Distribution Characteristics of Airborne Bacteria and Fungi in the General Hospitals of Korea

被引:81
|
作者
Kim, Ki Youn [1 ]
Kim, Yoon Shin [1 ]
Kim, Daekeun [2 ]
机构
[1] Hanyang Univ, Inst Ind & Environm Med, Seoul 133791, South Korea
[2] Seoul Natl Univ Technol, Dept Environm Engn, Seoul, South Korea
关键词
General hospital; Korea; Airborne bacteria; Airborne fungi; Size distribution; INTENSIVE-CARE-UNIT; SERRATIA-MARCESCENS; INVASIVE ASPERGILLOSIS; PUBLIC BUILDINGS; INFECTION; INDOOR; EPIDEMIOLOGY; ENVIRONMENT; OUTBREAK; ROOMS;
D O I
10.2486/indhealth.48.236
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The objective of this study is to provide fundamental data related to size-based characteristics of bioaerosol distributed in the general hospital. Measurement sites are main lobby, ICU, surgical ward and biomedical laboratory and total five times were sampled with six-stage cascade impactor. Mean concentrations of airborne bacteria and fungi were the highest in main lobby as followed by an order of surgical ward, ICU and biomedical laboratory. The predominant genera of airborne bacteria identified in the general hospital were Staphylococcus spp. (50%), Micrococcus spp. (15-20%), Corynebacterium spp. (5-20%), and Bacillus spp. (5-15%). On the other hand, the predominant genera of airborne fungi identified in the general hospital were Cladosporium spp. (30%), Penicillium spp. (20-25%), Aspergillus spp. (15-20%), and Alternaria spp. (10-20%). The detection rate was generally highest on stage 5 (1.1-2.1 mu m) for airborne bacteria and on stage 1 (>7.0 mu m) for airborne fungi.
引用
收藏
页码:236 / 243
页数:8
相关论文
共 50 条
  • [41] Distribution of airborne microorganisms in yellow sands of Korea
    Choi, DS
    Park, YK
    Oh, SK
    Yoon, HJ
    Kim, JC
    Seo, WJ
    Cha, SH
    JOURNAL OF MICROBIOLOGY, 1997, 35 (01) : 1 - 9
  • [42] Wintertime sources and distribution of airborne lead in Korea
    Mishra, VK
    Kim, KH
    Kang, CH
    Choi, KC
    ATMOSPHERIC ENVIRONMENT, 2004, 38 (17) : 2653 - 2664
  • [43] Airborne bacteria and fungi associated with waste-handling work
    Park, Donguk
    Ryu, Seunghun
    Kim, Shinbum
    Byun, Hyaejeong
    Yoon, Chungsik
    Lee, Kyeongmin
    INTERNATIONAL JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 2013, 19 (04) : 311 - 318
  • [44] Airborne microbiological characteristics in public buildings of Korea
    Kim, Ki Youn
    Kim, Chi Nyon
    BUILDING AND ENVIRONMENT, 2007, 42 (05) : 2188 - 2196
  • [45] DETECTION OF AIRBORNE PSYCHROTROPHIC BACTERIA AND FUNGI IN FOOD STORAGE REFRIGERATORS
    Altunatmaz, Sema Sandikci
    Issa, Ghassan
    Aydin, Ali
    BRAZILIAN JOURNAL OF MICROBIOLOGY, 2012, 43 (04) : 1436 - 1443
  • [46] Enumeration of airborne bacteria and fungi using solid phase cytometry
    Vanhee, Lies M. E.
    Nelis, Hans J.
    Coenye, Tom
    JOURNAL OF MICROBIOLOGICAL METHODS, 2008, 72 (01) : 12 - 19
  • [47] AIRBORNE PARTICULATE MATTER, FUNGI, BACTERIA AND ENDOTOXINS IN FUR FARMING
    SCHIMBERG, RW
    UITTI, J
    KOTIMAA, M
    SARANTILA, R
    STAUB REINHALTUNG DER LUFT, 1992, 52 (12): : 457 - 460
  • [48] Variation of correlations between factors and culturable airborne bacteria and fungi
    Gao, Min
    Yan, Xu
    Qiu, Tianlei
    Han, Meilin
    Wang, Xuming
    ATMOSPHERIC ENVIRONMENT, 2016, 128 : 10 - 19
  • [49] Characterization of airborne fungi present in two hospitals in Kabale district - Uganda
    Odebode, A.
    Nimawanya, G.
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2020, 101 : 392 - 393
  • [50] Indoor distribution characteristics of airborne bacteria in pig buildings as influenced by season and housing type
    Kim, Ki Youn
    Ko, Han Jong
    ASIAN-AUSTRALASIAN JOURNAL OF ANIMAL SCIENCES, 2019, 32 (05): : 742 - 747