摘要
The objective of this study is to provide fundamental data related to size-based characteristics of bioaerosol distributed in the general hospital. Measurement sites are main lobby, ICU, surgical ward and biomedical laboratory and total five times were sampled with six-stage cascade impactor. Mean concentrations of airborne bacteria and fungi were the highest in main lobby as followed by an order of surgical ward, ICU and biomedical laboratory. The predominant genera of airborne bacteria identified in the general hospital were Staphylococcus spp. (50%), Micrococcus spp. (15-20%), Corynebacterium spp. (5-20%), and Bacillus spp. (5-15%). On the other hand, the predominant genera of airborne fungi identified in the general hospital were Cladosporium spp. (30%), Penicillium spp. (20-25%), Aspergillus spp. (15-20%), and Alternaria spp. (10-20%). The detection rate was generally highest on stage 5 (1.1-2.1 mu m) for airborne bacteria and on stage 1 (>7.0 mu m) for airborne fungi.
引用
收藏
页码:236 / 243
页数:8
相关论文
共 50 条
  • [1] Distribution characteristics of airborne bacteria and fungi in the feedstuff-manufacturing factories
    Kim, Ki-Youn
    Kim, Hyeon-Tae
    Kim, Daekeun
    Nakajima, Jun
    Higuchi, Takashi
    JOURNAL OF HAZARDOUS MATERIALS, 2009, 169 (1-3) : 1054 - 1060
  • [2] Assessment of airborne bacteria and fungi in pig buildings in Korea
    Kim, Ki Youn
    Ko, Han Jong
    Kim, Hyeon Tae
    Kim, Chi Nyon
    Kim, Yoon Shin
    BIOSYSTEMS ENGINEERING, 2008, 99 (04) : 565 - 572
  • [3] Exposure Level and Distribution Characteristics of Airborne Bacteria and Fungi in Seoul Metropolitan Subway Stations
    Kim, Ki Youn
    Kim, Yoon Shin
    Kim, Daekeun
    Kim, Hyeon Tae
    INDUSTRIAL HEALTH, 2011, 49 (02) : 242 - 248
  • [4] Monitoring of Airborne Fungi in Two General Hospitals in Shiraz, Southern Iran
    Pakshir, K.
    Shekarkhar, G.
    Mostagnie, S.
    Sabayan, B.
    Vaghefikia, A.
    IRANIAN JOURNAL OF MEDICAL SCIENCES, 2007, 32 (04) : 240 - 244
  • [5] Distribution characteristics and noncarcinogenic risk assessment of culturable airborne bacteria and fungi during winter in Xinxiang, China
    Xu Yan
    Dezhi Qiu
    Shikan Zheng
    Jie Yang
    Hongyan Sun
    Yue Wei
    Jingru Han
    Jianhui Sun
    Xianfa Su
    Environmental Science and Pollution Research, 2019, 26 : 36698 - 36709
  • [6] Distribution characteristics and noncarcinogenic risk assessment of culturable airborne bacteria and fungi during winter in Xinxiang, China
    Yan, Xu
    Qiu, Dezhi
    Zheng, Shikan
    Yang, Jie
    Sun, Hongyan
    Wei, Yue
    Han, Jingru
    Sun, Jianhui
    Su, Xianfa
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2019, 26 (36) : 36698 - 36709
  • [7] Diurnal distribution of airborne bacteria and fungi in the atmosphere of Helwan area, Egypt
    Hameed, A. A. Abdel
    Khoder, M. I.
    Yuosra, S.
    Osman, A. M.
    Ghanem, S.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2009, 407 (24) : 6217 - 6222
  • [8] Characteristics of airborne bacteria and fungi in some Polish wastewater treatment plants
    Kowalski, M.
    Wolany, J.
    Pastuszka, J. S.
    Plaza, G.
    Wlazlo, A.
    Ulfig, K.
    Malina, A.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2017, 14 (10) : 2181 - 2192
  • [9] Characteristics of airborne bacteria and fungi in some Polish wastewater treatment plants
    M. Kowalski
    J. Wolany
    J. S. Pastuszka
    G. Płaza
    A. Wlazło
    K. Ulfig
    A. Malina
    International Journal of Environmental Science and Technology, 2017, 14 : 2181 - 2192
  • [10] Distribution of Airborne Bacteria and Fungi in the Korean High-speed Train Indoor
    Kwon, Soon-Bark
    Cho, Youngmin
    Park, Duck-Shin
    Park, Jaehyung
    Kim, Ki-Youn
    Kim, Changsoo
    EPIDEMIOLOGY, 2011, 22 (01) : S43 - S43