, PTS 1 AND 2, 2003, 4820 : 479 - 490
  • [29] Assessment and Correction of View Angle Dependent Radiometric Modulation due to Polarization for the Cross-Track Infrared Sounder (CrIS)
    Taylor, Joe K.
    Revercomb, Henry E.
    Tobin, David C.
    Knuteson, Robert O.
    Loveless, Michelle L.
    Malloy, Rebecca
    Suwinski, Lawrence
    Iturbide-Sanchez, Flavio
    Chen, Yong
    White, Glen
    Predina, Joe
    Johnson, David G.
    REMOTE SENSING, 2023, 15 (03)
  • [30] An initial assessment of observations from the Suomi-NPP satellite: data from the Cross-track Infrared Sounder (CrIS)
    Smith, Andrew
    Atkinson, Nigel
    Bell, William
    Doherty, Amy
    ATMOSPHERIC SCIENCE LETTERS, 2015, 16 (03): : 260 - 266